Instrukcja obsługi Dux Proflo 50S124P
Dux
Kotły i bojlery
Proflo 50S124P
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Dux Proflo 50S124P (16 stron) w kategorii Kotły i bojlery. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/16

25L and 50L Electric Storage Water Heater
Owner’s Manual
Models: 25S124P, 25S136, N25S124P,
N25S136, 50S124P, 50S136,
N50S124P, N50S136
028299 Rev. C
Specications and materials may change without notice.
Effective for the above model numbers of electric storage water heaters manufactured and
sold after 1st March 2021.
For advice, repairs and service, call:
1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Installation Details
Owner’s Information
Warranty

Important Safety Information
Owner’s Manual – Proflo 25/50 Litre Water Heater
i028299 Rev. C
WARNING – THIS APPLIANCE
MAY DELIVER WATER AT HIGH
TEMPERATURE. REFER TO THE
PLUMBING CODE OF AUSTRALIA
(PCA), LOCAL REQUIREMENTS AND
INSTALLATION INSTRUCTIONS TO
DETERMINE IF ADDITIONAL DELIVERY
TEMPERATURE CONTROL
IS REQUIRED.
WARNING – FOR CONTINUED
SAFETY OF THIS APPLIANCE IT
MUST BE INSTALLED, OPERATED
AND MAINTAINED IN ACCORDANCE
WITH THE MANUFACTURER’S
INSTRUCTIONS.
This water heater is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the water
heater by a person responsible for their
safety.
Children should be supervised to ensure
they do not interfere with the water heater.
Ensure animals are supervised so they do
not interfere with the water heater.
DO NOT store chemicals or ammable
materials, or spray aerosols near this water
heater.
DO NOT modify this water heater.
DO NOT operate the water heater with any
panels or covers removed.
If the water heater is not used for two weeks
or more, a quantity of hydrogen (which is
highly ammable) may accumulate inside the
water heater tank.
To dissipate this gas safely it is
recommended that a hot tap be turned on
for several minutes at a sink, basin or bath,
but not a dishwasher, clothes washer or
other appliance.
During this procedure there must be no
smoking, open ame or any other electrical
appliance operating nearby. If hydrogen is
discharged through the tap it will probably
make a sound similar to air escaping.
RELIEF VALVE:
The Pressure & Temperature Relief (PTR)
Valve must be installed with the brass
reducer directly into a RP¾”(DN20) socket
marked “RELIEF VALVE”.
The PTR Valve rating is 1,000 kPa and
10 kW on 25L and 50L capacities.
The valve must not be tampered with or
removed. The water heater must not be
operated unless this valve is tted and in
working order.
The drain line from the PTR Valve must
be installed in a continuously downward
direction in a frost free environment.
The PTR Valve is to be operated regularly
to remove lime deposits and to verify it is
not blocked. The drain line tted to the PTR
Valve must be left open to the atmosphere.
DANGER – FAILURE TO OPERATE
THE PTR VALVE EASING LEVER AT
LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER
EXPLODING. CONTINUOUS LEAKAGE
OF WATER FROM THE VALVE MAY
INDICATE A PROBLEM WITH THE
WATER HEATER.

Important Safety Information
Owner’s Manual – Proflo 25/50 Litre Water Heater
ii
028299 Rev. C
The PTR Valve should be checked by
a licensed tradesperson for adequate
performance, or replaced at intervals not
exceeding 5 years, or less in areas where
local regulations apply.
It is normal for water to drip from the drain
line tted to the PTR Valve during heating
cycles.
Continuous leakage of water from the PTR
Valve may indicate a problem with the water
heater. This may be caused by excessive
water supply pressure, a faulty PTR Valve or
a faulty thermostat.
Turn off the water heater and contact Dux
After Sales and Service.
OVER-TEMPERATURE ENERGY
CUT-OUT:
The operation of the over-temperature
energy cut-out indicates a possibly
dangerous situation. Do NOT reset the
over-temperature energy cut-out until the
water heater has been serviced by a licensed
tradesperson.
ELECTRICAL SAFETY:
This water heater is designed for single
phase 230-240V a.c. supply only. The
electrical connection must comply with
Local Supply Authority Regulations and
AS/NZS 3000 (known as the Wiring
Rules). A means for disconnection must
be incorporated in the xed wiring in
accordance with the Wiring Rules.
If the power supply cord is damaged, it must
be replaced by the manufacturer, a service
agent or a similarly qualied person in order
to avoid a hazard.
Any electrical covers should be removed only
by a licensed tradesperson, and only after
the electrical supply to the water heater has
been isolated.
When the supply wiring has been
connected, ensure the wires are kept
lower than the terminal block.
Excess wire is not to be looped close to the
thermostat or tank.
In addition to the Pressure & Temperature
Relief Valve, electric storage water heaters
are tted with a combination thermostat and
over-temperature energy cut-out.
This device must not be tampered with
or removed. Replacement of this device
must only be carried out by a licensed
tradesperson or the manufacturer.
The water heater must not be operated
unless this device is tted and in working
order.
COLD WATER CONNECTION:
The water heater is intended to be
permanently connected to the water supply
main, and not connected by a hose-set.
This water heater is designed for direct
connection to water supply pressures of up
to 800 kPa on 25L and 50L capacities.
Where the mains pressure can exceed or
uctuate beyond this pressure, a pressure
reducing valve must be tted in the cold
water inlet supply.
Instructions explaining how the water heater
can be drained can be found on page 5.
Specyfikacje produktu
Marka: | Dux |
Kategoria: | Kotły i bojlery |
Model: | Proflo 50S124P |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Dux Proflo 50S124P, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kotły i bojlery Dux

