READ ANDSAVE THESEINSTURCTIONS
2009 AntariLighting&EffectsLtd.
X-30WIRELESSCONTROL MODULE
USERMANUAL
BEDIENUNGSANLEITUNG
UserManual
AntariX-30WirelessControlModule
Congratulationsonthepurchaseofyournew
A X-30ntari WirelessControlModule
UserManual 01
Thank you for choosing the Antari X-30. The transmitter and the
receiving unit serve for wireless control of Antari X-310, X-510, X-515, and X-530
fog machines. The system operates with the fixed UHF frequency 433.920 MHz. The
transmission range is approx. 50 m and depends on the local conditions.
The system is designed for indoor use only. Never
remove the serial barcode from the devices as this would make the guarantee void.
wireless control module
REV3
The transmitter
operates with a 12 V battery type 23A.
-Introduction
This product is in accordance with the R&TTE directive (Radio and Telecommunication
Technical Equipment) of the European Union and falls into equipment Class 1. In all EU
member countries, the operation of this wireless system is generally approved by the
national telecom regulatory authority. The system is license-free. In some countries
outside the EU, the operation of this wireless system may needs to be approved by the
national telecoms regulatory authority.
-Approval
Keep this device dry.
For indoor use only. Not designed for outdoor use.
Ideal operating temperature is between 0° and 40° Celsius.
No user serviceable parts inside. Refer to your Antari dealer or other authorized service
personnel.
For adult use only.
Never use aggressive cleansing agents or chemicals for cleaning.
If the remote control is not used for a longer period, please remove the battery. Dispose of
used batteries properly to save the environment.
Damage, caused by manual modifications on the device are not subject to warranty. If the
device is used for other purposes than originally intended, or if it is not correctly operated
or not repaired, the product may suffer damages and the guarantee becomes void.
-SafetyInstructions
X-30
This wireless module consists of a transmitter equipped with two buttons for fog on and off
and a receiving unit with a 2-meter line, a 5-pin XLR connector and an LCD panel
displaying all operation statuses of the fog machine. The interface allows the operator to
customize fog machine functions by adjusting the fogging duration, interval, and volume
as well as the heater and the DMX and RF address. There are six buttons on the control
board. All current operating parameters are automatically stored in non-volatile memory,
allowing the machine to be powered down without losing function settings.
Screw the supplied antenna to the receiving unit. Connect the receiving unit to the
corresponding input jack on your fog machine. The jack has a latching. To remove the plug,
press the lever. Fix the receiving unit to the fog machine with the fixation screws. After
switching on, the display shortly indicates the fog machine starts with
the warm-up process and the display indicates Warming Up . While the unit is warming
up, fog output will not be possible yet. Program the necessary menu settings with the
control panel of the receiving unit. Once the warm up process is completed, fog output will
be possible. The display indicates Ready to Fog .
»Antari X-30«. Then
» «
-
» «
Use the button FUNCTION to enter the menu. Press the button FUNCTION so many times
until the desired menu item is shown in the display. Then press the button ENTER
[VOLUME] to enter the menu item. Use the buttons UP and DOWN to adjust values.
Confirm your settings with the button ENTER [VOLUME] or exit the menu item with the
button ESC [TIMER]. Never wait for more than 5 seconds to press the next button,
otherwise the setting procedure will be stopped.
-Configuration of the buttons
-Receivingunit
TRANSMITTER RECEIVINGUNIT
Blue(on)
Red(off)
ControlLED
Clip
Antenna
LCDscreen
Connectioncable
Functionbuttons
Fixationscrews
1.
Volume
Timer
DMX
Heater
RF Addr.
Interval
Volume
Duration
2.UP andDOWN
3. TIMER/ESC
4.VOLUME/ENTER
5.MANUAL/ON/OFF
TIMER
VOLUME
MANUAL
FUNCTION
VOLUME
ESC ENTER ON / OFF
TIMER MANUAL
-SetupandOperation
UserManual 02
X-30
DIP switches


Specyfikacje produktu

Marka: Antari
Kategoria: Maszyna efektów
Model: X-30 MK3

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Antari X-30 MK3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Maszyna efektów Antari

Antari

Antari F-7X Instrukcja

8 Października 2024
Antari

Antari S-120 Instrukcja

28 Września 2024
Antari

Antari MB-55 Instrukcja

20 Września 2024
Antari

Antari Z-1500 MK2 Instrukcja

19 Września 2024
Antari

Antari Z-9 Instrukcja

17 Września 2024
Antari

Antari DNG-250 Instrukcja

16 Września 2024
Antari

Antari F-80 Instrukcja

16 Września 2024
Antari

Antari Z-3000 MK2 Instrukcja

16 Września 2024
Antari

Antari M-10 Instrukcja

15 Września 2024
Antari

Antari HCR-1 Instrukcja

14 Września 2024

Instrukcje Maszyna efektów

Najnowsze instrukcje dla Maszyna efektów

Velleman

Velleman vdl660rl Instrukcja

10 Października 2024
Valcom

Valcom V-5580041A Instrukcja

8 Października 2024
Magmatic

Magmatic PMDMX1 Instrukcja

8 Października 2024
Magmatic

Magmatic CRISP Instrukcja

8 Października 2024
Magmatic

Magmatic CRISP MAX Instrukcja

8 Października 2024
Magmatic

Magmatic SIDEWINDER Instrukcja

8 Października 2024
Magmatic

Magmatic JAVELIN Instrukcja

8 Października 2024
BeamZ

BeamZ BLAZE3500 Instrukcja

8 Października 2024