JA-68 universal output module 2 / 2 MGK23701
The JA-68 universal output module
The JA-68 is a universal output module designed for use within Jablotron
systems of the JA-80 OASiS, JA-63 Profi and JA-65 Maestro series. The
module provides eight factory pre-programmed semiconductor outputs and a
switch-over relay output. The relay can be configured using 10 DIP switches
which allows for multiple function assignment. There is no limit in the number
of JA-68 modules used in the system. There is no limit to the number of
JA-68 modules used in the system and the JA-68 module can be combined
with GSM, LAN or PSTN (landline) communicators.
The module is designed for being placed into the control panel
housing.
NC
C
NO
Figure 1
Semiconductor outputs
All semiconductor outputs are switchable to a common terminal labelled
“C”. The switching ON/OFF logic can be reversed by setting a jumper JP1 to
the NC position (the factory default is NO).
Description of the terminals:
Terminal Function
+U Positive power supply from the digital bus (limited to 200 mA)
GND Negative pole of the power supply
C Common terminal (for all semiconductor outputs)
ARM Anything-set status (A or AB or ABC)
ALM Intruder alarm
FIR Fire alarm
TMP Tamper alarm
PNC Panic alarm
FLT Fault indication (general faults, radio communication faults,
back-up battery supply faults)
AC Mains (230V) supply fault
LB Low battery indication (applies to wireless devices such as
detectors, keypads, sirens or thermostats)
Relay configuration
The relay is configurable via a set of 10 DIP switches (see Table 2). The
relay works with OR logic: it is switched ON if there is at least one preset
function activated.
Example: Setting switches 2,3,4 and 5 to ON causes the relay to
indicate intrusion, fire, tamper or panic alarms i.e. the relay switches ON if
any of the four mentioned alarm states are activated.
DIP switches assignments:
Number Label Function
1 ARM Anything set
2 ALM Intrusion alarm
3 FIR Fire alarm
4 TMP Tamper alarm
5 PNC Panic alarm
6 FLT System fault
7 AC Power supply fault
8 LB Low battery
9 PGX Control panel PGX output
10 PGY Control panel PGY output
Description of relay terminals:
Label Description
NC Normally Closed relay contact
C Common relay contact
NO Normally Open relay contact
Note: There is a minimum output activation time of 10 seconds for each
of the 8 + 1 outputs.
Specification
Power supply 12V (taken from the control panel)
Stand-by consumption 4mA
Maximum consumption (all outputs activated) 50mA
Outputs 8 semiconductor switches
+ 1 switch-over relay
Maximum current for single output activation 200mA
Maximum current for C, NC or NO activation 1A / 60V
Minimum output activation time 10 sec.
Digital bus connection 2x RJ-44 data connectors
Environment indoor general
Operational temperature range –10 to +40 °C
Complies with EN 50130-4,EN 55022
JABLOTRON ALARMS a.s. hereby declares that the JA-68
is in compliance with the essential requirements and other
relevant provisions of Directive 2004/108/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the manufacturer after use.


Specyfikacje produktu

Marka: Jablotron
Kategoria: Bezpieczeństwo
Model: JA-68

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Jablotron JA-68, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Bezpieczeństwo Jablotron

Instrukcje Bezpieczeństwo

Najnowsze instrukcje dla Bezpieczeństwo