OPERATION MANUAL
EWLP012KBW1N
EWLP020KBW1N
EWLP026KBW1N
EWLP030KBW1N
EWLP040KBW1N
EWLP055KBW1N
EWLP065KBW1N
Condenserless water-cooled water chillers
Operation manual
1
EWLP012~065KBW1N
Condenserless water-cooled water chillers
4PW61666-1A – 2012.04
CONTENTS Page
Introduction ....................................................................................... 1
Technical specifications ............................................................................. 2
Electrical specifications ............................................................................. 2
Description ........................................................................................ 3
Function of the main components.............................................................. 4
Safety devices............................................................................................ 4
Internal wiring - Parts table ........................................................................ 5
Before operation................................................................................ 6
Checks before initial start-up ..................................................................... 6
Water supply.............................................................................................. 6
Power supply connection and crankcase heating...................................... 6
General recommendations ........................................................................ 6
Operation .......................................................................................... 6
Digital controller......................................................................................... 6
Working with the units................................................................................ 7
Advanced features of the digital controller............................................... 10
BMS connection modbus ................................................................ 13
General description of Modbus................................................................ 13
Implemented error code........................................................................... 14
Defining the BMS setting ......................................................................... 14
Variables database .................................................................................. 14
Troubleshooting ............................................................................... 15
Maintenance.................................................................................... 16
Important information regarding the refrigerant used .............................. 16
Maintenance activities ............................................................................. 16
Disposal requirements ............................................................................. 16
Annex I ............................................................................................ 17
Saturated temperature............................................................................. 17
Menu overview ................................................................................ 18
The English text is the original instruction. Other languages are
translations of the original instructions.
This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
INTRODUCTION
This operation manual concerns condensorless water-cooled water
chillers of the Daikin EWLP-KB series. These units are provided for
indoor installation and used for cooling applications. The EWLP units
can be combined with Daikin fan coil units or air handling units for air
conditioning purposes. They can also be used for supplying water for
process cooling.
This manual has been prepared to ensure adequate operation and
maintenance of the unit. It will tell you how to use the unit properly
and will provide help if problems occur. The unit is equipped with
safety devices, but they will not necessarily prevent all problems
caused by improper operation or inadequate maintenance.
In case of persisting problems contact your local Daikin dealer.
EWLP012KBW1N EWLP040KBW1N
EWLP020KBW1N EWLP055KBW1N
EWLP026KBW1N EWLP065KBW1N
EWLP030KBW1N
Condenserless water-cooled water chillers Operation manual
READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW THIS MANUAL AWAY.
KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.
Read the chapter "Operation" on page 6 before changing
the parameters.
Before starting up the unit for the first time, make sure that
it has been properly installed. It is therefore necessary to
carefully read the installation manual supplied with the unit
and the recommendations listed in "Before starting".
EWLP012~065KBW1N
Condenserless water-cooled water chillers
4PW61666-1A – 2012.04
Operation manual
2
Technical specifications
(1) Electrical specifications(2)
(1) Refer to the engineering data book for the complete list of specifications.
General EWLP 012 020 026 030
Dimensions HxWxD 600x600x600(mm)
Machine weight (kg) 104 138 144 149
Connections
• condenser
discharge
connection
(copper)
(mm) 12.7 flare 19.1 flare 19.1 flare 19.1 flare
• condenser liquid
connection
(copper)
(mm) 9.52 flare 12.7 flare 12.7 flare 12.7 flare
General EWLP 040 055 065
Dimensions HxWxD 600x600x1200(mm)
Machine weight (kg) 252 265 274
Connections
• condenser
discharge
connection
(copper)
(mm) 2x 19.1 flare 2x 19.1 flare 2x 19.1 flare
• condenser liquid
connection
(copper)
(mm) 2x 12.7 flare 2x 12.7 flare 2x 12.7 flare
Compressor EWLP 012 020 026 030
Model JT140BF-YE JT212DA-YE JT300DA-YE JT335DA-YE
Speed (rpm) 2900
Oil type FVC68D
Oil charge volume (l) 1.5 2.7 2.7 2.7
