Instrukcja obsługi AMX MXD-2000XL-PAN-NC

AMX Niesklasyfikowane MXD-2000XL-PAN-NC

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla AMX MXD-2000XL-PAN-NC (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
QUICK START GUIDE
MXD-2000XL-PAN 20.3" Modero X® Series Wall Mount Touch Panel
Overview
The MXD-2000XL-PAN 20.3" Modero X Series ® Panoramic Wall Mount Touch Panels feature a
beautiful, panoramic capacitive multi-touch screen that provides users access to multiple
applications with minimal navigation. It is hardware-ready for support of Near Field
Communication™ (NFC) Technology to allow integration with NFC capable personal devices.
The panoramic design offers the ability to perform multiple functions simultaneously. The
MXD-2000XL-PAN is available in Portrait and Landscape layouts:
Product Specif ications
Note: The MXD-2000XL-PAN-P-NC (FG5968-33) and MXD-2000XL-PAN-L-NC (FG5968-34) No
Comm touch panels do not have camera, microphone, or NFC capability. These otherwise have
all of the functionality of the MXD-2000XL-PAN panels.
MXD-2000XL-PAN Installation
For more detailed installation instructions including important notes on thermal
concerns with Rack and Wall installations, refer to the X-Series Touch Panels
MXD/T-2000-XL-PAN & MXD/T-1900 -PAN Instruction Manual (available to view/
download from www.amx.com).
Detailed specifications drawings for the MXD-2000XL-PAN are available to download
from www.amx.com.
The MXD-2000XL-PAN may be installed directly into a solid surface environment, using either
solid surface screws or the included locking tabs for different mounting options. Once
installed, the panel is contained within a clear outer housing known as the Backbox. The
Backbox is removed to install it into a wall, or when using the optional Rough-In Box
accessory (FG039-15).
Note: For typical mounting surfaces, such as drywall, use the locking tabs as the primary
method for securing the Backbox to the surface. For thin walls or solid surfaces, use mounting
screws (not included).
Installing the MXD-2000XL-PAN Into a Wall
The MXD-2000XL-PAN comes with a clear plastic Backbox (FIG. 2) designed to attach the
panel to most standard wall materials. This Backbox has four locking tabs (2 on top, 2 on
bottom) to help lock the Backbox to the wall. These locking tabs are only extended AFTER the
Backbox is inserted into the wall.
When installing the Backbox, make sure that the assembly is in the correct position and
in the correct place. Once the locking tabs are extended and locked into place, removing
the Backbox may be difficult without having access to the back of the wall or causing
damage to the wall.
In order to ensure a stable installation of the MXD-2000XL-PAN, the thickness of the
wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches
(2.22cm). The mounting surface should also be smooth and flat.
The Backbox also has four slots for accepting the temporary mounting posts mounted
on the back of the device.
Installing the Backbox
Since the cutout for the Backbox is off-center from the edges of the touch panel, use the
included Installation Template (68-5968-01) to ensure proper placement. The template is
marked on one side with directions for both landscape and portrait installations to ensure that
the touch panel and Backbox are properly aligned.
WARNING: Using the Installation template to select the final placement of the Backbox is highly
recommended. The outside edges of the template are the same dimensions as the touch panel,
which allows you to troubleshoot possible conflicts with wall edges, doors, and other potential
obstacles.
1. Prepare the area by removing any screws or nails from the drywall before beginning the
cutout process.
2. After ensuring proper placement, cut out the mounting surface for the Backbox, using
the (included) Installation Template as a guide.
CAUTION: Making sure that the actual cutout opening is slightly smaller than the provided
dimensions is highly recommended. This provides a margin of error if the opening needs to
be expanded. Too little wall material removed is always better than too much.
3. Thread the incoming power and Ethernet wiring from their terminal locations through
the surface opening (see FIG. 4 on reverse). Leave enough slack in the wiring to
accommodate any re-positioning of the panel.
Portrait MXD-2000XL-PAN-P FG5968-05
Landscape MXD-2000XL-PAN-L FG5968-11
FIG. 1 MXD-2000XL-PAN-P/L (PORTRAIT AND LANDSCAPE)
MXD-2000XL-PAN SPECIF ICATIONS
Dimensions (HWD) Landscape: 9 1/2" x 20 3/8" x 11/16" (242mm x 519mm x 19mm)
Portrait: 20 3/8" x 9 1/2" x 11/16" (519mm x 242mm x 19mm)
Weight 9.1 lbs (4.13 Kg)
Power
Consumption
Full-On: 32W (13.5V , 2.4A)
Standby: 3.10 W (13.5V , 0.27A)
Start-Up Inrush Current: 4.0A for 80 μsec
External Power
Supply Required
Requires one of these AMX power sources (not included):
PSR4.4 Power Supply, 4.5A, 3.5 mm Phoenix with Retention Screws
(FG423-46)
PSN4.4 Power Supply, 4.5A, 3.5 mm Phoenix, 13.5V (discontinued)
(FG423-45)
MXA-MPL Modero X Series Multi Preview Live (FG5968-10)
MXA-MP Modero X Series Multi Preview (FG5968-20)
