MADE IN CZECH REPUBLIC
The great advantage is the possibility of changing the reference room by simply relocating the transmitter
part, in which way an optimum temperature comfort can be achieved in the room heated. The coverage
of the set can reach up to 35 m. The receiver is equipped with a code self-learning system and the
E-EPROM memory, which can keep the code saved even at power failure. The possibility of setting up
to 4 time periods and temperatures for every day provides for optimum distribution of electric energy
for all week. An ideally selected program will help you to reduce heating costs by up to 30 %.
Receiver power supply 230 V/ 50 Hz.
Receiver with the CODE SELF-LEARNING
system and the E-EPROM memory (saving
the code even at power failure).
Two-wire connection to the boiler.
Indication LED for signalization of the
states
- power supply indication
- signal transmission / reception
- failure state
- relay closed.
receiver – wall-mounted
transmitter
Weekly program
4 temperature changes per every day
Programming by 30 minutes and 0.5 °C
Programming by day or Mon-Fri, Sat-Sun
or Mon-Sun
Hysteresis 0.5 °C
Possibility of short-term temperature
change
Key lock
Sum of boiler operating hours
Manual mode (MANU)
Permanent switch-off (OFF)
Anti-freeze mode (3 °C)
TEST function
Supplied by alkaline batteries
2 × 1.5 V/AA
- freely portable
- small dimensions
- simple operation
- possibility of using
the stand (included
in the delivery)
TWO-WAY COMMUNICATION
- providing for reliable signal transmission and
enabling return information acquisition.
2
RECEIVER CONTROL ELEMENTS
CODE LEARNING
230 V/50Hz
NL
To be used if the receiver memory has been erased – the red diode is ashing!
1) Push the receiver’s “FUNCTION BUTTON” for about 1.5 sec; the blue and red LEDs start
ashing alternately; and the receiver is awaiting the code (“learning mode”).
2) After insetting batteries into the transmitter (see page 3), push the Fce , button; select the tE:St
function with the / button and confi rm it with the i button (the message appears on the Ad:r
display); confi rm with the i button (the code will be sent to the receiver).
3) The code receipt in the receiver is indicated by simultaneous fl ashing of the blue and red LED; thus the
code has been learnt. After the code receipt, the output relay is switched several times to verify correct
function of BPT 102 (On/OFF is displayed on the transmitter).
Lifting off the front cover:
Fig.1 Fig.2
Indication LEDs:
GREEN LIT - correct connection to the mains
BLUE FLASHES shortly - during communication with the transmitter
RED FLASHING - empty E-EPROM memory
RED LIT - FAILURE (if no signal from the transmitter is received within approx. 6
hours, it switches to the “2-min-ON / 8-min-OFF” mode)
BLUE+ FLASHING ALTERNATELY - code learning modeRED
BLUE+ FLASHING SIMULTANEOUSLY - code has been learnedRED
BLUE+ LIT SIMULTANEOUSLY - memory erasure modeRED
ORANGE LIT - relay 1 switched
holes for mounting on KU/KP68
FUNCTION BUTTON
- short push (approx. 1 s) =
CODE-LEARNING mode
- long push (approx. 5 s) =
RESET (memory erasure)
output terminals for
the boiler
(potential-free
switching contact)
power supply
terminals
RECEIVER INSTALLATION
- Lift off the front cover of the receiver acc. to Fig. 1, 2.
- Fix the receiver to the wall (or directly to the wiring box).
- Switch off the main circuit breaker.
- Connect the receiver to the boiler according to the diagram (on the boiler, use the terminals for wires of
the room thermostat 2).
- Connect the receiver to the mains 230 V / 50 Hz.
- Switch on the main circuit breaker; the green LED lights up on the receiver; thus the receiver is ready
for further setting
Owing to disturbance of the signal reception, install the receiver (in the interior) as far as possible (no
less than 0.5 m) from big metal objects and outside high-current power lines! We recommend that the
installation be done by a person properly qualifi ed in electrical engineering!
Wiring diagram: BOILER
3
BATTERY REPLACEMENT
The necessity to replace the batteries is indicated by the “ bA:tt
symbol ashing on the display.
1) Remove the control part from the lower cover of the device (Fig. 5).
2) Replace the batteries. Heed the correct polarity indicated in the
battery compartment (Fig. 6). When the batteries have been
removed, the thermostat preserves all settings in the memory.
Always use alkaline batteries 2 x1,5 V type AA!
After replacement of the batteries, perform the TEST (see page 6)!
Recommendation: check the batteries before every heating season!
Dispose of old batteries in conformity with regulations on hazardous waste handling!
TRANSMITTER DECRIPTION
TRANSMITTER INSTALLATION
The transmitter must be located as far as possible from interference sources (TV, PC, etc.) and
must not be placed on a metal base. When locating it, pay attention to the thermal properties of the
given place.
- Lift off the back cover of the transmitter acc. to Fig. 5.
- Insert batteries (alkaline 2×1.5 V, type AA); the transmitter will be fully functional (batteries are not
included in the delivery).
- Snap on the back cover again.
- The transmitter is freely portable and can be located, for example, on the table. We recommend using
of the stand included in the delivery.
- If the thermostat is mounted on the wall, pay attention that no heavy-current power lines are led in its
vicinity!
DISPLAY AND CONTROL ELEMENTS DECRIPTION
Fig.4 Fig.5 Fig.6
Fce
i
/
: used for function selection
: selection of required temp. (in MANU)
: confi rmation button (ENTER)
information on current temperature
(tE:A), time (CL:O), sum of operating
hours (SU:MA) and day (dE:n)
: for movement in the menu and
temperature setting
1) Preset temperature program indication
2) Selected function – AUTO, MANU, PROG, etc.
3) Anti-freeze temperature (3 °C)
4) Temperature indication – comfortable ,
economical .
5) Required temperature display
1
2
3
4
5


Specyfikacje produktu

Marka: Elektrobock
Kategoria: termostat
Model: BT102

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Elektrobock BT102, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat Elektrobock

Instrukcje termostat

Najnowsze instrukcje dla termostat

Siemens

Siemens RDG100T Instrukcja

15 Października 2024
Junkers

Junkers TA 21E Instrukcja

14 Października 2024
Oreg

Oreg AT90E Instrukcja

9 Października 2024
Oreg

Oreg AT60E Instrukcja

9 Października 2024
Heatit

Heatit PRO Instrukcja

9 Października 2024
Heatit

Heatit MULTIREG6 Instrukcja

9 Października 2024
Avidsen

Avidsen HomeFlow W Instrukcja

9 Października 2024
ORNO

ORNO OR-SH-17701 Instrukcja

8 Października 2024
ORNO

ORNO OR-SH-17702 Instrukcja

8 Października 2024
STI

STI -9102 Instrukcja

8 Października 2024