THERMEX
SPECIALIZED WATER HEATER MANUFACTURER
ELECTRIC WATER HEATER
OPERATION MANUAL
UNIQUE WELDING PRACTICE G.5
HIGH-QUALITY AUSTENITIC STAINLESS STEEL
www.thermex.ru
DEAR BUYER!
We wish to congratulate you on the purchase of electric water heater. It is THERMEX
safe to say that our wide range of electric water heaters will satisfy any of your needs. The use of
modern technologies and high-quality materials in the manufacture of these devices brought
about popularity of and confidence in THERMEX trade mark. Our electric water heaters can be
optionally equipped with a protective cutout device (PCD) to ensure complete electrical safety in
operation.
THERMEX electric water heaters are designed and manufactured in strict
correspondence with international standards that ensure reliability and safety in operation. The
models were all subjected to compulsory certification by the Russian State Standard and fully
comply with the requirements of -ГОСТР 51318.14.1 2006, ГОСТ Р 52161-2-21-2006.
This Manual covers THERMEX models (Series IR, IF, ID, IQ, IS, RZL). The model
name of the water heater you purchased is shown in Section on W “Manufacturer's arranties”
(Subsection on and on an identification plate on the device case. “Sales Mark”)
Please read over carefully this Operation Manual.
1. PURPOSE
The electric water heater (hereinafter referred to as EWH) is designed to supply hot water
to domestic and industrial facilities having a cold water main operating under a working pressure
of not less than 0.05 MPa and not more than 0.6 MPa.
The EWH is to be operated in enclosed heated rooms. It is not intended for use in continuous
flow mode.
2. ESSENTIAL TECHNICAL CHARACTERISTICS
Power supply voltage for all EWH types and models should be within 220v ± 10%.
Mains frequency must be 50 Hz ± 1%. Capacity of the inner tank and power of the heating
element are shown on identification plate on the device case A thread diameter of branch an .
pipes at the water inlet and outlet is 1/2 ".
Table 1
EWH Capacity,
L
Average heating time at ΔТ=45°С
(for W)Р = 2000
5
10
15
30
40
50
60
80
100
120
150
0 . 08 min. hr
0 . 15 min. hr
0 . 25 min. hr
0 . 50 min. hr
1 . 10 min. hr
1 . 25 min. hr
1 . 40 min. hr
2 hr. 10 min.
2 hr. 45 min.
3 15 min. hr.
4 hr. 10 min.
3. DELIVERY SET
1. Electric water heater with PCD 1 . (optionally - ) pc
2. Safety valve, type - 1 pc. GP
3. Operation Manual - 1 pc.
4. Securing anchor - 2 pcs per holding plate.
5. Packing -1 pc.
6. Remote control panel 1 pc. (optionally -)
4. EWH DESCRIPTION AND OPERATNG PRINCIPLE
4.1. The EWH outer case, depending on the model, is made of various high-quality materials
such as impact-resistant plastic, low-carbon or special bright-finished stainless steel. The inner
tank is made of stainless steel containing titanium to provide good corrosion resistance and, as a
result, long-term operation. The space between the outer case and the inner tank is filled with
polyurethane foam - a modern, environmentally safe insulation having the roved heat imp
preservation characteristics. Models RZL, IS-V, IR-V, IQ-V, IS-U, IR-U, IQ- have two U
threaded branch pipes cold water inlet (with a blue ring and hot water outlet (with a red : for a ) a
ring and models -H, IR-H, IQ-H, IF-V, IF-H, IF-U, ID- -H, ID- are equipped with an ), IS V, ID U
additional drainage branch pipe (with a red ring, closed with a metal plug to wash out water and )
rinse the inner tank.
The EWH has on its face a thermometer (model -V, IS- and -U 30-50, IR-V, IR -IS H IS Н
and -U 80-150). Location of the control panel depends on EWH model and type: RZL, IR -5, IR
10, 15 litres - below, ID-V, ID-H, ID-U, IF-V, IF-H, IF-U, IQ-V, IQ-H, IQ-U, IS-V, IS-H, IS-U,
IR-V, IR-H, IR- on the face side. U –
4.2. Mounted on the removable flange are: a tubular electric heater (TEHE) and sensors of
thermostat and thermoswitch. The TEHE serves to heat water and is controlled by a thermostat,
which provides continuous adjustment of temperature up to +75°C. Thermostat automatically
maintains a water temperature at the level set by the user. Temperature control knob is located on
the mechanical control panel. Models with electronic controls have touch control (Fig. 5). a
The thermoswitch serves for protection of the EWH against overheating and disconnects the
TEHE from the mains when a water temperature exceeds +95°C (Fig.4).
Model IR (5-15 litres) contains a pilot lamp to indicate the heater’s heating mode. The
thermoswitch in model -15 litres is under the top cover. IR (5 )
In models for 30-150 litres, the EWH operating mode is indicated by illumination lamps
of power selection keys these lamps are illuminated when water is heated and go out when the :
temperature of hot water preset on the thermostat is reached. In models with electronic control
by version 1, indication is effected by control lamp LI (Fig. 5) it comes on when a preset –
temperature is reached. In models with electronic control by version 2, indication is effected by a
heat indicator (Fig. 6 where the moving luminous points display the heating and are constantly )
illuminated when a preset temperature is reached.
