Universal 2-gang dimmer insert
Light Management
Universal 2-gang dimmer insert
Art.-No.: 1252 UDE
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Do not operate the device without a cover.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Fire hazard. For operation with inductive transformers, each transformer must be fused
on the primary side in accordance with the manufacturer's instructions. Only safety
transformers according to EN 61558-2-6 may be used.
Exchange defective load on output a1 immediately, because the overheating protection
is no longer provided when the load is defective. Device can be damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Dimmer
(2) Frame
(3) Cover (see chapter 6.3. Accessories)
(4) Screw terminals
1/6
82562423
J:0082562423 16.11.2011
3 Function
Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive
transformers or Tronic transformers with halogen lamps
- Suitable for mixed load up to the specified output (see chapter 6.1. Technical data)
- Suitable for luminaire groups via the two independent outputs and a1 a2
- Installation in appliance box to DIN 49073
- Operation with suitable cover (see chapter 6.3. Accessories)
i No mixed-load operation of Tronic and inductive transformers on the same output.
Product characteristics
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Bulb-preserving soft start
- Power extension through power boosters (see power booster instructions)
- Different load types are possible on the two outputs
- Asymmetric load distribution possible
- Automatic setting of the dimming principle suitable for the load
- Connection of more than one 2-wire extension is possible (see Accessories section)
i The connection of installation buttons as extensions is not possible. This will not function.
Load type Electrical behaviour Dimming principle
Incandescent lamps ohmic Phase cut-off
HV halogen lamps ohmic Phase cut-off
Tronic transformers with
halogen lamps
capacitive Phase cut-off
Dimmable inductive
transformers with halogen
lamps
inductive Phase cut-on
i Flickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. Brief flickering upon load detection of
ohmic loads. No operation is possible during load detection. These are not device faults.
4 Operation
Figure 2: Operating sections of the button
2/6
82562423
J:0082562423 16.11.2011
Light Management
Universal 2-gang dimmer insert
The button field is subdivided into two areas:
- Left: operation of output . a1
- Right: operation of output . a2
i A 2-wire extension is always used to operate both outputs simultaneously.
Switching on the light
o Press button at top for less than 0.4 seconds.
i The light is switched on using the stored switch-on brightness.
Switching the light off
o Press button at bottom for less than 0.4 seconds.
Adjust the brightness
Light is switched on.
o Press up or down button until the desired brightness is reached.
Switching the light on with minimum brightness.
Light is switched off.
o Press button at bottom for longer than 0.4 seconds.
Save switch-on brightness
i Separate switch-on brightnesses can be saved for outputs and . In the state as a1 a2
supplied the maximum switch-on brightness is saved.
Light is switched on.
o Set light to the required brightness.
o Press button for longer than 3 seconds.
Switch-on brightness is saved.
The lighting switches briefly off and on again as confirmation.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
CAUTION!
Do not connect outputs together.
Operating both outputs on a common load will destroy the device.
For power extension use power boosters
3/6
82562423
J:0082562423 16.11.2011
Light Management
Universal 2-gang dimmer insert


Specyfikacje produktu

Marka: JUNG
Kategoria: nieskategoryzowany
Model: ES1565.07

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG ES1565.07, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany JUNG

JUNG

JUNG ES1565.07 Instrukcja

27 Września 2024
JUNG

JUNG CD1561.07 Instrukcja

27 Września 2024
JUNG

JUNG A1751B Instrukcja

27 Września 2024
JUNG

JUNG GCR1561.07F Instrukcja

27 Września 2024
JUNG

JUNG LS5232T3LG Instrukcja

27 Września 2024
JUNG

JUNG A5232MSAL Instrukcja

27 Września 2024
JUNG

JUNG MALS1082 Instrukcja

27 Września 2024
JUNG

JUNG ME5232MS Instrukcja

27 Września 2024
JUNG

JUNG SL5232MS Instrukcja

27 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024