Strona 1/84

ePump™ Series
Pumps
ENGLISH | FRANÇAIS | ESPAÑOL
WARNING
INSTALLATION AND
OPERATION MANUAL
H0365700 RevE
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that
all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning
notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper
installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage,
or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/operator of this
equipment.

Table of Contents
Section 1. IMPORTANT SAFETY INSTRUCTIONS 3
1.1 Safety Instructions 3 ................................
1.2 Pool Pump Suction Entrapment
Prevention Guidelines 5 ..........................
Section 2. General Description 6 .............................
2.1 Introduction ........................................... 6
2.2 Description ............................................ 6
Section 3. Installation Information 7 .......................
3.1 Plumbing ............................................... 7
3.2 Electrical Installation 9 .............................
3.3 ePump Dip Switch Settings .................. 11
3.4 Pressure Testing ................................... 11
3.5 Conducting Pressure Test..................... 13
3.6 Auxiliary Load Operation 13 ......................
Section 4. Operation 15 ..............................................
4.1 Start-up ................................................. 15
Section 5. Service and Maintenance 15 ....................
5.1 Routine Maintenance 15 ............................
5.2 Winterizing the Pump 16 ...........................
Section 6. Troubleshooting and Repair 17 ...............
6.1 Troubleshooting .................................... 17
6.2 Service Technician Maintenance .......... 19
Section 7. Product Specications and Technical
Data 24 .......................................................
7.1 Replacement Parts List and Exploded
View 24 ......................................................
7.2 Performance Curves 26 .............................
7.3 Physical and Operational
Specications ....................................... 26
7.4 Replacement Motor Guide 27 ....................
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Page 2
Jandy® Pro Series ePump™ Series Pump | Installation and Operation Manual
ENGLISH

Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS
INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not
use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certied to the latest
published edition of ANSI/ASME A112.19.8, or its successor standard ANSI/APSP-16.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide,
or full ow) valve position with the pump running.
WARNING
Jandy Pro Series Pumps are powered by a high-voltage electric motor and must be installed by a
licensed or certied electrician or a qualied swimming pool service technician.
WARNING
Due to the potential risk of re, electric shock, or injuries to persons, Jandy Pro Series Pumps must be
installed in accordance with the National Electrical Code ® (NEC®), all local electrical and safety codes, and
the Occupational Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National
Fire Protection Association, 470 Atlantic Ave., Boston, MA 02210, or from your local government inspection
agency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect system to an unregulated city water system or other external source of pressurized
water producing pressures greater than 35 PSI.
• Trapped air in the system can cause the lter lid to be blown off, which can result in death, serious
personal injury, or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch
circuit that is protected by a ground-fault circuit-interrupter (GFCI). Contact a qualied electrician if you
cannot verify that the circuit is protected by a GFCI. Make sure such a GFCI should be provided by
the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate
in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button
being pushed, a ground current is owing, indicating the possibility of electrical shock. Do not use the
device. Disconnect the device and have the problem corrected by a qualied service representative
before using.
Page 3
ENGLISH
Jandy
®
Pro Series ePump™ Series Pump | Installation and Operation Manual

At Least
3 Feet
Suction Outlet
(Main Drain)
Suction Outlet
(Main Drain)
No valves between
Tee and Main Drains
Listed/certified to the latest
published version of
ANSI/ASME A112.19.8,
or its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened to
Main Drain Sump
Listed/certified to the latest
published version of
ANSI®/ASME® A112.19.8,
or its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened to
Main Drain Sump
Valves OK between
pump and Tee
Pump
Figure 1. Number of Suction Outlets Per Pump
Section 2. General Description
2.1 Introduction
This manual contains information for the proper
installation, operation, and maintenance of Jandy
Pro Series ePump Series variable-speed pumps.
Procedures in this manual must be followed exactly.
To obtain additional copies of this manual, contact
Zodiac® Customer Support at 800.822.7933 or visit our
website at www.zodiacpoolsystems.com. For address
information, see the back cover of this manual.
2.2 Description
The ePump is a variable-speed pump that can be
run from 600 RPM to 3450 RPM. When connected to
the Jandy Pro Series ePump controller, up to eight (8)
speed settings may be programmed and recalled. This
allows you to select the most appropriate speed for
your application. Even more versatile programming is
possible when you use a Jandy Pro Series AquaLink®
RS controller.
The Jandy Pro Series ePump is designed to meet
the needs of today’s more hydraulically demanding
pool equipment. The pump housing, backplate, diffuser,
impeller, and hair and lint pot (pump debris filter
basket) are all made from high quality thermoplastic
materials. These materials were chosen for their strength
and corrosion resistance.
The pump is driven by an electric motor directly
attached to the pump impeller. As the electric motor
turns, it causes the impeller to turn, which forces water
to flow through the pump. The water flows through the
pump inlet and then into the filter basket. The basket
assembly pre-strains/traps large particles. The water
then enters the center of the pump housing, flows
through the impeller into the diffuser, and flows out the
pump discharge port.
Page 6
Jandy®
Pro Series ePump™ Series Pump | Installation and Operation Manual
ENGLISH

