Instrukcja obsługi DSC HS2LCDWFP9
DSC
System kontroli dostępu
HS2LCDWFP9
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla DSC HS2LCDWFP9 (79 stron) w kategorii System kontroli dostępu. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/79
HS2LED/HS2ICON(P)(RF)X/HS2LCD(RF)(P)X V1.3
Installation Instructions/Instructions d’installation/Instrucciones de
instalación/Instruções de instalação English, Français, Español, Português
29009811R002
Introduction
The HS2LED/HS2ICN(P)(RF)x/HS2LCD(RF)(P)x keypads are compatible
with the PowerSeries Neo HS2016/32/64, HS2016-4* and HS2128 panels.
The RF keypads combine a wireless transceiver with the respective HS2
keypad.
*Model not UL/ULC listed.
Specifications
lTemperature range: -10°C to +55°C (14°F to 131°F); UL/ULC: 0°C
to +49°C (32°F to 120°F)
lHumidity (MAX): 93%R.H. non-condensing
lPlastic enclosure protection degree: IP30, IK04
lVoltage rating: 13.8Vdc nominal (power provided by the compatible
control panel)
lConnects to control panel Corbus via 4 wires
l1 configurable zone input or PGM output*
lHS2LED/ HS2ICN(P)/HS2LCD(P)/HS2ICNRF(P)/HS2LCDRF(P)
Current draw:55mA(min)/105mA(max)
lWall-mount tamper
l5 programmable function keys
lReady (Green LED), Armed (Red LED), Trouble (Yellow LED),
AC (Green LED)
lDimensions (L x W x D): 168mm x 122mm x 20 mm
lWeight: 260g
lLow temperature sensor
lFrequency: 433 MHz (HS2ICNRF4/HS2LCDRF4)
l868 MHz (HS2ICNRF8/HS2LCDRF8)
l912-919MHz (HS2ICNRF9/HS2LCDRF9)
lUp to 128 wireless zones
Zone not to be programmed as Fire type or 24h type.
NOTE: Keypads contain no serviceable parts.
NOTE: Only models operating in band 912-919MHz are UL/ULC listed.
Unpack
The keypad package includes the following:
HS2LED/ICN(RF)/LCD(RF) HS2ICN(RF)P/LCD(RF)P
1 keypad 1 keypad
4 mounting screws 4 mounting screws
2 end-of-line resistors 2 end-of-line resistors
Keypad inner door labels Keypad inner door labels
1 tamper switch 1 tamper switch
Installation Instructions Installation Instructions
Mini Proximity (prox) tag (MPT)
Table 1: Compatible Devices
Wireless PG smoke detector PGx926UL
Wireless PG smoke and heat detector PGx916UL
Wireless PG CO detector PGx913
Wireless PG PIR moti on detector PGx904(P)UL
Wireless PG PIR + camera motion detector PGx934(P)UL
Wireless PG curtain motion detector PGx924UL
Wireless PG dual tech motion detector PGx984(P)
Wireless PG mirror motion detector PGx974(P)UL
Wireless PG outdoor motion detector PGx994UL
Wireless PG glass break detector PGx912/PGX922 UL
Wireless PG shock detector PGx935UL
Wireless PG flood detector PGx985UL
Wireless PG temperature detector (indoor) PGx905UL
Outdoor temperature probe (requires PGx905) PGTEMP-PROBE
Wireless PG key PGx939UL
Wireless PG key PGx929UL
Wireless PG panic key PGx938UL
Wireless PG 2-button key PGx949UL
Wireless PG indoor siren PGx901UL
Wireless PG outdoor siren PGx911UL
Wireless PG repeater PGx920UL
Wireless PG door/window contact PGx975UL
Wireless PG door/window contact w/AUX PGx945UL
NOTE: In this chart, x in the model number represents the operating fre-
quency of the device as follows: 9 (912-919 MHz), 8 (868MHz), 4
(433MHz).
NOTE: Only models operating in the band 912-919 MHz are UL/ULC or
cUL listed where indicated. Only UL approved devices are to be used
with UL/ULC listed systems.
Mount the Keypad
Mount the keypad where it is accessible from designated points of entry
and exit. Once a dry and secure location has been selected, perform the fol-
lowing steps to mount the keypad.
Disassemble Keypad
Insert the tip of a flat-head screwdriver into the slots at the bottom left
and right of the keypad.
Gently pry open the faceplate. This will remove it and allow access for
mounting.
Mount and Wire Keypad
1. Secure keypad to wall using mounting holes. Use all four screws
provided unless mounting on a single gang box. Use the plastic anchors
supplied if the unit is to be mounted on drywall.
2. If using the keypad tamper, secure the tamper plate to the wall with a
screw.
NOTE: For UL/ULC listed commercial burglary installations, the use of
the keypad tamper is mandatory.
3. Run wire through wiring slot or knockouts. Connect Corbus and
PGM/Zone wiring to keypad. Place tamper switch into tamper hole on
backplate.
4. Place keypad into backplate, ensuring the wire is pushed back into the
wall as much as possible. Route the wire inside the keypad, ensuring high
components are avoided. Snap the front assembly closed, ensuring that
there is no pressure to the keypad from the wire below.
Specyfikacje produktu
Marka: | DSC |
Kategoria: | System kontroli dostępu |
Model: | HS2LCDWFP9 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z DSC HS2LCDWFP9, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje System kontroli dostępu DSC
5 Lipca 2024
Instrukcje System kontroli dostępu
- System kontroli dostępu Hikvision
- System kontroli dostępu Viking
- System kontroli dostępu Vimar
- System kontroli dostępu Dahua Technology
- System kontroli dostępu Delta Dore
- System kontroli dostępu Panduit
- System kontroli dostępu Speco Technologies
- System kontroli dostępu Chief
- System kontroli dostępu Assa Abloy
- System kontroli dostępu Axis
- System kontroli dostępu Abus
- System kontroli dostępu Marmitek
- System kontroli dostępu ZKTeco
- System kontroli dostępu Yale
- System kontroli dostępu Acti
- System kontroli dostępu Techly
- System kontroli dostępu Steren
- System kontroli dostępu Safescan
- System kontroli dostępu Iget
- System kontroli dostępu EverFocus
- System kontroli dostępu Satel
- System kontroli dostępu Provision ISR
- System kontroli dostępu Suprema
- System kontroli dostępu HID Identity
- System kontroli dostępu Indexa
- System kontroli dostępu ONE Smart Control
- System kontroli dostępu Approx
- System kontroli dostępu Gewiss
- System kontroli dostępu SOREX
- System kontroli dostępu Atlantis Land
Najnowsze instrukcje dla System kontroli dostępu
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024