Pacific TOUGH C240 DDC Hard Tube LIQUID COOLING KIT
CL-W 30 5-CU12 BL -A
01 02 03
x 1 x 2 x 1
09 x 1 10 x 1
04 05 06 07 08 x 4 x 4 x 4 x 4 x 4
Parts List
This product is intended for installation only by expert users. Please consult with a qualified technician for installation.
Improper installation may result in damage to your equipment. Before you start using this product please follow these basic guidelines:
1. Please carefully read the manual before beginning the installation process !
2. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant.
3. Please remove your graphics card from your motherboard to ensure the safest process and in order to prevent any possible damages to your CPU and motherboard.
4. DO NOT USE any kind of alcohol or alcohol derivatives with this reservoir or the acrylic tube may crack and fail ! Do not clean it using alcohol either !
11 12 13 14 15 16 17 x 1 x 2 x 6 x 6 x 4 x 1 x 2
CPU Water Block
Pump / Reservoir
Fan & Radiator
Accessory
20 x 1
18 x 4
19 x 2
25 26 x 2 x 6 27 x 8 28 x 1
29 30 31 32 x 1 x 1 x 1 x 1
21 22 23 24 x 8 x 8 x 8 x 1
1
Pacific TOUGH C240 DDC Hard Tube LIQUID COOLING KIT
CL-W305-CU12BL-A
AMD
Intel LGA2066,2011-3,2011
Intel LGA115x,LGA1200,LGA1366, LGA1700
CPU Water Block Installation Guide
© 2021 Thermaltake Technology Co., Ltd. All Rights Reserved.
www.thermaltake.com
2
05
07
01
1
1
1 3
2
2
2
4
06
10
03
04
01
05
07
08
10
02
09
06
10
03
04
09
05
07
01
1.FM2/FM1/AM3/AM2
2.AM4
3.LGA1366
4.LGA1700
5.LGA115X/1200
Pacific TOUGH C240 DDC Hard Tube LIQUID COOLING KIT
CL-W305-CU12BL-A
Installation Guide
CAUTIONS: 1. Make sure there is enough space when you start to set up the LCS product
2. Please use the wrench to install/ uninstall the base parts during all the installation
To ensure a clean loop, flush and rinse your radiators
and water blocks with distilled water before using.
Make sure the fittings are screwed securely when
placing them onto the radiator.
Attach the fittings to the inlet and outlet of the
water block.
Radiator
Fitting Water Block
Installation Walkthrough (Example: A500 TG)
Place the motherboard into the case. Position the radiator. Attach the pump and reservoir into
the chosen locations.
3
2
1
Nut
O Ring-
Packing
Base
Base
Dismantle the fitting by using the wrench
1
2
3
24 26
26
01
25
26
22
21
20
Attach the fans to the radiator
Case Fan
19
23
Connect the PWM
cable to motherboard. 28
Connect the fan power cable to PWM cable
1928
20
or
Choose the proper way to mount the pump and reservoir by
referring to the manual (suggest vertical placement) Attach fittings onto the pump and reservoir
Pump / Reservoir
25
26
26
11
11
Connect the fan power cable when the liquid cooling system
is completely finished
14
15
15
13
11
14
13
17
12


Specyfikacje produktu

Marka: Thermaltake
Kategoria: Sprzęt komputerowy
Model: Pacific TOUGH C240 DDC

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Thermaltake Pacific TOUGH C240 DDC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt komputerowy Thermaltake

Instrukcje Sprzęt komputerowy

Najnowsze instrukcje dla Sprzęt komputerowy