4. The pump should be installed on a firm, solid, and
level surface to avoid risk of settlement. Do not use
sand to level the pump as sand will wash away. Check
local building codes for any additional requirements
(Ex. Equipment pads in Florida must be concrete and
equipment must be secured to the pad.)
NOTE Zodiac Pool Systems, Inc. recommends bolting
the pump directly to the foundation.
5. The pump foundation must have adequate drainage
to prevent the motor from getting wet. Protect the
pump from the rain and sun.
6. Proper ventilation is required for the pump to operate
normally. All motors generate heat that must be
removed by providing proper ventilation.
7. Provide access for future services by leaving a clear
area around the pump. Allow plenty of space above
the pump to remove the lid and basket for cleaning.
8. If the equipment is in a potentially dark area, provide
adequate lighting.
3.1.3 Pipe Sizing
NOTE All HP ratings given in this section apply to full-
rated pumps.
3.1.3.1 Suction Pipe
When the pump is located up to 50 feet from the
pool, the recommended minimum pipe size for the
suction side of the pump is 2" for .75 to 1.5 HP*. For
2.0 HP* pumps, the recommended pipe size is 2 ½". For
3.0 HP* pumps, the recommended pipe size is 3".
* HP refers to full rated pumps.
3.1.3.2 Discharge Pipe
When the pump is located up to 50 feet from the
pool, the recommended minimum pipe size for the
discharge side of the pump is 2" for .75 to 1.5 HP*. For
2.0 HP* pumps, the recommended pipe size is 2½". For
3.0 HP* pumps, the recommended pipe size is 3".
* HP refers to full rated pumps.
NOTE All pipe sizes are able to withstand the
pressures the pump will deliver, but not
necessarily the flow. If the pipe is too small
for the pump, or is elevated above water, the
maximum gallons per minute (GPM) may not be
delivered. If this happens, the pump will develop
a pocket of air (cavitation) that makes noise.
This may shorten the life of the pump.
3.1.3.3 Installation Recommendations
1. If the pump is located below water level, isolation
valves must be installed on both sides of the pump
to prevent the back flow of pool water during any
routine or required servicing.
Section 3. Installation Information
3.1 Plumbing
3.1.1 Preparation Information
1. Upon receipt of the pump, check the carton for
damage. Open the carton and check the pump for
concealed damage, such as cracks, dents or a bent
base. If damage is found, contact the shipper or
distributor where the pump was purchased.
2. Inspect the contents of the carton and verify
that all parts are included. See Section 7.1,
Replacement Parts List and Exploded View.
3.1.2 Pump Location
CAUTION
For Canadian installation, this pump carries a Type
3R enclosure rating and therefore is not intended for
installation in areas subjected to windblown dust.
1. Zodiac recommends installing the pump within one
(1) foot above water level. Refer to Figure 2 for a
typical installation. The pump should not be elevated
more than a few feet above the water level of the
pool. A check valve is recommended on the suction
line to the pump.
WARNING
To Reduce the Risk of Fire, install pool equipment in
an area where leaves or other debris will not collect
on or around the equipment. Keep surrounding area
clear of all debris such as paper, leaves, pine-needles
and other combustible materials.
WARNING
Some Safety Vacuum Release System (SVRS) devices
are not compatible with the installation of check valves.
If the pool has an SVRS device, be sure to confirm
that it will continue to safely operate when any check
valves are installed.
NOTE To achieve better self-priming, install the
pump as close as possible to the water level
of the pool.
2. If the pump is located below water level, isolation
valves must be installed on both the suction and
return lines to prevent back flow of pool water during
any routine or required servicing.
3. The pump and other circulation equipment must
be located more than five (5) feet from the water.
Choose a location that will minimize turns in the
piping.
NOTE In Canada, the pump must be located a minimum
of three (3) meters (approximately 10 feet) from
the water (CSA C22.1).
Page 7
Jandy
® Pro Series ePump™ Series Pump | Installation and Operation Manual ENGLISH

