Instrukcja obsługi Casio Edifice EF-558D-2A
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Casio Edifice EF-558D-2A (1 stron) w kategorii zegarek. Ta instrukcja była pomocna dla 53 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/1
1
Operation Guide 5177
MA1005-EA
Your watch may differ somewhat from the one shown in the illustration. •
7+8
DayStopwatch second hand
Crown
(Normal position)
First click
(Day, day of week setting)
Second click
(Time setting)
Day of week
Second hand
Minute hand
Stopwatch minute handHour hand
Stopwatch hour hand
To set the time
When the second hand is at 12 o’clock, pull out the crown to the second click 1.
to stop it.
Set the hands by rotating the crown. Move the minute hand four or five minutes 2.
past the setting you want, and then back them up to the setting.
Push the crown back in on a time signal to resume timekeeping.3.
To set the day and day of the week
Avoid setting the day and day of the week between 9:00 p.m. and 6:00 a.m. The •
day and day of the week may not change in the following day if you do.
Pull out the crown to the first click.1.
Set the day by rotating the crown counterclockwise.2.
Set the day of the week by rotating the crown clockwise.3.
Push the crown back in to its normal position.4.
Using the Stopwatch
The stopwatch lets you measure elapsed time up to 4 hours, 59 minutes,
59 seconds.
The illustration shows a time of 2 hours, 20 minutes, 40 seconds. •
Do not try to perform stopwatch operations while the crown is pulled out either •
to the first or second click. If you try to press a button, you might accidentally
cause the crown to rotate and change the current time or day setting.
When an elapsed time measurement reaches five hours, the stopwatch hour •
hand will stop but the stopwatch minute and second hands will continue to
move.
To measure elapsed time
Press 1. to start the stopwatch.A
Press 2. to stop the stopwatch.A
You can resume the measurement operation by pressing •A again.
Press 3. to reset the stopwatch.B
Adjusting the Stopwatch Hands Position
Use of the stopwatch can cause the starting positions of the stopwatch hour
hand, minute hand and second hand to become misaligned. Use the following
procedures to check hand alignment and to adjust the positions of the hands so
they point to 12 o’clock when the stopwatch is reset.
To adjust the positions of the stopwatch hands
Press 1. B to reset the stopwatch, and check the alignment of the stopwatch
hour hand, minute hand and second hand.
Pull out the crown to the second click.2.
Press 3. to move the stopwatch second hand forward until it points to A
12 o’clock.
If the stopwatch minute hand is aligned correctly, proceed to step 5. If the 4.
stopwatch hour hand and stopwatch minute hand are also misaligned, press B
so the stopwatch hour hand and the stopwatch minute hand jump to ).0 (60
After making the adjustments you want, push the crown back in to its normal 5.
position.
Note that pulling the crown out also stops the timekeeping second hand. After •
performing the above procedure, you should also adjust the timekeeping setting.
For a watch with an elapsed time bezel ■
Rotate the elapsed time bezel to align the mark with the
minute hand.
After certain amount of time elapsed, read the graduation on
the elapsed time bezel which the minute hand points to.
The elapsed time is indicated.
Elapsed time bezel
Some water resistant models are equipped with a screw •
lock crown.
With such models, you must unscrew the crown in the •
direction noted in the illustration to loosen it before you can
pull it out. Do not pull too forcibly on such crowns.
Also note that such watches are not water resistant while •
their crowns are loosened. Be sure to screw the crowns
back in as far as they will go after making any setting.
Specifications
Accuracy at normal temperature: ± 20 seconds a month
Display: 3 analog hands (timekeeping hour and minutes, stopwatch seconds),
3 dials (timekeeping seconds, stopwatch hours and minutes), day, day of the
week
Stopwatch function: Measuring capacity: 4:59 59 /Measuring unit: 1 second' "
Measuring modes: Elapsed time
Battery: One silver oxide battery (Type: SR927W)
Approximately 5 years on type SR927W (assuming one stopwatch operation 60 min./day)
Specyfikacje produktu
Marka: | Casio |
Kategoria: | zegarek |
Model: | Edifice EF-558D-2A |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Casio Edifice EF-558D-2A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje zegarek Casio
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
8 Czerwca 2024
Instrukcje zegarek
- zegarek Braun
- zegarek Festina
- zegarek Citizen
- zegarek Spin Master
- zegarek Auriol
- zegarek Skmei
- zegarek Jaguar
- zegarek Seiko
- zegarek Renkforce
- zegarek Skagen
- zegarek Michael Kors
- zegarek Pulsar
- zegarek Tommy Hilfiger
- zegarek Lorus
- zegarek Invicta
- zegarek Ferrari
- zegarek Tissot
- zegarek Omega
- zegarek Breitling
- zegarek Timex
- zegarek Bering
- zegarek Grand Seiko
Najnowsze instrukcje dla zegarek
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024