~,cobra®
HARDWIRE
KIT
INSTALLATION
GUIDE
WARNING:
Cobra
is
not
responsible
for
damages
to
the
vehicle
or
any
connected
products
or
accessories.
Working
with
your
vehicle's
power
system
can
be
dangerous
to
both
you
and
your
vehicle.
Cobra
recommends
professional
automotive
installation
to
avoid
damage
.
This
Vehicle
Hardwire
Kit
connects
your
Micro
USB
powered
.
device
directly
to
your
fuse
box,
freeing
up
your
12V
accessory
port
and
eliminating
clutter
on
your
dash
board.
This
Hardwire
Kit
should
work
with
any
Micro
USB
powered
device,
but
is
designed
and
tested
specifically
for
Micro
USB
powered
Radar
Detectors
and
Dash
Cams
from
Cobra.
Note:
Fuse
box
locations,
fuse
types,
and
interior
designs
vary
greatly
by
vehicle.
This
guide
is
intended
to
outline
basic
steps
for
installation
but
the
process
may
differ
depending
on
your
car's
make
and
model.
Installation
Instructions:
1.
Position
your
device
in
its
desired
location
on
the
windshield,
ensuring
that
it
does
not
obstruct
your
view
of
the
road
ahead.
Consult
your
vehicle's
manual
to
locate
your
fuse
panel.
Run
the
hardwire
kit
from
your
device,
up
and
around
the
windshield,
and
to
your
fuse
box.
Generally
you'll
want
to
position
the
hardwire
kit
so
that
excess
cable
can
be
coiled
near
the
fuse
box
side.
Note:
The
DC
Converter
Box
is
not
designed
to
withstand
the
harsh
environment
under
the
hood
of
your
vehicle
and
should
not
be
installed
there.
2.
You
need
to
decide
whether
you
want
your
device
wired
to
a
switched
or
un-switched
fuse
.
Switched
circuits
only
have
power
when
the
vehicle
is
ON.
Un-switched
circuits
always
have
power.
©2020
Co
bra
Ele
ct
ro
n
ics
Co
rp
.
Ver
s
ion
A
Prin
te
d
in
China 1
DIRECT
WRAPPING
1.
Make
sure
your
vehicle
is
off
and
the
key
is
not
in
the
ignition.
Choose
your
desired
fuse.
You
can
verify
if it
is
switched
or
un-
switched
using
a
voltmeter.
Pull
the
fuse
,
wrap
exposed
copper
part
of
the
red
(
+)
wire
around
the
fuse
tooth
,
and
re-insert
the
fuse.
2.
Locate
a
ground
point
near
the
fuse
box
.
There
is
usually
either
an
obviously
labeled
ground
point
or
a
nut/bolt
that
connects
directly
into
the
car
frame.
3.
Loosen
the
nut,
wrap
the
exposed
copper
part
of
the
black(-)
wire
around
the
bolt,
and
tighten
the
nut.
4.
Plug
your
device
into
the
hardwire
kit
and
ensure
that
it
powers
up
and
shuts
down
according
to
your
expectations.
If
so
,
you
are
ready
to
clean
up
your
installation
.
Cover
any
exposed
copper
with
electrical
tape,
secure
excess
wire
using
zip
ties
,
and
tuck
away
all
visible
wire
inside
the
headliner
.
USING
FUSE
TAPS
{sold
separately)
1.
Make
sure
your
vehicle
is
off
and
the
key
is
not
in
the
ignition.
Choose
your
desired
fuse.
You
can
verify
if it
is
switched
or
un-switched
using
a
voltmeter.
2.
Determine
the
fuse
tap
cable
required
for
connection
to
your
fuse
box.
Where
in
doubt
refer
to
the
vehicle
owner
's
manual.
3.
Place
the
vehicle
fuse
in
the
fuse
tap
cable.
4.
Locate
the
input
cable
and
connect
the
fuse
tap
cable
to
hardwire
kit
and
crimp
as
needed.
Ensure
connection
is
secure
.
5.
Insert
the
fuse
tap
into
the
fuse
box
and
tuck
away
any
excess
input
cable
behind
the
fuse
box.
6.
Locate
a
ground
point
near
the
fuse
box.
There
is
usually
either
an
obviously
labeled
ground
point
or
a
nut/bolt
that
connects
directly
into
the
car
frame
.
7.
Plug
your
device
into
the
hardwire
kit
and
ensure
that
it
powers
up
and
shuts
down
according
to
your
expectations.
If
so
,
you
are
ready
to
clean
up
your
installation.
Cover
any
exposed
copper
with
electrical
tape
,
secure
excess
wire
using
zip
ties
,
and
tuck
away
all
visible
wire
inside
the
headliner.
2
FCC
STATEMENT:
This
device
complies
with
Part
15
of
the
FCC
Rules
.
Operation
is
subject
to
the
following
two
conditions
:
(1)
This
device
may
not
cause
harmful
interference,
and
(2)
This
device
must
accept
any
interference
received
,
including
interference
that
may
cause
undesired
operation
.
WARNING:
Changes
or
modifications
not
expressly
approved
by
the
party
responsible
for
compliance
could
void
the
user
's
authority
to
operate
the
equipment.
NOTE:
This
equipment
has
been
tested
and
found
to
comply
with
the
limits
for
a
Class
B
digital
device
,
pursuant
to
Part
15
of
the
FCC
Rules.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
interference
in
a
residential
installation.
This
equipment
generates
uses
and
can
radiate
radio
frequency
energy
and
,
if
not
installed
and
used
in
accordance
with
the
instructions
,
may
cause
harmful
interference
to
radio
communications
.
However,
there
is
no
guarantee
that
interference
will
not
occur
in
a
particular
installation.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception
,
which
can
be
determined
by
turning
the
equipment
off
and
on
,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
or
more
of
the
following
measures
:
Reorient
or
relocate
the
receiving
antenna.
Increase
the
separation
between
the
equipment
and
receiver
.
Connect
the
equipment
into
an
outlet
on
a
circuit
different
from
that
to
which
the
receiver
is
connected
.
Consult
the
dealer
or
an
experienced
radio/TV
technician
for
help.
Cobra
Electronics
Corporation
is
a
trademark
of
Cobra
Electronics
Corporation
,
USA.
This
device
complies
with
RSS-31
O
of
Industry
Canada
.
Operation
is
subject
to
the
condition
that
this
device
does
not
cause
harmful
interference
.
CAN
ICES-3B/NMB-3B.
TRADEMARK
ACKNOWLEDGMENT
Cobra
,
and
the
snake
design
,
are
proprietary
trademarks
of
Cobra
Electronics
Corporation
,
USA.
Other
trademarks
and
trade
names
are
those
of
their
respective
owners
.
Cobra
Electronics
Corporation
is
a
trademark
of
Cobra
Electronics
Corporation
,
USA.
3

