The Quick Reference Card provides a quick overview of your spa’s
main functions and the operations accessible from your keypad.
Key 1
Press Key 1 to turn Pump 1 on at low speed. Press a second time to turn pump to
high speed (with a dual-speed pump). A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes*, unless pump has
been manually deactivated first.
The “Pump 1” indicator lights up when Pump 1 is on.
With dual-speed pump, indicator will flash when Pump 1 is on at low speed.
Spa functions
K-19
Key 2 (2 Pump System)
(If equipped with Pump 2)
Press Key 2 to turn Pump 2 on at low speed. Press a second time to turn pump to
high speed. A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes*, unless it has been
manually deactivated first.
The “Pump 2” indicator lights up when Pump 2 is on.
The indicator will flash when Pump 2 is on at low speed.
Key 2 (2-Pump/Blower System)
(If equipped with blower)
Press Key 2 to turn Pump 2 on at high speed. Pressing a second time turns blower on.
A third press turns Pump 2 off but leaves blower on. A final press turns blower off.
A built-in timer automatically turns Pump 2/blower off after 20 minutes*, unless
Pump 2/blower has been manually deactivated first.
The “Pump 2” indicator
lights up when Pump 2 is on. The “Blower” indicator
lights up when blower is on.
Single pump system
Two pump system
* Default time
Programming the purge / filter cycles
Light key
Press the Light key to turn light on. Press a second time to turn light off.
A built-in timer automatically turns light off after 2 hours, unless it has been
manually deactivated first.
The “Light” indicator lights up
when light is on.
Up/Down keys
Use Up or Down key to set desired water temperature. The temperature
setting will be displayed for 5 seconds to confirm your new selection.
The "Set Point" icon indicates that the display shows the
desired temperature, NOT the current water temperature!
Setting filter cycle duration
Press and hold the Light key until the display shows dxx, with "xx" representing
the duration in hours. (Default: 2 hours).
Use Up or Down key to change setting.
0 = no filtration 24 = continuous filtration
Note: it's not recommended to set this to "0".
Programming filter cycles
Depending on system configuration the system performs either purge cycles or filter cycles.
To program the filter cycles, you must enter these parameters: duration and frequency.
During a filter cycle, pumps & blower run at high speed for one minute to purge the
plumbing. Pump 1 or CP then runs at low speed for the remainder of the cycle.
Off Mode
(If present)
This mode allows you to stop all outputs for 30 minutes to perform a quick spa
maintenance.
Press and hold Key 1 for 5 secs to activate the Off mode. Quickly press Key 1 to
reactivate the system before the expiration of the 30-minute delay.
While the Off mode is engaged, the display will toggle between OFF and the
water temperature.
OFF
Smart Winter Mode
Our Smart Winter Mode protects your
system from the cold by turning pumps on
several times a day to prevent water from
freezing in pipes.
The “Smart Winter Mode” indicator
lights up when the Smart Winter Mode
is on.
Filter cycle frequency
Press the Light key again. The display will show Fx, with "x" representing the
number of filter cycles per day (up to 4). (Default: twice a day).
Use Up or Down key to change setting.
When the desired setting is displayed, press the Light key
to confirm. A filter cycle will start immediately.
The “Filter” indicator lights up
when a filter cycle is on.
Purge cycle frequency
Press and hold the Light key until the display shows Fx, with "x" representing the
number of purge cycles per day (up to 4).
Use Up or Down key to change setting.
When the desired setting is displayed, press the Light
key to confirm. A purge cycle will start immediately.
The “Filter” indicator lights up
when a purge cycle is on.
Programming purge cycles
To program the purge cycles, you must select the frequency. During a purge cycle, all pumps
and the blower run for one minute. To set purge cycles:
Setting the temperature display units
Quickly press the Light key again. The display will show either °F or °C.
Use Up or Down key to change units.
Press the Light key a last time to go back to normal mode.
°F = Fahrenheit °C = Celsius
Water temperature regulation
In a regulation cycle, the system first gener-
ates water flow through the heater housing
and the plumbing, in order to ensure accu-
rate water temperature readings as well as
avoiding heater activation in dry conditions.
After verifying pump activation and taking a
water temperature reading if required, the
system automatically turns the heater on to
reach and maintain water temperature at
Set Point.
The “Heaterindicator lights up when
the heater is on. It flashes when there
is a request for more heat but the
heater has not yet started.
Cooldown
While performing this task, the heater is not
allowed to turn on and its icon flashes.