Instrukcja obsługi Ashland UT56
Ashland
Pompa wodna
UT56
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Ashland UT56 (18 stron) w kategorii Pompa wodna. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/18
• Thankyouforpurchasingthispump.Takethetimeto
readtheinstructionscarefullybeforeusingthis
product.Westronglyrecommendthatyoukeepthis
instructionmanualinasafeplaceforfuturereference.
• PleaserefertoourwebsiteandtheProductsCenterfor
additionalinstallationandoperationinstructions.
• Refertothewebsiteforreplacementpartsinformation.
“Danger” indicates an
imminent hazardous situation
which, if not avoided, WILL result in death or
serious injury.
“Caution” indicates a
potentially hazardous situation
which, if not avoided, MAY result in minor or
moderate injury.
OPERATION,PERFORMANCE,
ANDSPECIFICATIONS
Submersible
Utility Pump
MARKS AND MEANING:
LIMITED WARRANTY
Thispumpiswarrantedtobefreefromdefectsinmaterialandworkmanship
andtoperformwithinapplicablespecicationsforaperiodofoneyearfrom
dateofinstallationor18monthsfromdateofmanufacture,whichevercomes
rst.Obligationunderthiswarrantyislimitedtorepairingorreplacinganypart
thereof,whichshallwithinoneyearbereturnedtouswithtransportationcharges
prepaid,andprovedtobedefective.
Theabovelimitedwarrantytakestheplaceofallotherwarranties,expressor
impliedandcorrectionofsuchdefectsbyreplacementorrepairshallconstitute
afulllmentofallobligationsunderthetermsofthewarranty,whichspecically
EXCLUDESanyincidentaldamagescausedbyorassociatedwiththisproductor
itsuse.Thewarrantydoesnotcoveranyunitwhichhasbeendamagedeitherin
transitorbymisuse,accidentornegligence.Nowarrantyorrepresentativenot
containedhereinshallbebinding.
PERFORMANCE
GPMatTotalFeetofHead Max.
Model HP 0’ 5’ 10’ 15’ 20’ Head
UT56 1/3 48 42 31 22 13 25’
UT80 1/2 52 45 36 27 16 27’
ModelUT56/80
WARNING
CAUTION
DANGER
“Warning” indicates an
imminent hazardous situation
which, if not avoided, MAY result in death or
serious injury.
1
DANGER
Beforeinstallation,readthefollowinginstructionscare-
fully.Failuretofollowinstructionandsafetyinformation
couldcauseseriousbodilyinjury,deathand/orproperty
damage.EachAshlandPumpisindividuallyfactorytested
toensureproperperformance.Closelyfollowingthese
instructionswilleliminatepotentialoperatingproblems
assuringyearsoftrouble-freeservice.
Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for
losses, injury or death resulting from failure to observe
these safety precautions, misuse, abuse or misapplica-
tion of pumps or equipment.
All returned products must
be cleaned, sanitized, or
decontaminated prior to shipment, to
ensure employees will not be exposed to
health hazards in handling said materials.
All applicable laws and regulations shall apply.
Bronze/brassfittedpumpsmay
containleadlevelshigherthancon-
sideredsafeforpotablewatersystems.Government
agencieshavedeterminedthatleadedcopperalloys
shouldnotbeusedinpotablewaterapplications.
Installation,wiring,andjunction
connectionsmustbeinaccord-
ancewiththeNationalElectricCodeandallapplicable
stateandlocalcodes.Requirementsmayvarydepend-
ingonusageandlocation.
Installationandservicingistobe
conductedbyqualiedpersonnelonly.
Rotating machinery. Amputation
or severe lacerations can
result. Keep clear of suction and
discharge openings. DO NOT insert
fingers into pump with power connected.
Alwaysweareyeprotectionwhen
workingonpumps.Donotwearloose
clothingthatmaybecomeentangledinmovingparts.
Pumpsbuildupheatand
pressureduringoperation.
Allowtimeforpumpstocoolbeforehandlingorser-
vicing.
Hazardous Voltage can shock,
burn or cause death. Thispumpis
not intendedforuseinswimmingpoolsor
waterinstallationswherehumancontactwith
pumpedfluidispossible.
Riskofelectricalshock.To
reduceriskofelectricalshock,
alwaysdisconnectpumpfrompowersource
beforehandling. Lock out power & tag.
2
WARNING
DoNotusethesepumpsinwater
over145°F.Donotexceedmanu-
facturesrecommendedmaximumperformance,asthis
couldcausethemotortooverheat.
WARNING
WARNING
WARNING
WARNING
DANGER
DANGER
DANGER
ThesepumpsareNOTtobe
installedinlocationsclassified
ashazardousinaccordancewiththe
NationalElectricCode,ANSI/NFPA70.
WARNING
Utilitypumpsoftenhandlematerials
whichcouldcauseillnessordisease.
Wearadequateprotectiveclothingwhenworkingona
usedpumporpiping.Neverenterabasinafterithas
beenused.
