Instrukcja obsługi DeLonghi Pinguino PAC C120E

DeLonghi klimatyzacja Pinguino PAC C120E

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla DeLonghi Pinguino PAC C120E (14 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/14
4
Important safeguards
DESCRIPTION
1air outlet grille
2control panel
3castor wheels
4 handles
5filter
6 air intake grille
7air exhaust hose housing
8drainage hose
9 power cable
10 wall flange
11 air exhaust hose
12 window outlet
13 castor locks
14 remote control
15 window bracket with locking pins
Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many situations as possible.
Caution and common sense should be used when operating and installing this air conditioner.
This appliance has been manufactured to cool and dehumidify domestic environments and
must not be used for other purposes.
It is dangerous to alter or modify the unit's characteristics in any way.
The appliance must be installed in accordance with the relevant national legislation.
Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
rized servicing can be dangerous.
The appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the power cable is damaged, it must be replaced by the manufacturer or an authorized
technical service centre in order to avoid all risk.
Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts
check with a qualified electrician.
Do not use extension cables.
Before cleaning or maintenance operations, always unplug the unit from the outlet.
Do not pull on or place strain on the power cord when moving the appliance.
The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
Do not rest hot or heavy objects on the appliance.
Clean the filters at least once a week.
Avoid using heaters near the unit.
The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie it horizontally.
Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before
switching the unit on.
The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.
This appliance is fitted with a special safety device. When the compressor switches off, this
device prevents it from switching on again for at least 3 minutes.
WARNING: Changes or modifications not expressly approved by the party responsible for com-
pliance could void the user's authority to operate the equipment.
SPECIFIC WARNINGS FOR APPLIANCES WITH R410A REFRIGERANT GAS
R410A refrigerant gas conforms to EC regulations on the environment.
Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION:
This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).
.SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
5
GB
GB
GB
GBGB
Setting up your portable
air conditioner
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT
6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit has
been on its side, oil needs to return to the compressor to ensure proper function. Without allow-
ing the unit this time (6-24 hours) the unit may function for only a short time, and then the com-
pressor will break down from lack of oil.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the outlet, check that:
The outlet’s power supply corresponds to the value indicated on the rating label on the back
of the appliance;
The outlet and electrical circuit are adequate for the appliance;
The outlet is a 3-hole grounded outlet . If this is not the case, you must choose another outlet.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The instructions below will enable you to prepare your air conditioner for operation as efficiently
as possible. Before use, make sure the air intake and outlet grilles are unobstructed.
If it becomes necessary, the power cable must be replaced by a qualified professional only.
Other set-up methods:
Thanks to the locking pins, it’s possible to
use the window bracket also for sliding
windows. Position the hole of the bracket
so to allow a correct installation of the
exhaust hose (see figure C).
If you have a casement window (figure D)
follow steps 2 & 3 and place the window
outlet ( ) outside the window to exhaust12
the hot air.
For help with installation, operation, and
for all accessories and spare/replacement
parts, Please contact our toll free cus-
tomer service call center at:
1-800-322-3848 [US only]
Monday Friday 8:30am 5:00pm ET Or
log onto our website at
www.delonghiusa.com.
AIR CONDITIONING WITHOUT INSTALLATION
NOTE: Keep the air hoses as short and free of
curves as possible to avoid constrictions.
FOR OPTIMAL RESULTS SET-UP IN A DOU-
BLE-HUNG WINDOW:
1) Place the bracket in the window sill,
extend the bracket fully within the window
frame, fix the bracket by using the pin
then lower the window onto the bracket.
(Should the window bracket be too large
for the window. The plastic can be cut
with a saw by a qualified professional.)
2) Fit the air exhaust hose in the housing at
the back of the appliance. Insert it as
shown in figure A.
3) Connect the window outlet ( ) to the12
other end of the exhaust hose.
4) Insert the window outlet end of the exhaust
hose into the slot of the window bracket (fig. B).
A
B
C
D
in the
window
pane
in the wall:
you are
recommended
to insulate the
section of wall
using suitable
insulation.
in the
wooden
kickboard
of a
French
window
F
Semi-permanent installation
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be
installed semi-permanently (Fig. E).
Proceed as follows:
Drill a hole ø 5,25 inches (134 mm) in an
outside wall or through a window pane.
Respect the dimensions and height of the
hole given in figure F Gand .
Fit the wall flange ( ) into the hole.10
Fit the air exhaust hose (11) in the rele-
vant housing located on the rear side of
the appliance. (fig. page 5).A
Fit the end of the hose (11) to the wall
flange (10) as shown in fig. G.
When the hose ( ) is not connected, the dril-11
led hole can be closed with the flange cap
(10).
NOTE: When installing the air conditioner
semi-permanently, you should leave a door
slightly open little as 1/2 (1 cm) to guar-
antee correct ventilation and room pressure.
6
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
“As special tools are required for installa-
tion, we suggest you have the applian-
ce installed by specialized personnel.”
E
G


Specyfikacje produktu

Marka: DeLonghi
Kategoria: klimatyzacja
Model: Pinguino PAC C120E

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z DeLonghi Pinguino PAC C120E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja DeLonghi

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024