Instrukcja obsล‚ugi Extech VFM200


Przeczytaj poniลผej ๐Ÿ“– instrukcjฤ™ obsล‚ugi w jฤ™zyku polskim dla Extech VFM200 (5 stron) w kategorii Narzฤ™dzie wielofunkcyjne. Ta instrukcja byล‚a pomocna dla 7 osรณb i zostaล‚a oceniona przez 2 uลผytkownikรณw na ล›rednio 4.5 gwiazdek

Strona 1/5
User๎˜ƒManual๎˜ƒ
๎˜ƒ
๎˜ƒ
Formaldehyde๎˜ƒ(HCHO๎˜ƒor๎˜ƒCH20) and๎˜ƒ ๎˜ƒTotal๎˜ƒ
Volatile๎˜ƒOrganic๎˜ƒCompounds๎˜ƒ(TVOC)๎˜ƒTester๎˜ƒ
๎˜ƒ
Model๎˜ƒVFM200๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
Additional๎˜ƒUser๎˜ƒManual๎˜ƒTranslations๎˜ƒavailable๎˜ƒ ๎˜ƒat www.extech.com๎˜ƒ
๎˜ƒ
2๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒVFM200โ€enโ€GB_V1.2๎˜ƒ๎˜ƒ๎˜ƒ12/16๎˜ƒ
1
6
5
7
2
3
4
8
Introduction๎˜ƒ
๎˜ƒ
Thank๎˜ƒ ๎˜ƒyou for The๎˜ƒselecting๎˜ƒthe Extech๎˜ƒ ๎˜ƒInstruments๎˜ƒModel๎˜ƒVFM200.๎˜ƒ ๎˜ƒVFM200๎˜ƒmeasures๎˜ƒHCHO๎˜ƒ
(formaldehyde)๎˜ƒand๎˜ƒTVOC๎˜ƒ(Total๎˜ƒVolatile๎˜ƒOrganic๎˜ƒCompounds).๎˜ƒ
Potential๎˜ƒsources paints,๎˜ƒfor๎˜ƒTVOCs๎˜ƒinclude๎˜ƒ ๎˜ƒfinishes,๎˜ƒadhesives,๎˜ƒcigarette๎˜ƒsmoke,๎˜ƒpesticides,๎˜ƒ
personal๎˜ƒcare wall๎˜ƒproducts,๎˜ƒcar๎˜ƒexhaust, furnishings,๎˜ƒnew๎˜ƒ ๎˜ƒ ๎˜ƒcoverings,๎˜ƒhousehold๎˜ƒcleansers,๎˜ƒand๎˜ƒ
cooking๎˜ƒfuels. Acetone, Formaldehyde,๎˜ƒChemicals include:๎˜ƒ ๎˜ƒ ๎˜ƒEthylene๎˜ƒGlycol,๎˜ƒ ๎˜ƒ ๎˜ƒXylene, 1,3โ€butadiene,๎˜ƒ
Tetrachloroethene,๎˜ƒHydrogen๎˜ƒSulfide,๎˜ƒAmmonia,๎˜ƒToluene,๎˜ƒBenzene,๎˜ƒMethylene๎˜ƒChloride,๎˜ƒ
Perchloroethylene,๎˜ƒand๎˜ƒMTBE.๎˜ƒ
This calibrated๎˜ƒdevice๎˜ƒis๎˜ƒshipped tested๎˜ƒfully๎˜ƒ ๎˜ƒand๎˜ƒ ๎˜ƒand,๎˜ƒwith๎˜ƒproper๎˜ƒuse,๎˜ƒwill๎˜ƒprovide๎˜ƒyears๎˜ƒof๎˜ƒreliable๎˜ƒ
service. for๎˜ƒPlease๎˜ƒvisit๎˜ƒour๎˜ƒ ๎˜ƒ ๎˜ƒwebsite (www.extech.com) to๎˜ƒcheck๎˜ƒ ๎˜ƒthe๎˜ƒlatest๎˜ƒversion๎˜ƒof๎˜ƒthis๎˜ƒUser๎˜ƒ
Guide,๎˜ƒProduct๎˜ƒUpdates,๎˜ƒand๎˜ƒCustomer๎˜ƒ ๎˜ƒSupport.
Features๎˜ƒ
๏‚ท Fuel๎˜ƒ ๎˜ƒCell Formaldehyde๎˜ƒSensor๎˜ƒTechnology๎˜ƒ
๏‚ท High๎˜ƒ ๎˜ƒaccuracy measurements๎˜ƒ
๏‚ท Backlit๎˜ƒ ๎˜ƒLCD display๎˜ƒ
๏‚ท Realโ€ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒtime display of HCHO (formaldehyde)๎˜ƒconcentration๎˜ƒin๎˜ƒair๎˜ƒ
๏‚ท Realโ€๎˜ƒtime๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒdisplay of TVOC (Total๎˜ƒVolatile๎˜ƒOrganic๎˜ƒCompounds)๎˜ƒconcentration๎˜ƒin๎˜ƒair๎˜ƒ
๏‚ท Two๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒunit selections (PPM, mg/mยณ)๎˜ƒ
๏‚ท Audioโ€ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒvisual High and Low Alarms for HCHO๎˜ƒ
๏‚ท Auto๎˜ƒpower๎˜ƒoff๎˜ƒ
๎˜ƒ
Description๎˜ƒ
๎˜ƒ
METER๎˜ƒDESCRIPTION๎˜ƒ
1. HCHO๎˜ƒsensor๎˜ƒ(front)๎˜ƒ
2. AC๎˜ƒAdaptor๎˜ƒjack๎˜ƒ(under๎˜ƒflap)๎˜ƒ
3. Down๎˜ƒarrow๎˜ƒand๎˜ƒAlarm๎˜ƒSetup๎˜ƒbutton๎˜ƒ
4. Battery ๎˜ƒcompartment๎˜ƒ(rear)๎˜ƒ
5. ONโ€OFF๎˜ƒbutton๎˜ƒ(also๎˜ƒused๎˜ƒin๎˜ƒAlarm๎˜ƒSetup)๎˜ƒ
6. Up๎˜ƒarrow๎˜ƒand๎˜ƒUNIT๎˜ƒselection๎˜ƒbutton๎˜ƒ
7. Backlit๎˜ƒDisplay๎˜ƒ
8. TVOC๎˜ƒsensor๎˜ƒ(rear)๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
3๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒVFM200โ€enโ€GB_V1.2๎˜ƒ๎˜ƒ๎˜ƒ12/16๎˜ƒ
mg/m
mg/m
3
3
1
2
3
4
5
6
7
LCD๎˜ƒDISPLAY๎˜ƒ
1. HCHO๎˜ƒreading๎˜ƒ
2. TVOC๎˜ƒreading๎˜ƒ
3. Selectable๎˜ƒunits of๎˜ƒ ๎˜ƒmeasure๎˜ƒ