Specyfikacje produktu
Marka: | Cointra |
Kategoria: | Kotły i bojlery |
Model: | Thermex IF |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Cointra Thermex IF, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kotły i bojlery Cointra
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
Instrukcje Kotły i bojlery
- Kotły i bojlery Tesy
- Kotły i bojlery Electrolux
- Kotły i bojlery AEG
- Kotły i bojlery Teka
- Kotły i bojlery Gorenje
- Kotły i bojlery LERAN
- Kotły i bojlery Philips
- Kotły i bojlery Morco
- Kotły i bojlery Dometic
- Kotły i bojlery Bosch
- Kotły i bojlery Whirlpool
- Kotły i bojlery Ferroli
- Kotły i bojlery Midea
- Kotły i bojlery Hisense
- Kotły i bojlery Infiniton
- Kotły i bojlery Panasonic
- Kotły i bojlery Rinnai
- Kotły i bojlery GE
- Kotły i bojlery Taurus
- Kotły i bojlery Orbegozo
- Kotły i bojlery Siemens
- Kotły i bojlery Haier
- Kotły i bojlery Jocel
- Kotły i bojlery Remeha
- Kotły i bojlery Truma
- Kotły i bojlery CATA
- Kotły i bojlery Hotpoint
- Kotły i bojlery Ariston Thermo
- Kotły i bojlery Intergas
- Kotły i bojlery Daikin
- Kotły i bojlery Kospel
- Kotły i bojlery Buderus
- Kotły i bojlery Corbero
- Kotły i bojlery Viessmann
- Kotły i bojlery Fagor
- Kotły i bojlery Vaillant
- Kotły i bojlery Eta
- Kotły i bojlery HTW
- Kotły i bojlery Dimplex
- Kotły i bojlery Baxi
- Kotły i bojlery Arçelik
- Kotły i bojlery Worcester
- Kotły i bojlery Atag
- Kotły i bojlery Rommer
- Kotły i bojlery Inventum
- Kotły i bojlery SVAN
- Kotły i bojlery Solac
- Kotły i bojlery Mora
- Kotły i bojlery VOX
- Kotły i bojlery Junkers
- Kotły i bojlery ACV
- Kotły i bojlery Aspes
- Kotły i bojlery Hitachi
- Kotły i bojlery Respekta
- Kotły i bojlery Technika
- Kotły i bojlery Quantum
- Kotły i bojlery Kelvinator
- Kotły i bojlery Sencor
- Kotły i bojlery Kunft
- Kotły i bojlery De Dietrich
- Kotły i bojlery Nefit
- Kotły i bojlery A.O. Smith
- Kotły i bojlery Stiebel Eltron
- Kotły i bojlery Elco
- Kotły i bojlery Masterwatt
- Kotły i bojlery Nibe
- Kotły i bojlery Elba
- Kotły i bojlery Buffalo
- Kotły i bojlery TTulpe
- Kotły i bojlery Atlantic
- Kotły i bojlery Plieger
- Kotły i bojlery Bulex
- Kotły i bojlery AWB
- Kotły i bojlery Quooker
- Kotły i bojlery OSO
- Kotły i bojlery La Nordica
- Kotły i bojlery Clage
- Kotły i bojlery Noveen
- Kotły i bojlery Joven
- Kotły i bojlery Daalderop
- Kotły i bojlery Fakir
- Kotły i bojlery Eccotemp
- Kotły i bojlery Biasi
- Kotły i bojlery Thermor
- Kotły i bojlery Sentry
- Kotły i bojlery Burco
- Kotły i bojlery Khind
- Kotły i bojlery LEMET
- Kotły i bojlery Duwaco
- Kotły i bojlery IQE
- Kotły i bojlery Wahlbach
- Kotły i bojlery Ygnis
- Kotły i bojlery Dux
- Kotły i bojlery Intellihot
- Kotły i bojlery Airthereal
- Kotły i bojlery Thermoflow
- Kotły i bojlery IStore
- Kotły i bojlery Apricus
- Kotły i bojlery Aquamarin
- Kotły i bojlery Sime
- Kotły i bojlery Hydrotherm
- Kotły i bojlery Amtrol
- Kotły i bojlery Neopower
- Kotły i bojlery Gleamous
- Kotły i bojlery AquaMAX
- Kotły i bojlery My-PV
- Kotły i bojlery EvoHeat
- Kotły i bojlery Rheem
- Kotły i bojlery Solahart
- Kotły i bojlery ENEFT
- Kotły i bojlery Imarflex
- Kotły i bojlery MicroHeat
- Kotły i bojlery Noritz
Najnowsze instrukcje dla Kotły i bojlery
14 Października 2024
13 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024