Specyfikacje produktu

Marka: Cobra
Kategoria: detektor
Model: CA-MICROUSB-003
Kolor produktu: Black,Red
Regulowany termostat: Tak
Typ kontroli: obrotowy
Częstotliwość wejściowa AC: 50 Hz
Napięcie wejściowe AC: 230 V
Wysokość produktu: 125 mm
Szerokość produktu: 260 mm
Głębokość produktu: 265 mm
Model: Wentylator elektryczny ogrzewacza pomieszczeń
Zabezpieczenie przed przegrzaniem: Tak
Moc grzewcza: 2500 W
Moc grzewcza (min): 1250 W
Opcje rozmieszczania: Desk,Floor,Table
Liczba poziomów zasilania: 2
Odpowiedni dla: Wewnętrzna
Lampka kontrolna: Tak
Uchwyt(y): Tak
Letnia wentylacja: Tak

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Cobra CA-MICROUSB-003, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje detektor Cobra

Instrukcje detektor

Najnowsze instrukcje dla detektor

K40

K40 Platinum200 Expert Instrukcja

9 Października 2024
K40

K40 Platinum360 Expert Instrukcja

9 Października 2024
K40

K40 RL200di Instrukcja

9 Października 2024
Noyafa

Noyafa NF-820 Instrukcja

8 Października 2024
STI

STI BIO-7505 Instrukcja

8 Października 2024
Soler & Palau

Soler & Palau CPTA Instrukcja

8 Października 2024
ORNO

ORNO OR-DC-633 Instrukcja

8 Października 2024
STI

STI -8201-W Instrukcja

8 Października 2024
STI

STI -9623 Instrukcja

8 Października 2024
STI

STI -9620 Instrukcja

8 Października 2024