8 Grudnia 2024

8 Grudnia 2024

14 Września 2024

14 Września 2024

14 Września 2024

13 Września 2024

13 Września 2024

13 Września 2024

13 Września 2024

13 Września 2024
Instrukcje Kotły i bojlery
- Kotły i bojlery Tesy
- Kotły i bojlery Electrolux
- Kotły i bojlery AEG
- Kotły i bojlery Beko
- Kotły i bojlery Teka
- Kotły i bojlery Gorenje
- Kotły i bojlery LERAN
- Kotły i bojlery Philips
- Kotły i bojlery Morco
- Kotły i bojlery Dometic
- Kotły i bojlery Bosch
- Kotły i bojlery Whirlpool
- Kotły i bojlery Ferroli
- Kotły i bojlery Midea
- Kotły i bojlery Hisense
- Kotły i bojlery Infiniton
- Kotły i bojlery Panasonic
- Kotły i bojlery Adler
- Kotły i bojlery Rinnai
- Kotły i bojlery GE
- Kotły i bojlery Taurus
- Kotły i bojlery Orbegozo
- Kotły i bojlery Siemens
- Kotły i bojlery Haier
- Kotły i bojlery Jocel
- Kotły i bojlery Concept
- Kotły i bojlery Remeha
- Kotły i bojlery Truma
- Kotły i bojlery CATA
- Kotły i bojlery Hotpoint
- Kotły i bojlery Ariston Thermo
- Kotły i bojlery Intergas
- Kotły i bojlery Daikin
- Kotły i bojlery Kospel
- Kotły i bojlery Buderus
- Kotły i bojlery Corbero
- Kotły i bojlery Viessmann
- Kotły i bojlery Fagor
- Kotły i bojlery Vaillant
- Kotły i bojlery Waeco
- Kotły i bojlery Eta
- Kotły i bojlery Camry
- Kotły i bojlery Qlima
- Kotły i bojlery HTW
- Kotły i bojlery Dimplex
- Kotły i bojlery Baxi
- Kotły i bojlery Arçelik
- Kotły i bojlery Worcester
- Kotły i bojlery Atag
- Kotły i bojlery Franke
- Kotły i bojlery Rommer
- Kotły i bojlery Inventum
- Kotły i bojlery SVAN
- Kotły i bojlery Solac
- Kotły i bojlery Mora
- Kotły i bojlery VOX
- Kotły i bojlery Junkers
- Kotły i bojlery ACV
- Kotły i bojlery Aspes
- Kotły i bojlery Hitachi
- Kotły i bojlery Respekta
- Kotły i bojlery Technika
- Kotły i bojlery Rommelsbacher
- Kotły i bojlery Quantum
- Kotły i bojlery Kelvinator
- Kotły i bojlery Sencor
- Kotły i bojlery Kunft
- Kotły i bojlery Guzzanti
- Kotły i bojlery De Dietrich
- Kotły i bojlery Nefit
- Kotły i bojlery A.O. Smith
- Kotły i bojlery Easypix
- Kotły i bojlery Stiebel Eltron
- Kotły i bojlery Elco
- Kotły i bojlery Masterwatt
- Kotły i bojlery Nibe
- Kotły i bojlery Elba
- Kotły i bojlery Buffalo
- Kotły i bojlery TTulpe
- Kotły i bojlery Atlantic
- Kotły i bojlery Plieger
- Kotły i bojlery Bulex
- Kotły i bojlery AWB
- Kotły i bojlery Quooker
- Kotły i bojlery OSO
- Kotły i bojlery La Nordica
- Kotły i bojlery Clage
- Kotły i bojlery Noveen
- Kotły i bojlery Joven
- Kotły i bojlery Daalderop
- Kotły i bojlery Fakir
- Kotły i bojlery Cointra
- Kotły i bojlery Eccotemp
- Kotły i bojlery Biasi
- Kotły i bojlery Thermor
- Kotły i bojlery Sentry
- Kotły i bojlery Country Comfort
- Kotły i bojlery Keston
- Kotły i bojlery Burco
- Kotły i bojlery Khind
- Kotły i bojlery LEMET
- Kotły i bojlery Duwaco
- Kotły i bojlery Wesen
- Kotły i bojlery Rheinstrom
- Kotły i bojlery Wagaparts
- Kotły i bojlery SolarEdge
- Kotły i bojlery IQE
- Kotły i bojlery Wahlbach
- Kotły i bojlery Ygnis
- Kotły i bojlery Intellihot
- Kotły i bojlery Airthereal
- Kotły i bojlery Thermoflow
- Kotły i bojlery IStore
- Kotły i bojlery Apricus
- Kotły i bojlery Aquamarin
- Kotły i bojlery Sime
- Kotły i bojlery Hydrotherm
- Kotły i bojlery Amtrol
- Kotły i bojlery Neopower
- Kotły i bojlery Gleamous
- Kotły i bojlery AquaMAX
- Kotły i bojlery My-PV
- Kotły i bojlery EvoHeat
- Kotły i bojlery Rheem
- Kotły i bojlery Solahart
- Kotły i bojlery ENEFT
- Kotły i bojlery Imarflex
- Kotły i bojlery MicroHeat
- Kotły i bojlery Noritz
Najnowsze instrukcje dla Kotły i bojlery

13 Stycznia 2025

13 Stycznia 2025

12 Stycznia 2025

12 Stycznia 2025

12 Stycznia 2025

9 Stycznia 2025

9 Stycznia 2025

9 Stycznia 2025

9 Stycznia 2025

9 Stycznia 2025