Instrukcja obsługi Gossen Metrawatt METRACLIP 88
Gossen Metrawatt
multimetr
METRACLIP 88
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Gossen Metrawatt METRACLIP 88 (52 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/52
METRA CLIP 88
CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 88 English
CONTENTS
1 PRESENTATION............................................................................................................ 8
1.1 THE SWITCH ....................................................................................................................... 9
1.2 THE KEYS OF THE KEYPAD ........................................................................................ 10
1.3 THE DISPLAY UNIT ........................................................................................................ 11
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 12
1.4 THE TERMINALS ............................................................................................................. 13
2 THE KEYS ..................................................................................................................... 13
2.1 KEY ...................................................................................................................................... 13
2.2 KEY (SECOND FUNCTION) ................................................................................................... 14
2.3 KEY ...................................................................................................................................... 15
2.4 KEY ...................................................................................................................................... 15
2.4.1 In the normal mode ......................................................................................... 15
2.4.2 The MAX/MIN/PEAK mode + activation of the HOLD mode....................... 16
2.4.3 Access to the True- INRUSH mode ( set to ) ...................................16
2.5 KEY ...................................................................................................................................... 17
2.5.1 The Hz function in the normal model ............................................................. 17
2.5.2 The Hz function + activation of the HOLD mode .......................................... 18
2.6 KEY ...................................................................................................................................... 18
3 USE .................................................................................................................................. 19
3.1 COMMISSIONING ........................................................................................................... 19
3.2 STARTING UP THE MULTIMETER CLAMP ............................................................. 20
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 20
3.4 CONFIGURATION ........................................................................................................... 20
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 21
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 21
3.4.3 Programming of the current threshold for the True INRUSH measurement 21
3.4.4 Default configuration ...................................................................................... 22
3.5 VOLTAGE MEASUREMENT (V) .................................................................................. 22
3.6 CONTINUITY TEST ................................................................................................... 23
3.6.1 Automatic compensation of the resistance of the leads ................................. 24
3.7 RESISTANCE MEASUREMENT Ω .............................................................................. 24
3.8 DIODE TEST ............................................................................................................... 25
3.9 CURRENT MEASUREMENT (A) .................................................................................. 25
3.9.1 AC measurement ............................................................................................. 25
3.9.2 DC or AC+DC measurement.......................................................................... 26
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
27
2
English Clamp Multimeter METRACLIP 88
3.11 POWER MEASUREMENTS W, VA, VAR AND PF ..................................................... 27
3.11.1 Measurement of singl phase powere- .............................................................. 28
3.11.2 Balanced three-phase power measurement.................................................... 28
3.12 “DIRECTION OF ROTATION OF OR OF THE PHASES” “ORDER THE PHASES”
MODE .................................................................................................................................... 29
3.13 FREQUENCY MEASUREMENT (HZ) .......................................................................... 30
3.13.1 Frequency measurement in voltage ................................................................ 30
3.13.2 Frequency measurement in current ................................................................ 31
3.13.3 Measurement of frequency in power .............................................................. 31
3.14 MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE
FREQUENCY OF THE FUNDAMENTAL (NETWORK) ....................................................... 31
3.14.1 Measurement of the THD and of the frequency of the fundamental in voltage