Certifications UL 60950-1
FCC Part 15 Class B
C-Tick CISPR 22 Class B
CE EN 55022, EN 55024 and EN 60950-1
IEC 60950-1
• IC
• IEC/EN-60950
RoHS/WEEE compliant
Environmental Temperature (Operating): 32°F to 104°F (0°C to 40°C)
Temperature (Storage): 4°F to 140°F (-20°C to 60°C)
Humidity (Operating): 20% to 85% RH
Humidity (Storage): 5% to 85% RH
Power ("Heat") Dissipation:
On: 109.2 BTU/hr
Standby: 10.6 BTU/hr
Included
Accessories
Locking 2-pin Phoenix mate (41-0002-SA)
MXA-USB-C, USB Port Cover Kit (FG5968-18)
MXA-CLK, Modero X Series Cleaning Kit (FG5968-16)
Installation Template 20.3" (68-5968-01)
Sleep ButtonNFC Sensor
Sleep
NFC
Button
Sensor
MXD-2000XL-PAN-P
MXD-2000XL-PAN-L
FIG. 2 MXD-2000XL-PAN BACKBOX
FIG. 3 MXD-2000XL-PAN (LANDSCAPE)
FIG. 4 MXD-2000XL-PAN BACKBOX INSTALLATION (LANDSCAPE)
Locking Tabs
Locking Tabs
Temporary Mounting Posts
Temporary Mounting Posts
Backbox
Backbox knockouts (X8) Locking tabs (X4)
8X Knock Outs
Remove For Cable
Routing As Needed
Mounting screws
placement (optional)
Wall
4X Installation Clamp
for Wall Thickness
.37 [12.01] to .98 [25.0]
Cables Routed to
Wall Opening
© 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are
registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks
of their respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-5968-05 REV: J
Last Revised: 6/22/2015
4. Remove any knockouts as needed on either long dimension of the Backbox to facilitate
incoming wiring and pull the wiring through the resultant holes.
5. Push the Backbox into the wall opening. Insure that the locking tabs lie flush against the
Backbox.
6. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the
box until snug. Apply enough pressure to the screw head to keep the box flush with the
wall: this ensures that the locking tabs will tighten up against the inside of the wall.
7. For additional strength, #4 mounting screws (not included) may be secured through the
mounting holes located at the left and right sides of the panel (FIG. 4). In order to
prevent damage to the touch panel, make sure that these are flush with the Backbox.
8. Insert each connector into its corresponding location along the back of the device.
9. Test the incoming wiring by attaching the panel connections to their terminal locations
and applying power. Verify that the panel is receiving power and functioning properly to
prevent repetition of the installation.
Remove power before continuing with the installation.
Note: Do not disconnect the cables from the touch panel. The panel must be installed with
the cables attached before being inserted into the drywall.
Note: Configurations that use the limited access USB port on the side of the connector
box may require a right angle mating connector (not included).
10. Insert the four temporary mounting posts of the panel into the openings on the Backbox
and slide the panel onto the Backbox. This will temporarily hold the panel during the rest
of the installation (FIG. 5).
WARNING: When installing the panel, do NOT press on or near the center of the panel. Too
much stress at the center may damage the touch screen surface. When installing the
panel, pressure should be applied toward the ends of the panel ONLY.
11. Use the six provided screws, three at each end, to secure the touch panel to the Backbox
(FIG. 5). Use only the provided screws, as other screws may damage the touch panel.
12. Snap the side covers onto each end of the touch panel.
13. Reconnect the terminal Ethernet and USB to their respective locations on either the
Ethernet port or NetLinx Master.
Panel Connectors and Wiring
Connectors are located on the underside of the MXD-2000XL-PAN. The Micro-USB port is used
for camera video output. A second, limited access USB port is accessible on the back side of
this cover.
Wiring Guidelines
The MXD-2000XL-PAN uses a 13.5V -compliant power supply to provide power to the
panel via the 2-pin 3.5 mm captive wire PWR connector. Use the previously provided power
requirement information to determine the power draw. The incoming PWR and GND wires from
the power supply must be connected to the corresponding locations within the PWR
connector.
Note: Apply power to the panel only after installation is complete.
Note: Connecting power to the MXD-2000XL-PAN should be done using the included 2-pin
3.5mm captive wire connector included with the device. This connector uses retaining screws
(instead of the pins on each side of standard captive wire connectors); using excessive force to
insert a standard captive wire connector may damage the device.
Wiring a Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 13.5V -compliant power supply, the
incoming PWR and GND wires from the external source must be connected to their
corresponding locations on the connector (FIG. 6). The connector uses locking screws to
insure a connection to the device, so make sure to insert and tighten the screws before
applying power.
1. Insert the PWR and GND wires into the terminal end of the 2-pin 3.5 mm captive wire
connector cable. Match the wiring locations of the +/- on both the power supply and the
