Lithium/Manganese Dioxide
Ultra CR2
Li/MnO2
6/08
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
*
Nominal Voltage: 3.0 V
Typical Voltage: 3.2-3.3 V
Nominal Internal
Impedance: 0.3 ohm @ 1kHz
Average Weight: 11 g
Volume: 5.168 cm.3
Terminals: Flat, Recessed Negative
Terminal, Nickel Plated Steel
Operating Temp.
Range:
-20°C to 75°C (-4°F to
167°F)
NEDA/ANSI : CR2
IEC: -
Duracell Ultra CR2 Typical Performance
0 400 800 1200
Pulse Cycles
Photo
35mm SLR Photo
35mm Point &
Shoot Camera
1.2A, 3 sec on 7sec off, cont.
to 1.8 V @ 20°C
1.8A, 3 sec on 7sec off, cont.
to 1.8 V @ 20°C
0.9A, 3 sec on 27sec off, cont.
to 1.8 V @ 20°C
Dimensions shown are ANSI standards
(–)
(+)
0.7 mm
Min
27.0 mm
Max
15.6 mm
15.1
6.5 mm
Max
Delivered Energy vs. Power Drain
@ Various Cuto Voltage - Room Temperature
0.1
1
3
411.0
Power (W)
Energy (Wh)
1.8 V
2.0 V
2.2 V
6/08
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Lithium/Manganese Dioxide
Ultra CR2
Li/MnO2
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.duracell.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
*
0.9 Amp, 3 sec on/27 sec o
@ Various Temperatures
1.5
1.9
2.3
2.7
00210080040
Pulses
Battery Voltage (V)
RT
1.2 Amp, 3 sec on/ 7 sec o
@ Various Temperatures
1.5
1.9
2.3
2.7
0080060040020
Pulses
Battery Voltage (V)
RT
1.8 Amp 3 sec on/ 7 sec o
@ Various Temperatures
1.5
1.9
2.3
2.7
0 100 200 300 400 500
Pulses
Service Hours (V)
RT
-10C
-10C
-10C
- 20C
- 20C
Continuous Discharge RT to 1.7 Volts
1
2
3
4
0020010111.0
Service (Hours)
Voltage (V)
10 mA
50 mA
100 mA
250 mA
500 mA
750 mA
1000 mA


Specyfikacje produktu

Marka: Duracell
Kategoria: Akumulator
Model: CR2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Duracell CR2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Akumulator Duracell

Duracell

Duracell CR123 Instrukcja

5 Października 2024
Duracell

Duracell CR2 Instrukcja

5 Października 2024
Duracell

Duracell 5+ Instrukcja

26 Września 2024

Instrukcje Akumulator

Najnowsze instrukcje dla Akumulator