Setup Mode
Basic settings at a glance
To view the current conguration of the meter with regard to time, date, and datalogging sampling
rate press the SET button momentarily. The meter will now display the conguration in quick
succession. If the information is missed on the rst try, simply press the SET button again until all of
the information is noted.
Accessing the Setup mode
1. Press and hold the SET button for at least 1.5 seconds to access the Setup menu.
2. Press the SET button momentarily to step through the available parameters. The parameter
type is shown on the bottom of the LCD and the current selection for that type is shown above
it.
3. When a parameter is displayed that is to be changed, use the arrow keys to change the
setting. Press the ENTER button to conrm a change.
4. Press and hold the SET button for at least 1.5 seconds to exit the Setup mode. Note that the
meter automatically switches out of the Setup mode if no key is pressed within 7 seconds.
5.
The available Setup parameters are listed below. Additional detailed information is provided
below this list:
dAtE
Set the clock (Year/Month/Date; Hours/Minutes/Seconds)
SP-t
Set the datalogger sampling rate (Hours/Minutes/Seconds)
PoFF
Automatic power-off management (Enable or disable the auto-power o function)
bEEP
Set the beeper sound ON/OFF
dEC
Set the numerical format; USA (decimal: 20.00) or European (comma: 20,00)
Sd F
Format the SD memory card
t-CF
Units of measure selection for temperature readings (C or F)
tYPE
Select the Thermocouple type (K or J)
Setting the Clock Time
1. Access the dAtE parameter as described in the Accessing Setup Mode section above.
2. Use the arrow keys to change a value.
3. Use the ENTER button to step through the selections.
4. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).
5. The clock will keep accurate time even when the meter is switched o. However, if the battery
expires the clock will have to be reset after fresh batteries are installed.
Setting the Datalogger Sampling Time (Rate)
1. Access the SP-t parameter as described in the Accessing Setup Mode section above.
2. The sampling rate can be set to ‘0’ seconds (for manual logging) or
1, 2, 5, 10, 30, 60, 120,
300, 600, 1800, 3600 seconds for auto logging.
Use the arrow keys to select the sampling rate.
3.
Press the ENTER button to confirm the entry.
4. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).

8 SDL400-EU-EN V1.2 9/12
Datalogging and PC Interface
Types of Data Recording
• Manual Datalogging: Manually log up to 99 readings onto an SD card via push-button press.
• Automatic Datalogging: Automatically log data onto an SD memory card where the number of
data points is virtually limited only by the card size. Readings are logged at a rate specied by
the user.
SD Card Information
• Insert an SD card (from 1G size up to 16G) into the SD card slot at the bottom of the meter. The
card must be inserted with the front of the card (label side) facing toward the rear of the meter.
• If the SD card is being used for the rst time it is recommended that the card be formatted and
the logger’s clock set to allow for accurate date/time stamping during datalogging sessions.
Refer to the Setup Mode section for SD card formatting and time/date setting instructions.
• European and USA numerical formats dier. The data on the SD card can be formatted for
either format. The meter defaults to USA mode where a decimal point is used to separate units
from tenths, i.e. . The European format uses a comma, i.e. 20.00 20,00. To change this setting,
refer to the Setup Mode section.
Manual Datalogging
In the manual mode the user presses the LOG button to manually log a reading onto the SD card.
1. Set the sampling rate to ‘0’ seconds as described in the Setup Mode section.
2. Press and hold the LOG button for at least 1.5 seconds and the lower portion of the display will
show P- ( = memory position number 1-99). n n
3. Momentarily press the LOG button to store a reading. The REC icon will ash each time a data
point is stored.
4. Use the and ▲ ▼ buttons to select one of the 99 data memory positions in which to record.
5. To exit the manual datalogging mode, press and hold the LOG button for at least 1.5 seconds.
The P icon will switch o. n
Specyfikacje produktu
Marka: | Extech |
Kategoria: | światłomierz |
Model: | SDL400 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Extech SDL400, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje światłomierz Extech

5 Września 2024

1 Września 2024

26 Sierpnia 2024

21 Sierpnia 2024

19 Sierpnia 2024

8 Sierpnia 2024

4 Lipca 2024
Instrukcje światłomierz
- światłomierz Voltcraft
- światłomierz Testo
- światłomierz Uni-T
- światłomierz Sekonic
- światłomierz Velleman
- światłomierz Pyle
- światłomierz Fluke
- światłomierz Testboy
- światłomierz Kyoritsu
- światłomierz Klein Tools
- światłomierz Quantum
- światłomierz Beha-Amprobe
- światłomierz Amprobe
- światłomierz KlikaanKlikuit
- światłomierz Steren
- światłomierz Gossen
- światłomierz Delta Ohm
- światłomierz PCE Instruments
Najnowsze instrukcje dla światłomierz

12 Stycznia 2025

31 Grudnia 2025

31 Grudnia 2025

28 Grudnia 2024

2 Października 2024

2 Października 2024

2 Października 2024

2 Października 2024

2 Października 2024

2 Października 2024