5.2 Winterizing the Pump
CAUTION
The pump be protected when freezing must
temperatures are expected. Allowing the pump
to freeze will cause severe damage and void the
warranty.
CAUTION
Do not use antifreeze solutions in the pool,
spa, or hot tub systems! Antifreeze is highly toxic
and may damage the circulation system. The only
exception to this is Propylene Glycol. For more
information, see your local pool/spa supply store or
contact a qualified swimming pool service company.
1. Drain water from the pump, system equipment, all
and piping.
2. Remove the two (2) drain plugs. Store the drain
plugs in a safe location and reinstall them when
the cold weather season is over. Do not lose
the o-rings.
3. Keep the motor covered and dry. Do not cover
the pump with plastic, because this will create
condensation that will damage the pump.
NOTE Zodiac Pool Systems, Inc. recommends having
a qualified service technician or electrician
properly disconnect the electrical wiring at
the switch or junction box. Once the power is
removed, loosen the two (2) unions and store
the pump indoors. For safety, and to prevent
entry of contaminants, reinstall all conduit and
terminal box covers.
4. When the system is reopened for operation,
have a qualified technician or electrician make
sure all piping, valves, wiring and equipment
are in accordance with the manufacturer’s
recommendations. Pay close attention to the filter
and electrical connections.
5. The pump must be primed prior to starting. Refer
to .Section 4.1, Start-up
Page 16
Jandy® Pro Series ePump™ Series Pump | Installation and Operation Manual
ENGLISH
Specyfikacje produktu
Marka: | JANDY |
Kategoria: | Przepych |
Model: | VSSHP220AUT |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z JANDY VSSHP220AUT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Przepych JANDY

22 Września 2024

22 Września 2024

22 Września 2024

22 Września 2024

21 Września 2024

20 Września 2024

20 Września 2024

20 Września 2024

20 Września 2024

19 Września 2024
Instrukcje Przepych
- Przepych Worx
- Przepych Milwaukee
- Przepych SilverCrest
- Przepych Simpson
- Przepych Ultimate Speed
- Przepych Parkside
- Przepych Ferroli
- Przepych Toolcraft
- Przepych Kärcher
- Przepych Bestway
- Przepych Scheppach
- Przepych Ribimex
- Przepych Quigg
- Przepych Hazet
- Przepych Siemens
- Przepych Gardena
- Przepych Einhell
- Przepych Hyundai
- Przepych Husqvarna
- Przepych Makita
- Przepych Ozito
- Przepych Testo
- Przepych Fuxtec
- Przepych Fiap
- Przepych RYOBI
- Przepych Polaris
- Przepych Biltema
- Przepych Hozelock
- Przepych Crivit
- Przepych Osram
- Przepych Trotec
- Przepych AL-KO
- Przepych Danfoss
- Przepych Güde
- Przepych Panduit
- Przepych Vaillant
- Przepych Zipper
- Przepych Grundfos
- Przepych Fluke
- Przepych Bartscher
- Przepych Lavorwash
- Przepych Fluval
- Przepych Neptun
- Przepych Westfalia
- Przepych Hayward
- Przepych Ergotools Pattfield
- Przepych Lezyne
- Przepych Eheim
- Przepych Zehnder Pumpen
- Przepych Oase
- Przepych Michelin
- Przepych Aerotec
- Przepych Blumfeldt
- Przepych Fieldmann
- Przepych Technaxx
- Przepych Gardenline
- Przepych PowerPlus
- Przepych Alpha Tools
- Przepych Vonroc
- Przepych Powerfix
- Przepych OKAY
- Przepych Metabo
- Przepych Ubbink
- Przepych AstralPool
- Przepych Gre
- Przepych Eurom
- Przepych Enermax
- Przepych Blackburn
- Przepych Nefit
- Przepych Vetus
- Przepych Sicce
- Przepych Outwell
- Przepych Sun Joe
- Przepych Tacklife
- Przepych SKS
- Przepych Nibe
- Przepych Melinera
- Przepych Sanibroyeur
- Przepych Zodiac
- Przepych Topeak
- Przepych Bulex
- Przepych For_Q
- Przepych Abac
- Przepych Waldbeck
- Przepych Cannondale
- Przepych Coleman
- Przepych Maruyama
- Przepych Jabsco
- Przepych Eufab
- Przepych Pontec
- Przepych Batavia
- Przepych ESPA
- Przepych T.I.P.
- Przepych Pedrollo
- Przepych Velda
- Przepych Vivaria
- Przepych Plantiflor
- Przepych Verto
- Przepych Little Giant
- Przepych Wetelux
- Przepych Germania
- Przepych Anova
- Przepych DAB
- Przepych Esotec
- Przepych Wayne
- Przepych Rule
- Przepych Elpumps
- Przepych Hollex
- Przepych B-Air
- Przepych Baracuda
- Przepych Lifan
- Przepych Liberty Pumps
- Przepych BluGarda
- Przepych Madimack
- Przepych Sauermann
- Przepych Eco-Flo
- Przepych Nowax
- Przepych Zoeller
- Przepych Superior Pump
- Przepych SHURflo
- Przepych EvoHeat
- Przepych MSW
- Przepych Barwig
- Przepych Ebara
- Przepych Perlick
- Przepych Basement Watchdog
- Przepych Zéfal
- Przepych Comet
- Przepych Heissner
- Przepych OSIP
- Przepych Franklin Electric
Najnowsze instrukcje dla Przepych

11 Stycznia 2025

11 Stycznia 2025

11 Stycznia 2025

11 Stycznia 2025

4 Stycznia 2025

4 Stycznia 2025

4 Stycznia 2025

2 Stycznia 2025

1 Stycznia 2025

1 Stycznia 2025