Instrukcja obsługi Arnold Rak OTD 2

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Arnold Rak OTD 2 (20 stron) w kategorii termostat. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/20
57118 05/09 (DJU)
English
German
Russian
Polish
Type OTN2 / OTD2
with room or
floor sensor
ENGLISH . . . . . . . . . . . . . page 3
GERMAN . . . . . . . . . . . . . page 7
RUSSIAN . . . . . . . . . . . . . page 11
POLISH . . . . . . . . . . . . . page 15
3
Technical data
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC ±15% 50 Hz
Max.pre-fuse ........................................16A
Built-in circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-pole, 16 A
Output relay . . . . . . . . . . . . . . . . . . . . . . . .Make contact - SPST - NO
Output .................................Max.16A/3600W
Controlprinciple ...................................ON/OFF
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+0/+40°C
Difference/hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.4°C
Economy temperature . . . . . . . . . . . . . . . . . . . . . . .5°C (2-8°C OTD2)
- control voltage signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC
Frost protection temperature . . . . . . . . . . . . . . . . . . . . . .5°C absolute
- control voltage signal via rectifier diode . . . . . . . . . . . . . . .230 V AC
Rangelimits .....................................min./max.
Sensor fault protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20°C
Ambient operating temperature . . . . . . . . . . . . . . . . . . . . . . .0/+40°C
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H/84, W/84, D/40 mm
Enclosurerating ......................................IP21
The thermostat is maintenance free.
Classification
The product is a Class II appliance (with reinforced insulation) and
must be connected as follows:
Term. 1: Live (L1) 230 V ±15%, 50/60 Hz
Term. 2: Neutral (L2)
Term. 3–4: Max. load 16 A, 3600 W
MICROLINE electronic thermostat for installation in standard wall
box. The thermostat allows the required temperature to be set within
the range 0-40°C. An LED indicates whether heating is active. The
thermostat is suitable for ELKO and NORWESCO systems S-16, RS-
16 and UNI-10. An extra frame is supplied with the unit.
MICROLINE PRODUCT PROGRAMME
OTN2-1991 with floor sensor
OTN2-1999 with built-in room sensor
OTD2-1999 with built-in room sensor and external limitation sensor
CE MARKING
Applied standards
EN 61000-6-3, EN 61000-6-2, EN 60 730-1 and EN 60730-2-9.
The product may only be used if the complete installation complies
with current directives.
The thermostat must only be installed by an authorised electrician.
If the product has been damaged in any way, e.g. during transport, it
must be inspected and checked by authorised personnel before being
connected to the power supply.
The product carries a manufacturer's warranty if installed in
accordance with these instructions and applicable regulations.
Type OTN2 / OTD2 with room or floor sensor English

Specyfikacje produktu

Marka: Arnold Rak
Kategoria: termostat
Model: OTD 2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Arnold Rak OTD 2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat Arnold Rak

Instrukcje termostat

Najnowsze instrukcje dla termostat

Siemens

Siemens RDG100T Instrukcja

15 Października 2024
Junkers

Junkers TA 21E Instrukcja

14 Października 2024
Oreg

Oreg AT90E Instrukcja

9 Października 2024
Oreg

Oreg AT60E Instrukcja

9 Października 2024
Heatit

Heatit PRO Instrukcja

9 Października 2024
Heatit

Heatit MULTIREG6 Instrukcja

9 Października 2024
Avidsen

Avidsen HomeFlow W Instrukcja

9 Października 2024
ORNO

ORNO OR-SH-17701 Instrukcja

8 Października 2024
ORNO

ORNO OR-SH-17702 Instrukcja

8 Października 2024
STI

STI -9102 Instrukcja

8 Października 2024