Instrukcja obsługi ICOM RMK-3

ICOM radio RMK-3

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla ICOM RMK-3 (2 stron) w kategorii radio. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
INSTRUCTIONS
SEPARATION KIT
RMK-3
Thank you for purchasing the RMK-3
SEPARATION KIT
.
The RMK-3 allows you to install the mobile trans-
ceiver front panel separately from the main body for
added installation convenience and operation. Use
either the optional OPC-607, OPC-608 or OPC-609
SEPARATION CABLE
with the RMK-3.
In this instruction, the illustration is described using the IC-
F5060 series transceiver.
Separation
The optional OPC-607 , OPC-608 (3 m; 9.84 ft) (8 m; 26.3 ft) or
OPC-609* (1.9 m; 6.3 ft)
SEPARATION CABLE
is required for in-
stalling the transceiver front panel and main body separately.
*For Europe version, only the OPC-609 is available.
q Turn the transceiver’s power OFF, then disconnect the DC
power cable.
w Unscrew the 4 bottom screws, then remove the bottom
cover from the transceiver in the direction of the arrow.
e Remove the front panel from the main body using a stan-
dard screw driver as shown below.
r Disconnect the flat cable from the front panel.
t Unscrew the 4 rear plate screws, then remove the rear
plates from both the front panel and main body attach-
ments.
Continue to the back page.
Rear plate
*This illustration
shows the descrip-
tion for the front
panel attachment.
Unscrew the cir-
cuit board screw.
Front panel
Flat cable Main body
Front panel
Flat cable
Main body
Front panel
Standard
screw driver
qw
e
Bottom cover
CAUTION! To avoid damage to the transceiver, turn the
power OFF before separating the front panel from the
main body.
Supplied accessories
Main body attachment
Front panel attachment Flat cable
Mounting bracket Flat washers
(M5)
Spring washers
(M5)
Mounting screws
(M5 12)×
Self-tapping screws
(M5 16)×
Bracket screwsNuts (M5)
Icom, Icom Inc. and the logo are registered trademarks of Icom Incor-
porated (Japan) in the United States, the United Kingdom, Germany, France,
Spain, Russia and/or other countries.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan A-6573H-1EX Printed in Japan
© 2007 Icom Inc.
Mounting
2 types of mounting styles are available one is overhead
mounting, and other one is on-board mounting.
Mount the front panel and the attachment securely with the
4 supplied screws to a thick surface which can support more
than 1.5 kg. (Overhead mounting)
On-board mounting
Overhead mounting
When using
self-tapping screws
Flat washer
Spring washer
Bracket
screw
Bracket screw
Attachment
For the front panel attachment:
q Connect the optional OPC-607, OPC-608 or OPC-609 to
the front panel attachment as shown below.
After the cable connection, replace the removed rear plate
and the 4 screws.
The optional cable can be inserted into either the left or right
grooves as desired on the back of the attachment.
w Connect the at cable (q) as shown below, and then at-
tach the front panel and the attachment (w).
• fl Ensure the at cable is inserted correctly, and not upside down.
For the main body attachment:
e Connect the optional OPC-607, OPC-608 or OPC-609 to
the main body attachment as shown below.
After the cable connection, replace the removed rear
plate.
The optional cable can be inserted into either the left or right
grooves as desired on the back of the attachment.
r Connect the supplied at cable* and ground cable (coming
from the RMK-3) as shown below.
*Ensure the at cable and attachment are inserted/attached cor-
rectly, and not upside down.
t Replace the removed bottom cover and 4 screws, then re-
connect the DC power cable.
Main body attachment
to transceiver s
main body
Main body
Main body attachment*
Flat cable*
Flat cable*
from the RMK-3
Use the attached screw
OPC-607/
OPC-608/
OPC-609
Rear plate
Main body attachment
Cable groove
Use the screw re-
moved from the cir-
cuit board in step t
on the front page, to
connect the cable lug.
Front panel
Front panel attachment
Flat cable
q
w
Attach the front
panel and attach-
ment securely.
OPC-607/
OPC-608/
OPC-609 Rear plate
Front panel attachment
Use the screw re-
moved from the cir-
cuit board in step t
on the front page, to
connect the cable lug.
Cable groove
Printed on recycled paper with soy ink.


Specyfikacje produktu

Marka: ICOM
Kategoria: radio
Model: RMK-3

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z ICOM RMK-3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje radio ICOM

ICOM

ICOM IC-F6021/51 Instrukcja

12 Września 2024
ICOM

ICOM IC-M25 Instrukcja

11 Września 2024
ICOM

ICOM IC-2300H Instrukcja

4 Września 2024
ICOM

ICOM AH-4 Instrukcja

20 Sierpnia 2024
ICOM

ICOM RMK-3 Instrukcja

6 Lipca 2024

Instrukcje radio

Najnowsze instrukcje dla radio

Ruarkaudio

Ruarkaudio Rseven Instrukcja

15 Października 2024
Ruarkaudio

Ruarkaudio MR1 Instrukcja

15 Października 2024
Denver

Denver TWE-55B Instrukcja

15 Października 2024
Audiosonic

Audiosonic CL-1486 Instrukcja

14 Października 2024
Sangean

Sangean DPR-39 Instrukcja

13 Października 2024
Roberts

Roberts Stream 93i Instrukcja

13 Października 2024
Sangean

Sangean RCR-9 Instrukcja

13 Października 2024
Uniden

Uniden UH45CP Instrukcja

12 Października 2024
Muse

Muse M-178 P Instrukcja

10 Października 2024
Sencor

Sencor SIR 5000WDB Instrukcja

10 Października 2024