Refrigerant type R407C
Evaporator
Type brased plate heat exchanger
Min. water volume (l) 62.1 103 134 155
Water flow range (l/min) 31~69 53~115 65~153 76~179
Condenser
refer to engeneering specifications as published by the supplier of your
remote condenser
Compressor EWLP 040 055 065
Model 2x
JT212DA-YE
2x
JT300DA-YE
2x
JT335DA-YE
Speed (rpm) 2900
Oil type FVC68D
Oil charge volume (l) 2x 2.7 2x 2.7 2x 2.7
Refrigerant type R407C
Evaporator
Type brased plate heat exchanger
Min. water volume (l) 205 268 311
Water flow range (l/min) 101~229 131~307 152~359
Condenser
refer to engeneering specifications as published by the supplier of your
remote condenser
(2) Refer to the engineering data book for the complete list of specifications.
Model EWLP 012 020 026 030
Power supply
• Phase 3N~
• Frequency (Hz) 50
• Voltage (V) 400
• Voltage tolerance (%) ±10
• Recommended fuses (aM) 3x 16 3x 20 3x 25 3x 32
Compressor
• Phase 3~
• Frequency (Hz) 50
• Voltage (V) 400
• Nominal running current (A) 7.4 11.6 14.7 16.8
Control
• Phase 1~
• Frequency (Hz) 50
• Voltage (V) 230
• Recommended fuses (aM) factory installed
Model EWLP 040 055 065
Power supply
• Phase 3N~
• Frequency (Hz) 50
• Voltage (V) 400
• Voltage tolerance (%) ±10
• Recommended fuses (aM) 3x 40 3x 50 3x 50
Compressor
• Phase 3~
• Frequency (Hz) 50
• Voltage (V) 400
• Nominal running current (A) 11.6 14.7 16.8
Control
• Phase 1~
• Frequency (Hz) 50
• Voltage (V) 230
• Recommended fuses (aM) factory installed
Operation manual
3
EWLP012~065KBW1N
Condenserless water-cooled water chillers
4PW61666-1A – 2012.04
DESCRIPTION
The EWLP condenserless water-cooled water chillers are available in 7 standard sizes.
Figure: Main components
13 14 15 16
17
500
500
500
5
10
2
3
1 4
10
11 11
9
2
3
4
3
1
1
7 59
8 66 1818
12 12
7
8
500
500
500
500500
EWLP012~030KBW1N
EWLP040~065KBW1N
1Compressor
2Evaporator
3Accumulator
4Switchbox
5Chilled water in
6Chilled water out
7Discharge stop valve
8Liquid stop valve
9Evaporator entering water temperature sensor
10 Freeze up sensor
11 Digital display controller
12 Power supply intake
13 Ball valve (field installed)
14 Water filter (field installed)
15 Air purge valve (field installed)
16 T-joint for air purge (field installed)
17 Flow switch (with T-joint) (field installed)
18 Main switch
Required space around the unit for service
EWLP012~065KBW1N
Condenserless water-cooled water chillers
4PW61666-1A – 2012.04
Operation manual
4
Function of the main components
Figure: Functional diagram
As the refrigerant circulates through the unit, changes in its state or
condition occur. These changes are caused by the following main
components:
Compressor
The compressor (M*C) acts as a pump and circulates the
refrigerant in the refrigeration circuit. It compresses the
refrigerant vapour coming from the evaporator to a pressure at
which it can easily be liquified in the condenser.
Filter
The filter installed behind the condenser removes small particles
from the refrigerant to prevent blockage of the tubes.
Expansion valve
The liquid refrigerant coming from the condenser enters the
evaporator via an expansion valve. The expansion valve brings
the liquid refrigerant to a pressure at which it can easily be
evaporated in the evaporator.
Evaporator
The main function of the evaporator is to take heat from the
water that flows through it. This is done by turning the liquid
refrigerant, coming from the condenser, into gaseous refrigerant.
Water in/outlet connections
The water inlet and outlet connection allow an easy connection
of the unit to the water circuit of the air handling unit or industrial
equipment.
Safety devices
The unit is equipped with General safety devices: shut down all
circuits and stop the whole unit.
I/O PCB (A2P) (input/output)
The I/O PCB (A2P) contains a reverse phase protector.
The reverse phase protector detects if the 3 phases of the power
supply are connected correctly. If a phase is not connected or if
2 phases are inverted, the unit can not start up.
Overcurrent relay
The overcurrent relay (K*S) is located in the switch box of the
unit and protects the compressor motor in case of overload,
phase failure or too low voltage. The relay is factory-set and may
not be adjusted. When activated, the overcurrent relay has to be
reset in the switch box and the controller needs to be reset
manually.
High-pressure switch
The high-pressure switch (S*HP) is installed on the discharge
pipe of the unit and measures the condenser pressure (pressure
at the outlet of the compressor). When the pressure is too high,
the pressure switch is activated and the circuit stops.
When activated, it resets automatically, but the controller needs
to be reset manually.
1 9Compressor Liquid stop valve
2 10Filter Discharge stop valve
3Expansion valve Accumulator11
4 12Evaporator Flow switch (delivered with the unit, installed in the field)
5Evaporator water outlet Ball valve (delivered with the unit, installed in the field)13
6Evaporator water inlet Water filter (delivered with the unit, installed in the field)14
7 15Sight glass Air purge valve (delivered with the unit, installed in the field)
8Liquid solenoid valve Field piping
S4LP
S1HP
R3T
Q1D
HP
LP
M1C
R4T
1
5
6 4
2
10111513
13
14
3 7
S5LP
S2HP
Q2D
HP
LP
M2C
12
R3T
R4T S4LP
HP
LP
M1C S1HP
Q1D
8 9
EWLP012~030KBW1N
EWLP040~065KBW1N


Specyfikacje produktu

Marka: Daikin
Kategoria: Sprzęt komputerowy
Model: EWLP040KBW1N

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Daikin EWLP040KBW1N, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt komputerowy Daikin

Instrukcje Sprzęt komputerowy

Najnowsze instrukcje dla Sprzęt komputerowy