Instrukcja obsługi Avigilon Presence Detector (APD) Sensor

Avigilon detektor ruchu Presence Detector (APD) Sensor

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Avigilon Presence Detector (APD) Sensor (6 stron) w kategorii detektor ruchu. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/6
InstallationGuide
Avigilon Presence Detector (APD) Sensor
with Ceiling or Wall Mount Adapters
APD-S1-D and APD-MT-WALL1 (optional)
Table of Contents
Overview 1
Device Attached to the Ceiling Bracket 2
Device Attached to Wall or Corner Bracket 2
LEDIndicators 3
Back of Device 3
Positioning the APD™ Device 4
Installation 8
Required Tools and Materials 8
Device Package Contents 8
Installation Steps 8
Mounting the APD Sensor With the Surface Mount Adapter 8
Installing the Device in the Mounting Adapter 9
Assigning an IP Address 10
Configuring the APD Device 11
Initializing the APD Device and Setting the Range 12
Range-Test Mode 12
Using the Range-Test Mode Step-by-Step 12
Connection Status LED Indicator 14
Removing the APDDevice from the Mounting Adapter 15
Resetting to Factory Default Settings 16
Setting the IP Address Using the ARP/Ping Method 17
Specifications 18
For More Information 20
Limited Warranty and Technical Support 21
v
Overview
The APD device uses a short-range radar sensor to detect motion in small indoor areas. It is designed to detect
the presence of people and it is capable of detecting fine motion, such as respiration. The device is used to
detect people who enter its range and linger for extended periods of time, and can detect people who are
standing still or sleeping, and then send notifications to ACC™ servers connected to the device. It detects
whether a person is present or not but cannot quantify the number of people in range. It can be used
independently when privacy is desired or linked to a camera view for video verification.
Typically, it is configured to send notifications after it has detected that:
lA person has moved into range and lingered for a specified period of time.
lThere is no longer a person in range after a specified period of time.
lA person is present.
lA person is not present.
The notifications received by the ACCserver can be used to trigger alarms using the Rules functionality in the
ACC software. These alarms can then be monitored in the ACC Client or ACCMobile applications and then
acted upon.
The configurable settings for the device allow you to specify:
lThe range for the device, which must be set so that unwanted motion is not detected, such as people
walking along a hallway on the other side of an enclosed area being monitored.
lThe dwell time for a detected object, which is the amount of time that a person or persons are detected
in range before a notification is sent out.
lThe sensitivity of the sensor to fine motion.
Configuration can be completed using the APD Web User Interface (WebUI) when the device is installed and
connected to the network. After the device is also connected to an ACC server, configuration changes can be
made using either the WebUI or the ACCClient Software. For more information, see the Web Interface User
Guide for the APD device and Avigilon Control Center Client User Guide.
The device requires two minutes to learn the environment that is in range any time that it is powered on, or after
the range is reset. During this time, its status appears as "Initializing".
While the device is learning its environment (that is, detecting and recording the normal fixed objects in range),
no people or moving objects should be present within range of the device.
Overview 1


Specyfikacje produktu

Marka: Avigilon
Kategoria: detektor ruchu
Model: Presence Detector (APD) Sensor

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Avigilon Presence Detector (APD) Sensor, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje detektor ruchu Avigilon

Instrukcje detektor ruchu

Najnowsze instrukcje dla detektor ruchu

Maxsa

Maxsa 40234 Instrukcja

9 Października 2024
Maxsa

Maxsa 43218 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-233 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-219 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-232 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-231 Instrukcja

9 Października 2024
JUNG

JUNG BTLC17181244 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182250 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17181255 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182259 Instrukcja

8 Października 2024