Instrukcja obsługi JUNG ME5232MS


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG ME5232MS (4 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
Centre plate with memory function and sensor connection
Blinds Management
Centre plate with memory function and sensor connection
Art. No. : ..5232 MS..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
3 Function
Intended use
- Operation of electrically-driven blinds and shutters
- Operation on control of the Venetian blind control system
Product characteristics
- One Up and Down travelling time can be saved respectively for daily execution
- Buzzer for signalling
- Evaluation of a sun sensor
- Brightness threshold 20,000 lx
1/4
32518613
J:0082518613 20.05.2014
Operating modes
Memory mode:
- The saved Up and Down travelling times are executed in a 24-hour cycle.
- A signal tone sounds when the button is pressed.
iNo signal tone sounds when activating via an extension.
Push-button mode:
- The saved travelling times are not executed.
- No signal tone sounds when the button is pressed.
Sun protection function
The connection of a sun sensor enables automatic shading when it is very bright outside. If the
measured brightness exceeds the brightness threshold for more than 2 minutes, the blind
moves downwards and stops as soon as the sun sensor is shaded.
iThe sun protection function is only activated if the Venetian blind has been moved to the
upper end position and the control has deactivated automatically after 2 minutes. Each
manual operation deactivates the sun protection.
If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves
back to the upper end position.
Behaviour after a mains voltage failure
- A mains voltage failure that lasts less than 30 minutes causes the saved travelling times to
be delayed by the duration of the power failure.
- After a mains voltage failure lasting longer than 30 minutes, both saved travelling times are
deleted. After mains voltage return, the memory mode is active.
4 Operation
Moving the Venetian blind
oPress top or bottom of cover for one to 3.5 seconds.
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
Adjusting the slats
oPress top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.
Changing operating mode
oPress top or bottom of cover for 8 to 12 seconds.
After 2 seconds, several short signal tones are sounded and a long continuous tone of
1.5 seconds.
After a further 3 seconds, the operating mode switches over and the new operating mode
is signalled:
4 short signal tones = memory mode
1-second continuous tone = push-button mode
Saving travelling times
The travelling times can be saved in push-button mode or memory mode. Only the current time
can ever be saved as travelling time
oPress top of cover for 3.5 to 8 seconds to save the Up travelling time or press bottom of
cover to save the Down travelling time.
After 2 seconds, several short signal tones are sounded and a long continuous tone of
1.5 seconds.
Once the continuous tone begins, the travelling time is saved. Any existing value will be
overwritten.
iIt is also possible to only save an Up or Down travelling time.
2/4
32518613
J:0082518613 20.05.2014
Blinds Management
Centre plate with memory function and sensor connection
Deleting all travelling times
oPress top or bottom of cover for longer than 12 seconds.
After 2 seconds, several short signal tones are sounded and a long continuous tone of
1.5 seconds.
Then the operating mode is signalled.
After about 12 seconds, a 3-second long continuous tone begins.
Once the continuous tone begins, the travelling times are deleted and the cover is in
memory mode.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
Mounting and connecting
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
The Venetian blind control is mounted and connected properly (see instructions for the relevant
Venetian blind control).
oIf necessary, install sun sensor and connect to terminal block (see instructions for the
sensors and control).
iConnect the sun sensor with the correct polarity. If a sensor is connected with reversed
polarity, this will result in malfunctions. It might not be possible to operate the cover any
more.
oMount cover (3) with frame (2) onto the Venetian blind control (1) (figure 1).
6 Appendix
6.1 Technical data
Ambient temperature 0 ... +45 °C
Storage/transport temperature -10 ... +60 °C
Switch-over time for direction change approx. 1 s
Moving time approx. 120 s
Data according to EN 60730-1
Action 1.B
Degree of soiling 2
Meas. surge vol. 4000 V
SELV limit value DC 12 V
6.2 Accessories
Sunlight / dawn sensor Art. No. 32 SD
Extension flex Art. No. 32 K
6.3 Warranty
We reserve the right to make technical and formal changes to the product in the interest of
technical progress.
We provide a warranty as provided for by law.
Please send the device with a description of the defect to our central customer service office.
3/4
32518613
J:0082518613 20.05.2014
Blinds Management
Centre plate with memory function and sensor connection


Specyfikacje produktu

Marka: JUNG
Kategoria: nieskategoryzowany
Model: ME5232MS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG ME5232MS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany JUNG

JUNG

JUNG ES1565.07 Instrukcja

27 Września 2024
JUNG

JUNG CD1561.07 Instrukcja

27 Września 2024
JUNG

JUNG A1751B Instrukcja

27 Września 2024
JUNG

JUNG GCR1561.07F Instrukcja

27 Września 2024
JUNG

JUNG LS5232T3LG Instrukcja

27 Września 2024
JUNG

JUNG A5232MSAL Instrukcja

27 Września 2024
JUNG

JUNG MALS1082 Instrukcja

27 Września 2024
JUNG

JUNG ME5232MS Instrukcja

27 Września 2024
JUNG

JUNG SL5232MS Instrukcja

27 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024