Instrukcja obsługi Argo AEI1G42EMX
Argo
Różne sterowanie klimatem
AEI1G42EMX
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Argo AEI1G42EMX (44 stron) w kategorii Różne sterowanie klimatem. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/44
EG
I
F
D
E
P
INSTALLATION INSTRUCTIONS •
ISTRUZIONI D’INSTALLAZIONE
NOTICE D’INSTALLATION •
INSTALLATIONSANLEITUNGEN
INSTRUCCIONES DE INSTALACION •
INSTRUÇÕES DE INSTALAÇÃO
OODDHHGGIIEESS TTOOPPOOQQEETTHHSSHHSS
37.4255.082.04 02/2017
Split air conditioner system •
Condizionatore d’aria split system
Climatiseurs split •
Split-klimagerät
Acondicionador de aire de consola partida sistema split •
Aparelho de ar condicionado-Sistema Split
ΔΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΣΜΟΥ
AEI1G42EMX
AEI1G50EMX
AEI1G50BB GR
2
IMPORTANT!
Please read before installation
This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important to install or
service the system so that it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical codes.
• Pay close attention to all warning and caution notices given in
this manual.
•The unit must be supplied with a dedicated electrical line.
This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.
If necessary, get help
These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.
SPECIAL PRECAUTIONS
• During installation, connect before the refrigerant system and
then the wiring one; proceed in the reverse orden when removing
the units.
When wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLYA QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and tubing are
completed or reconnected and checked, to ensure the grounding.
• Highly dangerous electrical voltages are used in this system.
Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause
accidental injury and death.
•Ground the unit following local electrical codes.
• The Yellow/Green wire cannot be used for any connection
different from the ground connection.
• Connect all wiring tightly. Loose wiring may cause overheating
at connection points and a possible fire hazard.
• Do not allow wiring to touch the refrigerant tubing, compressor,
or any moving parts of the fan.
• Do not use multi-core cable when wiring the power supply and
control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.
When installing...
... In a ceiling or wall
Make sure the ceiling/wall is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.
... In a room
Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to walls
and floors.
... In moist or uneven locations
Use a raised concrete base to provide a solid level foundation for
the outdoor unit.
This prevents damage and abnormal vibrations.
... In area with strong winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
... In a snowy area (for heat pump-type systems)
Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.
When connecting refrigerant tubing
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare
and union tubes before connecting them; screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.
• Check carefully for leaks before starting the test run.
NOTE:
Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.
When servicing
• Turn the power OFF at the main power board before opening
the unit to check or repair electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no
metal scraps or bits of wiring have been left inside the unit being
serviced.
• Ventilate the room during the installation or testing the
refrigeration system; make sure that, after the installation, no gas
leaks are present, because this could produce toxic gas and
dangerous if in contact with flames or heat-sources.
WARNING
CAUTION
WARNING
EG
3
Installation site selection
AVOID
• Heat sources, exhaust fans.
• Direct sunlight.
• Damp, humid or uneven locations.
• To make holes in areas where electrical wiring or conduits
are located.
DO
• Choose places as cool as possible and well ventilated.
• use lug bolts or equal to bolt down the unit, reducing
vibration and noise.
Provide a solid base for outdoor unit raised from the ground
level. Fix unit to base using 4 anchor bolts.
EG
10 cm
10 cm
40 cm
SYSTEM WIRING DIAGRAM
DUAL SPLIT
MONO SPLIT
220 - 240 V ~ 50 Hz
DELAYED FUSE
Main switch for disconnection from the supply line must have a contact separation
in all poles that provides full disconnection under category III overvoltage conditions.
Specyfikacje produktu
Marka: | Argo |
Kategoria: | Różne sterowanie klimatem |
Model: | AEI1G42EMX |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Argo AEI1G42EMX, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Różne sterowanie klimatem Argo
23 Września 2024
22 Września 2024
3 Lipca 2024
Instrukcje Różne sterowanie klimatem
- Różne sterowanie klimatem AEG
- Różne sterowanie klimatem Bosch
- Różne sterowanie klimatem Gigaset
- Różne sterowanie klimatem Siemens
- Różne sterowanie klimatem Honeywell
- Różne sterowanie klimatem Buderus
- Różne sterowanie klimatem Trotec
- Różne sterowanie klimatem Danfoss
- Różne sterowanie klimatem Vaillant
- Różne sterowanie klimatem Atag
- Różne sterowanie klimatem Remko
- Różne sterowanie klimatem Oregon Scientific
- Różne sterowanie klimatem Inventum
- Różne sterowanie klimatem Junkers
- Różne sterowanie klimatem ACV
- Różne sterowanie klimatem Elektrobock
- Różne sterowanie klimatem EasyMaxx
- Różne sterowanie klimatem Müller
- Różne sterowanie klimatem Nefit
- Różne sterowanie klimatem A.O. Smith
- Różne sterowanie klimatem Stiebel Eltron
- Różne sterowanie klimatem Elco
- Różne sterowanie klimatem SMA
- Różne sterowanie klimatem Duux
- Różne sterowanie klimatem AWB
- Różne sterowanie klimatem Xavax
- Różne sterowanie klimatem Gira
- Różne sterowanie klimatem Vasco
- Różne sterowanie klimatem Brink
- Różne sterowanie klimatem Sungevity
- Różne sterowanie klimatem Skytech
- Różne sterowanie klimatem Riello
- Różne sterowanie klimatem MCZ
- Różne sterowanie klimatem Kaysun
- Różne sterowanie klimatem Frigicoll
- Różne sterowanie klimatem Renusol
- Różne sterowanie klimatem Progenion
- Różne sterowanie klimatem Technea
- Różne sterowanie klimatem Plugwise
- Różne sterowanie klimatem HRSolar
- Różne sterowanie klimatem DGFlow
- Różne sterowanie klimatem Premix
Najnowsze instrukcje dla Różne sterowanie klimatem
5 Października 2024
28 Września 2024
28 Września 2024
28 Września 2024
27 Września 2024
27 Września 2024
27 Września 2024
27 Września 2024
26 Września 2024
26 Września 2024