Digital Laser Infrared Thermometer
INSTRUCTION SHEET
APPLICATION
Use an infrared thermometer with non-contact
infrared sensor technology to target a safe,
accurate, fast, and reliable measurement.
The AvaTemp 914DGIT1000A is perfect for
measuring surface temperatures in any food
service application.
OPERATION
Turn on
Slide out the battery compartment located
under the trigger. Install the AAA batteries
and press the trigger. The thermometer is now
turned on and showing the temperature reading
automatically on the LCD display.
DIAGRAM
A. LCD Display
B. ˚C / ˚F Button
C. Lens & Laser
D. Trigger
1. Battery Power Icon
2. Scan Lock / Hold
3. Backlight Indicator
4. ˚C / ˚F
5. Current Temperature Reading
6. Maximum State
7. Maximum Temperature
HOLD
CF
CA
1
2
3
4
5
7
6
B
D
CF
Measurement
Aim with thermometer head and press the
trigger. Release the trigger (need to press the
button for at least 0.8 seconds) to show the
current temperature reading.
Turn off
The thermometer will turn off automatically
after 30 seconds without any operation.
Accessibility
˚C / ˚F button switches the display between
Celsius and Fahrenheit.
DISTANCE TO SPOT RATIO
As the distance from the thermometer to the
object increases, the spot size of the measuring
area becomes larger. For example, if D:S=12:1,
the testing distance should be 12 times the
diameter of the target object.
CAUTION
1. Do not use solvent to clean lens.
2. Do not submerge the unit in water.
3. Do not leave the unit on or near objects of
high temperature.
4. Avoid electromagnetic fields such as arc
welding machines, induction heaters, etc.
5. Thermal shock (caused by large or abrupt
ambient temperature changes): allow 30
minutes for unit to stabilize before use.
MAINTENANCE
Lens cleaning
Blow off lose particles using clean compressed air
Gently brush remaining debris away with a moist
cotton cloth.
Thermometer cleaning
Clean with a damp sponge/cloth and mild soap.
TEMPERATURE
RANGE -58 - 968 ˚F (-50 - 520˚C)
TEMPERATURE
RESOLUTION 0.2˚F (0.C)
ACCURACY ± 2%
RESPONSE TIME 1 Seconds
SPECIFICATIONS
EMISSIVITY 0.95
OPERATING
RANGE
32 - 104˚F (0–40˚C)
HUMIDITY ≤ 85%
STORAGE RANGE 14 -140˚F (-10–60˚C)
HUMIDITY ≤ 85%
POWER 2 x AAA (1.5V)
Warning!
Do not point laser directly or indirectly
(through reflective surfaces) at eye.
12"
24"
36"
1"
2"
3"

Specyfikacje produktu

Marka: AvaTemp
Kategoria: termometr
Model: 914DGIT1000A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AvaTemp 914DGIT1000A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termometr AvaTemp

Instrukcje termometr

Najnowsze instrukcje dla termometr

Auriol

Auriol H14269 Instrukcja

15 Października 2024
Medel

Medel ECOtemp Instrukcja

9 Października 2024
Medel

Medel No Contact Plus Instrukcja

9 Października 2024
Medel

Medel Flexo Instrukcja

9 Października 2024
Owon

Owon TI300 Instrukcja

8 Października 2024
Innoliving

Innoliving INMD-DMT-437 Instrukcja

8 Października 2024