terminal connector.
2. Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing
so may strip the threads and damage the connector.
3. Verify the connection of the 2-pin 3.5 mm captive wire connector to the external
13.5V -compliant power supply and apply power.
Powering On/Off X Series Panels
X Series touch panels may be powered on by touching and holding the Sleep button. To power
off the panel, press and hold the Sleep button, and select Power Off.
Conf iguration and Programming
X Series touch panels are equipped with a Settings menu that provides the ability to configure
various features on the panels. To access the Settings menu, press and hold the Sleep button,
and select Settings.
Note: Information on the Settings menu, panel conf iguration, and programming is provided in
the Modero X Series Programming Guide, available at www.amx.com.
Setting the Panel’s Device Number and Device Name
1. In the Settings menu, select NetLinx. This opens a password keypad.
2. Enter the panel password into the keypad (the default is ) and select 1988 OK to access
the NetLinx page.
3. Press Device Number to open the NetLinx editing window.
4. Enter a unique Device Number assignment for the panel and press OK.
5. Enter a unique Device Name assignment for the panel and press OK.
Conf iguring the Panel’s IP Address
These steps configure the panel to communicate with a network; it is still necessary to
connect to the NetLinx Master (see Connecting to a NetLinx Master below).
Network Communication via DHCP
1. In the Ethernet page, press DHCP/Static field to open the DHCP/Static window. Note
that DHCP is the default setting.
2. Select Host Name, enter the new host name
3. Press OK to save changes.
Network Communication via Static Address
1. In the Ethernet page, press DHCP/Static to open the DHCP/Static window.
2. Select Static to open the Static IP window.
3. Press any field to open a keypad or keyboard (depending on the field), and enter the
appropriate network address information.
4. Press OK to save your changes and return to the Ethernet page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the NetLinx Master:
1. In the NetLinx page, press Mode to choose the connection mode (URL, Listen or Auto):
2. If password security is enabled on the target Master, enter the Username and Password:
a. Select Username to open the NetLinx window.
b. Enter the Username and Password required by the Master.
c. Press OK to save changes and return to the NetLinx page.
Related Software and Additional Documentation (at www.amx.com)
Programming the Modero X Series touch panels requires the use of the latest versions of
NetLinx Studio and TPDesign4, both available to download at www.amx.com. Refer to the
NetLinx Studio and TPDesign4 online help for information.
For additional information on the MXD-2000XL-PAN, refer to the X-Series Touch
Panels MXD/T-2000-XL-PAN & MXD/T-1900 -PAN Instruction Manual .
For detailed information on the Settings menu as well programming information and
instructions on upgrading firmware, refer to the Modero X Series Programming Guide.
FIG. 5 MXD-2000XL-PAN INSTALLATION (LANDSCAPE)
Wall
Side cover
4X Mounting posts
6X 4-40 X 1/4" LONG FLAT HEAD
TORQUE TO 5±.2 IN LBS
4X Mounting post openings
Side
cover
FIG. 6 NETLINX POWER CONNECTOR WIRING DIAGRAM
CONNECTION MODES
Mode Description Procedures
URL The device connects to the
target Master’s IP address via a
TCP connection.
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port Number, and
Username/Password (if required by the Master).
3) Press OK to save changes.
Listen This mode allows the panel to
“listen” for the Master’s
communication signals.
Note that in this mode, the
System Number and Master
IP/URL fields are read-only.
1) Select Listen in the Mode menu.
2) Confirm the panel’s IP address is on the Master’s
URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name (set on the Ethernet page), can be
used to locate the panel on the Master (particularly
useful for DHCP connections where the IP address can
change).
Auto Use this mode when both the
panel and the NetLinx Master
are on the same Subnet.
1) Select Auto in the Mode menu.
2) Enter the System Number and Username and
Password (if applicable).
3) Press OK to save changes.
PWR +
GND -
To the Touch Panel Power Supply


Specyfikacje produktu

Marka: AMX
Kategoria: Niesklasyfikowane
Model: MXD-2000XL-PAN-NC

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AMX MXD-2000XL-PAN-NC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane AMX

AMX

AMX HPX-MSP-7-SL Instrukcja

8 Października 2024
AMX

AMX HPX-MSP-10-SL Instrukcja

8 Października 2024
AMX

AMX MXD-2000XL-PAN-NC Instrukcja

2 Października 2024
AMX

AMX CB-MSA-43 Instrukcja

2 Października 2024
AMX

AMX PSR2.5 Instrukcja

2 Października 2024
AMX

AMX MSA-MMK2-10 Instrukcja

2 Października 2024
AMX

AMX VARIA-150 Instrukcja

2 Października 2024
AMX

AMX VARIA-ACS-150A Instrukcja

2 Października 2024
AMX

AMX CB-MXP-07-F Instrukcja

2 Października 2024
AMX

AMX MSA-MMK-43 Instrukcja

2 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024