4. Alarm๎˜ƒBeeper๎˜ƒsymbol๎˜ƒ
5. Auto๎˜ƒPower๎˜ƒOFF๎˜ƒreminder๎˜ƒ
6. Rechargeable๎˜ƒBattery๎˜ƒstatus๎˜ƒ
7. High๎˜ƒand๎˜ƒLow Alarm๎˜ƒ ๎˜ƒsymbols๎˜ƒ
Operation๎˜ƒ
POWER๎˜ƒTHE๎˜ƒMETER๎˜ƒ
Press๎˜ƒthe๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒbutton to turn on the meter. The battery symbol informs the user as to the battery
strength.๎˜ƒConnect๎˜ƒthe recharge the the๎˜ƒbattery๎˜ƒcharger๎˜ƒto๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒbattery. Long๎˜ƒpress๎˜ƒ ๎˜ƒ ๎˜ƒbutton๎˜ƒto๎˜ƒ
power๎˜ƒoff.๎˜ƒ๎˜ƒ๎˜ƒThe๎˜ƒLCD๎˜ƒwill๎˜ƒcount๎˜ƒdown:๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ3, 2, 1, then OFF before switching off.
AUTO๎˜ƒPOWER๎˜ƒOFF๎˜ƒ
The off๎˜ƒmeter๎˜ƒwill๎˜ƒswitch๎˜ƒ ๎˜ƒafter๎˜ƒ30๎˜ƒminutes๎˜ƒof๎˜ƒinactivity.๎˜ƒPress๎˜ƒany prevent๎˜ƒfunction๎˜ƒbutton๎˜ƒto๎˜ƒ ๎˜ƒthe๎˜ƒ
meter๎˜ƒfrom๎˜ƒpowering๎˜ƒoff;๎˜ƒthe auto timer๎˜ƒ ๎˜ƒ power off๎˜ƒ ๎˜ƒ ๎˜ƒ will๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒbe then be reset. The APO display
symbol๎˜ƒreminds that๎˜ƒthe๎˜ƒuser๎˜ƒ ๎˜ƒAuto๎˜ƒPower๎˜ƒOFF๎˜ƒis๎˜ƒalways๎˜ƒactive.๎˜ƒ
GERNERAL๎˜ƒUSE๎˜ƒ
๏‚ท All๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒLCD display lines will switch ON when power is applied to the meter. The bottom TVOC
display๎˜ƒwill๎˜ƒcount๎˜ƒdown๎˜ƒfrom๎˜ƒ10๎˜ƒseconds๎˜ƒor๎˜ƒfrom๎˜ƒ90๎˜ƒseconds๎˜ƒ(depending๎˜ƒon๎˜ƒthe๎˜ƒ
environment)๎˜ƒto๎˜ƒzero.๎˜ƒWhen๎˜ƒcountdown๎˜ƒis is๎˜ƒcomplete๎˜ƒthe๎˜ƒmeter๎˜ƒ ๎˜ƒready๎˜ƒfor๎˜ƒuse.๎˜ƒ
๏‚ท In๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒnormal mode, the top display indicates the HCHO concentration in PPM or mg/mยณ. The
bottom๎˜ƒ ๎˜ƒdisplay indicates๎˜ƒthe๎˜ƒTVOC๎˜ƒconcentration๎˜ƒin๎˜ƒPPM๎˜ƒor๎˜ƒ ๎˜ƒmg/mยณ.
๏‚ท Use๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒthe UNIT button to switch units between PPM and๎˜ƒmg/mยณ.๎˜ƒ
๏‚ท With๎˜ƒ ๎˜ƒ ๎˜ƒthe meter on,๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ โ€if the measured HCHO concentration exceeds the high or low user
programmable๎˜ƒAlarm๎˜ƒthresholds,๎˜ƒthe๎˜ƒLED๎˜ƒdisplay๎˜ƒwill๎˜ƒflash๎˜ƒred๎˜ƒin๎˜ƒcolor๎˜ƒand๎˜ƒthe๎˜ƒaudible๎˜ƒ
beeper๎˜ƒwill๎˜ƒsound๎˜ƒ(unless๎˜ƒit๎˜ƒhas๎˜ƒbeen๎˜ƒ ๎˜ƒdisabled with๎˜ƒthe๎˜ƒ ๎˜ƒSET/โ–ผbutton).๎˜ƒPress๎˜ƒSET/โ–ผ to๎˜ƒ
silence๎˜ƒthe the๎˜ƒalarm or๎˜ƒbeeper๎˜ƒ(when๎˜ƒit is๎˜ƒ ๎˜ƒ sounding)๎˜ƒ ๎˜ƒ to๎˜ƒ ๎˜ƒdisable ๎˜ƒbeeper๎˜ƒentirely.๎˜ƒWhen๎˜ƒ
disabled,๎˜ƒthe๎˜ƒ ๎˜ƒdisplayed beeper๎˜ƒsymbol๎˜ƒis๎˜ƒswitched๎˜ƒoff.๎˜ƒ
ALARM๎˜ƒSETUP๎˜ƒ(HCHO๎˜ƒonly)๎˜ƒ
Low๎˜ƒAlarm๎˜ƒSetup๎˜ƒ
1. the the Long๎˜ƒpress๎˜ƒ๎˜ƒSET/โ–ผ button๎˜ƒto๎˜ƒenter๎˜ƒ ๎˜ƒsetup๎˜ƒmode.๎˜ƒ
2. the LCD the The๎˜ƒlow icon๎˜ƒalarm๎˜ƒ ๎˜ƒwill๎˜ƒdisplay๎˜ƒand๎˜ƒ ๎˜ƒ ๎˜ƒwill๎˜ƒshow๎˜ƒ ๎˜ƒlow๎˜ƒalarm๎˜ƒthreshold.๎˜ƒ
3. the the Use๎˜ƒ ๎˜ƒ ๎˜ƒโ–ฒand๎˜ƒโ–ผ buttons๎˜ƒto๎˜ƒadjust๎˜ƒ ๎˜ƒlow๎˜ƒalarm๎˜ƒthreshold.๎˜ƒ
4. the Press๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒbutton to go to the high alarm setup screen.
High๎˜ƒAlarm๎˜ƒSetup๎˜ƒ
1. the the Use๎˜ƒ ๎˜ƒ ๎˜ƒโ–ฒand๎˜ƒโ–ผ buttons๎˜ƒto๎˜ƒadjust๎˜ƒ ๎˜ƒhigh๎˜ƒalarm๎˜ƒthreshold.๎˜ƒ
2. the the Press๎˜ƒ ๎˜ƒ ๎˜ƒbutton๎˜ƒto to๎˜ƒreturn๎˜ƒ ๎˜ƒ ๎˜ƒnormal๎˜ƒmeasurement๎˜ƒmode.๎˜ƒ