WARNING
Donotintroduceintoanysewer,
eitherdirectly,orthroughakitchen
wastedisposalunitortoilet:SeafoodShells,Aquarium
Gravel,CatLitter,PlasticObjects,SanitaryNapkinsor
Tampons,Diapers,Rags,DisposableWipesorCloth,
Medications,FlammableMaterial,OilorGrease,
StrongChemicals,Gasoline.
DANGER
DANGER
Donotlift,carryorhangpumpby
theelectricalcables.Damageto
theelectricalcablescancauseshock,burnsor
death.Neverhandleconnectedpowercords
withwethands.Useappropriateliftingdevice.
DANGER
Failuretopermanentlygroundthe
pump,motorandcontrolsbefore
connectingtopowercancauseshock,burns
ordeath.
DANGER
Makesureliftinghandlesaresecurely
fastenedeachtimebeforelifting.
CAUTION
• Operationagainstacloseddischargevalvewillcause
prematurebearingandsealfailureonanypump.
• Anywiringofpumpsshouldbeperformedbya
qualiedelectrician.
• Cableshouldbeprotectedatalltimestoavoid
punctures,cuts,bruises,andabrasions-inspect
frequently.
• Neverhandleconnectedpowercordswithwethands.
• Neverletcordsorplugslieinwateroutsidethesump
pit.
Submersible Utility Pumps
Model: UT56 & UT80 Series
General Safety Information
Submersible Utility Pumps
Model: UT56 & UT80 Series
Dimensions
3
6”
2”
1.25” NPT
1.6”
6.1”
8.7”
1.2”
Specyfikacje produktu
Marka: | Ashland |
Kategoria: | Pompa wodna |
Model: | UT56 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Ashland UT56, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Pompa wodna Ashland
24 Września 2024
24 Września 2024
24 Września 2024
24 Września 2024
24 Września 2024
24 Września 2024
Instrukcje Pompa wodna
- Pompa wodna LG
- Pompa wodna Yato
- Pompa wodna Parkside
- Pompa wodna Fujitsu
- Pompa wodna Waterco
- Pompa wodna Toolcraft
- Pompa wodna Hydro-Pro
- Pompa wodna Scheppach
- Pompa wodna Gardena
- Pompa wodna Einhell
- Pompa wodna Hyundai
- Pompa wodna Silverline
- Pompa wodna Fiap
- Pompa wodna Sunnydaze Decor
- Pompa wodna Garden Feelings
- Pompa wodna Intex
- Pompa wodna CMI
- Pompa wodna Daikin
- Pompa wodna Hozelock
- Pompa wodna Buderus
- Pompa wodna Viessmann
- Pompa wodna Trotec
- Pompa wodna Meec Tools
- Pompa wodna AL-KO
- Pompa wodna Danfoss
- Pompa wodna Güde
- Pompa wodna Bavaria
- Pompa wodna Eden
- Pompa wodna Mitsubishi
- Pompa wodna Dimplex
- Pompa wodna Florabest
- Pompa wodna Ferrex
- Pompa wodna Fluval
- Pompa wodna DURO PRO
- Pompa wodna Neptun
- Pompa wodna Westfalia
- Pompa wodna Hayward
- Pompa wodna Ergotools Pattfield
- Pompa wodna Remko
- Pompa wodna Eheim
- Pompa wodna Oase
- Pompa wodna Pentair
- Pompa wodna Hitachi
- Pompa wodna SereneLife
- Pompa wodna Fieldmann
- Pompa wodna Gardenline
- Pompa wodna Vonroc
- Pompa wodna Proviel
- Pompa wodna Tetra
- Pompa wodna OKAY
- Pompa wodna Metabo
- Pompa wodna WilTec
- Pompa wodna Cotech
- Pompa wodna Yellow Garden Line
- Pompa wodna Vetus
- Pompa wodna Nibe
- Pompa wodna Norsup
- Pompa wodna Tanaka
- Pompa wodna Atlantic
- Pompa wodna Flotide
- Pompa wodna Bulex
- Pompa wodna Maxicool
- Pompa wodna For_Q
- Pompa wodna Pattfield
- Pompa wodna Swim & Fun
- Pompa wodna WHALE
- Pompa wodna Truper
- Pompa wodna Coral Box
- Pompa wodna Sunforce
- Pompa wodna Pontec
- Pompa wodna T.I.P.
- Pompa wodna Plantiflor
- Pompa wodna Sthor
- Pompa wodna Little Giant
- Pompa wodna Germania
- Pompa wodna Anova
- Pompa wodna DAB
- Pompa wodna VT
- Pompa wodna Esotec
- Pompa wodna Duromax
- Pompa wodna Elpumps
- Pompa wodna Liberty Pumps
- Pompa wodna Nowax
- Pompa wodna Zoeller
- Pompa wodna GARANTIA
- Pompa wodna Reefe
- Pompa wodna Ebara
- Pompa wodna Alphacool
- Pompa wodna AquaForte
- Pompa wodna Wingart
- Pompa wodna Heissner
- Pompa wodna Maxbear
- Pompa wodna Tallas
Najnowsze instrukcje dla Pompa wodna
11 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024