Instrukcja obsługi Greisinger GMH 3750


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Greisinger GMH 3750 (16 stron) w kategorii termometr. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
H49.0.02.6B-06
GREISINGER electronic GmbH
D - 93128 Regenstauf, Hans-Sachs-Straße 26
Phone: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, eMail: info@greisinger.de
Operating Manual Precision Thermometer
as of Version 1.8
Pt100 4-Wire
GMH 3750
H49.0.02.6C-06 Operating Manual GMH 3750 Page 2 of 16
_____________________________________________________ _______________________________________________________________________________
Contents
1 INTENDED USE .........................................................................................................................................3
2 GENERAL ADVICE...................................................................................................................................3
3 SAFETY INSTRUCTIONS ........................................................................................................................3
4 OPERATING AND MAINTENANCE......................................................................................................4
5 CONNECTIONS..........................................................................................................................................4
6 DISPLAY- AND BUTTON ELEMENTS..................................................................................................5
7 START OF OPERATION ..........................................................................................................................5
8 DEVICE CONFIGURATION ....................................................................................................................6
9 SPECIAL FUNCTIONS..............................................................................................................................8
9.1 DISPLAY RESOLUTION..............................................................................................................................8
9.2 USER S CENSOR URVE ('LIN USER')..........................................................................................................8
9.3 ZERO DISPLACEMENT ('OFFSET') ..............................................................................................................8
9.4 SCALE CORRECTION ('SCALE')..................................................................................................................8
9.5 AVERAGE FILTER (T.A G“)...................................................................................................................9U
9.6 OUTPUT („OUT“).....................................................................................................................................9
9.7 ALARM („AL.“)......................................................................................................................................10
9.8 REAL T CIME LOCK („CLOC“) ...............................................................................................................10
10 PROBE CONNECTION........................................................................................................................11
11 CALIBRATION SERVICES ................................................................................................................11
12 OPERATION OF LOGGER.................................................................................................................12
12.1 STORING SINGLE MEASUREMENTS („FUNC-STOR“) ...............................................................................12
12.2 AUTOMATIC RECORDING WITH SELECTABLE LOGGER CYCLE TIME „FUNC CYCL“..............................13
13 SOME BASICS OF PRECISION TEMPERATURE MEASURING ...............................................14
14 FAULT AND SYSTEM MESSAGES...................................................................................................15
15 DISPOSAL NOTES ...............................................................................................................................15
16 SPECIFICATION ..................................................................................................................................16
© Copyright 2008 GREISINGER electronic GmbH. All Rights Reserved.
No part of this documentation may without previous written permission of the company
GREISINGER electronic GmbH stored in some form, reproduced, processed,
duplicated or spread become.
H49.0.02.6C-06 Operating Manual GMH 3750 Page 3 of 16
_____________________________________________________ _______________________________________________________________________________
1 Intended Use
The GMH 3750 is a precision thermometer for the measurement of the temperature with
exchangeable 4-wire Pt100 temperature sensors. With high resolution and precision temperature
values can be measured from -200 to 850 °C.
The device is to be protected against wetness and soiling and has to be stored and operated only
within the permissible environmental conditions and connection data (see “Specification”).
2 General Advice
Read through this document attentively and make yourself familiar to the operation of the device
before you use it. Keep this document in a ready-to-hand way in order to be able to look up in the
case of doubt.
3 Safety Instructions
This device has been designed and tested in accordance to the safety regulations for electronic
devices. However, its trouble-free operation and reliability cannot be guaranteed unless the
standard safety measures and special safety advises given in this manual will be adhered to when
using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected
to any other climatic conditions than those stated under “Specification”.
Transporting the device from a cold to a warm environment condensation may result in a failure
of the function. In such a case make sure
the device temperature has adjusted to the ambient
temperature before trying a new start-up.
2. The circuitry has to be designed most carefully, especially if the device should be connected to
other devices. Internal connection in third party devices (e.g. connection GND and earth) may
result in not-permissible voltages impairing or destroying the device or another device
connected.
3. Warning: Operating the device with a defective mains power supply (e.g. short circuit from
mains voltage to output voltage) may result in hazardous voltages at the device (e.g. at sensor
socket)
4. Whenever there may be a risk whatsoever involved in running it, the device has to be
switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may
be a risk if:
there is visible damage to the device
the device is not working as specified
the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.
5.
Warning: Do not use these product as safety or emergency stop device, or in any other
application where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material
damage.


Specyfikacje produktu

Marka: Greisinger
Kategoria: termometr
Model: GMH 3750

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Greisinger GMH 3750, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termometr Greisinger

Instrukcje termometr

Najnowsze instrukcje dla termometr

Auriol

Auriol H14269 Instrukcja

15 Października 2024
Medel

Medel ECOtemp Instrukcja

9 Października 2024
Medel

Medel No Contact Plus Instrukcja

9 Października 2024
Medel

Medel Flexo Instrukcja

9 Października 2024
Owon

Owon TI300 Instrukcja

8 Października 2024
Innoliving

Innoliving INMD-DMT-437 Instrukcja

8 Października 2024