Specyfikacje produktu

Marka: Extech
Kategoria: Narzฤ™dzie wielofunkcyjne
Model: VFM200

Potrzebujesz pomocy?

Jeล›li potrzebujesz pomocy z Extech VFM200, zadaj pytanie poniลผej, a inni uลผytkownicy Ci odpowiedzฤ…




Instrukcje Narzฤ™dzie wielofunkcyjne Extech

Extech

Extech VFM200 Instrukcja

21 Sierpnia 2024

Instrukcje Narzฤ™dzie wielofunkcyjne

Najnowsze instrukcje dla Narzฤ™dzie wielofunkcyjne

Parkside

Parkside PAMFW 20-Li A1 Instrukcja

15 Paลบdziernika 2024
Gรผde

Gรผde GGF 620 Instrukcja

14 Paลบdziernika 2024
Makita

Makita DTM52Z Instrukcja

9 Paลบdziernika 2024
Ozito

Ozito PXPPHTK-258 Instrukcja

8 Paลบdziernika 2024
Powerfix

Powerfix PMW 2 B1 Instrukcja

8 Paลบdziernika 2024
Worx

Worx WX822L Instrukcja

8 Paลบdziernika 2024
Ozito

Ozito PXGMTK-2536 Instrukcja

7 Paลบdziernika 2024
Einhell

Einhell BT-MG 180/1 Instrukcja

7 Paลบdziernika 2024
Lezyne

Lezyne Tool Insert Kit Instrukcja

4 Paลบdziernika 2024
Lezyne

Lezyne Multi Chain Pliers Instrukcja

4 Paลบdziernika 2024