32
3.14.2 Measurement of the THD and of the frequency of the fundamental in current
32
4 CHARACTERISTICS .................................................................................................. 34
4.1 REFERENCE CONDITIONS ........................................................................................... 34
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 34
4.2.1 DC voltage measurement ................................................................................ 34
4.2.2 AC voltage measurement ................................................................................ 35
4.2.3 AC+DC voltage measurement ........................................................................ 36
4.2.4 DC current measurement ................................................................................ 37
4.2.5 AC current measurement ................................................................................ 37
4.2.6 AC+DC intensity measurement ...................................................................... 38
4.2.7 True-Inrush measurement ............................................................................... 39
4.2.8 Continuity measurement ................................................................................. 39
4.2.9 Resistance measurement ................................................................................. 39
4.2.10 Diode test ......................................................................................................... 40
4.2.11 Active DC power measurements ................................ ..................................... 40
4.2.12 Active AC power measurements ..................................................................... 41
4.2.13 Active AC+DC power measurements ............................................................. 42
4.2.14 Measurement of apparent AC power .............................................................. 43
4.2.15 Measurement of apparent AC+DC power ..................................................... 43
4.2.16 Measurement of reactive AC power ............................................................... 44
4.2.17 Measurement of reactive AC+DC power ....................................................... 45
4.2.18 Calculation of the power factor ...................................................................... 45
4.2.19 Frequency measurements................................................................................ 46
4.2.20 Characteristics in THDr ................................................................................. 47
4.2.21 Characteristics in THDf .................................................................................. 47
4.2.22 Indication of order of the phases .................................................................... 47
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 48
4.4 CHARACTERISTICS OF CONSTRUCTION............................................................... 48
4.5 ............................................................................................................... POWER SUPPLY 48
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 48
3
Specyfikacje produktu
Marka: | Gossen Metrawatt |
Kategoria: | multimetr |
Model: | METRACLIP 88 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Gossen Metrawatt METRACLIP 88, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Gossen Metrawatt
3 Października 2024
2 Października 2024
2 Października 2024
2 Października 2024
2 Października 2024
2 Października 2024
2 Października 2024
23 Września 2024
22 Września 2024
22 Września 2024
Instrukcje multimetr
- multimetr PeakTech
- multimetr Joy-It
- multimetr Voltcraft
- multimetr Milwaukee
- multimetr GW Instek
- multimetr Stanley
- multimetr Silverline
- multimetr Testo
- multimetr Aim TTi
- multimetr TFA
- multimetr Chauvin Arnoux
- multimetr Gembird
- multimetr Uni-T
- multimetr Owon
- multimetr Digitus
- multimetr Vimar
- multimetr Emos
- multimetr Sonel
- multimetr Trotec
- multimetr Velleman
- multimetr Pyle
- multimetr Fluke
- multimetr Megger
- multimetr Weidmüller
- multimetr BENNING
- multimetr Brandson
- multimetr Metrix
- multimetr Rigol
- multimetr Ferm
- multimetr Extech
- multimetr Testboy
- multimetr Kyoritsu
- multimetr Klein Tools
- multimetr Powerfix
- multimetr Workzone
- multimetr Alecto
- multimetr Monacor
- multimetr Etekcity
- multimetr HT Instruments
- multimetr Qian
- multimetr Beha-Amprobe
- multimetr Laserliner
- multimetr Ideal
- multimetr Profile
- multimetr Appa
- multimetr Amprobe
- multimetr Tacklife
- multimetr Somogyi
- multimetr Steren
- multimetr Flir
- multimetr Maxwell
- multimetr Topcraft
- multimetr Altai
- multimetr Plieger
- multimetr Cablexpert
- multimetr Greenlee
- multimetr Högert
- multimetr Wago
- multimetr REV
- multimetr Bruder Mannesmann
- multimetr Keithley
- multimetr Bearware
- multimetr Metrel
- multimetr Multimetrix
- multimetr Digi-tool
- multimetr Skandia
- multimetr Elma
- multimetr Kewtech
- multimetr Strex
- multimetr Mastech
- multimetr MBS
- multimetr MGL Avionics
- multimetr PCE Instruments
- multimetr Micronta
- multimetr CEM
- multimetr Horex
- multimetr Cosinus
- multimetr Kurth Electronic
- multimetr Weltron
- multimetr Sanwa
- multimetr Rohde & Schwarz
- multimetr EEVBlog
- multimetr Kingcraft
- multimetr Caltek
- multimetr Elworks
- multimetr Noyafa
Najnowsze instrukcje dla multimetr
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
7 Października 2024
6 Października 2024
5 Października 2024