Use the panel installation guide to verify proper system setup.
The RE619 Home Disaster is an integrated environmental
sensor that detects ood and extreme temperature
conditions.
Features
Titanium probes for unmatched corrosion immunity
Detects ood, freeze, and heat conditions
Secure encrypted wireless transmissions
5-year warranty
Enroll by placing the panel into wireless enrollment mode,
and then sending an enrollment signal from the sensor.
Alternatively, the sensor can be enrolled by scanning its
bar code using the Connect+ Installer App or by entering
its 8-character serial number on the interactive service
provider’s web portal. NOTE, freeze and heat inputs must
be enabled as additional zones using the installer app or
the interactive service provider’s web portal.
Install by placing the remote ood probe in the location
requiring ood or leak detection. If desired, the ood
probe can be screwed to the oor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the ood probe wires to the
sensor’s terminal blocks.
Detects water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
Heat alarms when over 100°F (38°C)
Heat restores when under 97°F (36°C)
Freeze alarms when under 45°F (7°C)
Freeze restores when over 48°F (9°C)
RE619 Home Disaster
Connect+ Encrypted
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting
Screw
Holes
Wire
Entry
Hole
Sending an Enrollment Signal
Remove the battery tab and remove the cover
to trip the tamper
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE301
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE301
WARRANTY
Alula will replace products that are defective in their rst ve (5)
years.
TRADEMARKS
Alula and Connect+ are trademarks owned by Alula Holdings, LLC.
Panasonic is a registered trademark owned by Panasonic
Corporation.
Pro Tips
Both titanium probes must be in the same puddle for the sensor to detect water.
A second probe can be added for additional protection in another location. Do not
install more than two probes.
The ood probe can be mounted in a sump tank at the desired height to provide pump
failure notication.
47-0021-08 • REV E • 2019-02-07
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.25 x 1.40 x 1.05 inches (8.3 x 3.6 x 2.7 cm)
1.90 ounces (54 grams)
#4 or #6 screws (not provided)
Environmental
Operating Temperature
Maximum Humidity
32 to 120 °F (0 to 49 °C)
85% non-condensing relative humidity
Sensor Specications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
433.92 MHz
One Panasonic® CR123A
8 to 10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Flood, Freeze, Heat, Tamper, Low Battery, Supervision
+/- 2°C
Certication
RE619 FCC, IC
Specications subject to change without notice.
Specications
00
00


Specyfikacje produktu

Marka: Alula
Kategoria: Niesklasyfikowane
Model: RE619

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Alula RE619, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Alula

Alula

Alula RE118 Instrukcja

1 Października 2024
Alula

Alula RE605 Instrukcja

1 Października 2024
Alula

Alula RE619 Instrukcja

1 Października 2024
Alula

Alula RE305 Instrukcja

1 Października 2024
Alula

Alula RE219 Instrukcja

1 Października 2024
Alula

Alula RE318 Instrukcja

1 Października 2024
Alula

Alula RE105 Instrukcja

1 Października 2024
Alula

Alula RE205 Instrukcja

1 Października 2024
Alula

Alula RE218 Instrukcja

1 Października 2024
Alula

Alula RE119 Instrukcja

1 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024