Instrukcja obsługi AFX Lake LAKS0513LAJUDBK

AFX Ulga Lake LAKS0513LAJUDBK

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla AFX Lake LAKS0513LAJUDBK (2 stron) w kategorii Ulga. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
LED door Luminaires In
Surface Mount Bi-level MS
120 27- 7VAC 60Hz/
Page of 6 R01 2 8061 94
Model #: APS, EVNS, HVNS,
LBTS, LAKS,
View shown for reference
only. Individual models
may vary.
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing thisxture. Failure to comply with these instructions could result in potentially fatal electric shock and/or
property damage.
is recommended that a qualied electrician perform all the wiring. This xture must be wired in accordance with all national and local electrical codes. It
Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
This xture is designed for use in a 120- VAC / 60Hz circuit. This xture is compatible with a TRIAC (forward-phase or leading-edge) / ELV (reverse-phase or trailing-edge) and 0-10V dimming 277
circuit.
Make sure that the power source conforms to the requirements of the xture. (See labels on the xture housing).
To reduce the risk of electrical shock, and to assure proper operation, thisxture must be adequately grounded. To accomplish proper grounding, there must be a s rate ground wire (green) epa
contact between thisxture and the ground connection of your main power supply panel.
This xture is intended to be used for general indoor lighting in dry or damp locations.
Disclaimer
Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Can an ICES-005 (B) / NMB-005 (B). These limits are designed to provide reasonable adi
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modications to this xture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Assembly Instructions
Step 1 Preparing for installation
A. at the fuse or circuit breaker box before installing or servicing any part of this Disconnect electrical power
xture.
B. Carefully remove the xture and hardware kit from the carton.
C. Remove components from the hardware kit.
D. Install 1/8- protrude above the 27 threaded stem (3) to mounting bracket (1), allow approximately 0.75” to
bracket then use hex nut (4) to secure it.
E. Install mounting bracket (1) to the 3/0 or 4/0 junction box (not included) using two screws #8- (2) to secure 32
it.
Wiring All wiring must take place inside junction box (not included)
Caution: Make sure power is o at the fuse or circuit breaker box. Check power es for damage or scrapes. wir
If power supply wires are within three inches of the D driver, use wire suitable for at least 90°C (194°F). LE
Note: Most dwellings built before 1985 have supply wire rated to 60°C. Consult a qualied electrician to
ensure correct branch circuit conductor before installing.
Step 2 Wiring xture
A. Make all wire connections to appropr te wire. Secure with wire nuts (provided).ia
B. Connect the green wire from the xture to the supply power source ground wire.
C. Connect the white wire from the xture to the white (N) wire from the supply power For non-dimming.
source. Connect the black xture wire to the black (L) wire from the supply power sourc Pink and purple e.
wires are not to be used and must be individually capped to prevent shorting.
D. Connect the white wire from the xtur to co esponding neutral (N) wire in accordance For TRIAC dimming.e rr
with the dimmer manufacturer instructions. Connect the black wire from the xture to the corresponding
control line (L) wire in accordance with the dimmer manufacturer instructi . Pink and purple wires are not to ons
be used and must be individually capped to prevent shorting.
E. Connect the pink wire from the xture to the dimmer source gray or pink wire. Connect For 0-10V dimming.
the purple wire from the xture to the dimmer source purple wire. Connect the white wire from the xture to the neutral (N)
wire from the dimm supply source per dimmer wiring instructions. Connect the black wire from the xture to the control er
line (L) wire from the dimmer supply power source per dimmer wiring instructions.
F. ll on each wire lead to ke sure connections are secure. Make certain no bare wires are exposed outside of wire Do not mix wires. Pu ma
connectors. Tuck all connections neatly into the junction box.
Step 3 Color changing temperature adjustment, CCT (if desired)
A. Adjust CCT switch inside the xture according to the desired color temperature of 2700K, 3000K, 3500K,
4000K, or 5000K as shown below. Note: Fixture is preset to 3000K from factory.
Step 4 Mounting
A. Insta xture (5 to the mounting bracket using barrel nut (6 secure i ll ) ) to t.
Step 5 Diuser
A. Insta xture (5 to the mounting bracket using barrel n ll )
Step 6 Restore power at the fuse or circuit breaker box
Step 7 -Level Motion Sensor Operation Bi
A. The factory will set dip switch to 100% detection, seconds Hold Time, Disable Daylight Sensor, 0 seconds Standby Period and 30% dim Note: To select other settings follow dip switch chart 5 .
below.
2700K
•3000K
•3500K
•4000K
•5000K
LED door Luminaires In
Surface Mount Bi-level MS
120 27- 7VAC 60Hz/
Page of 2 2 8061694 R0
Model #: APS, EVNS, HVNS,
LBTS, LAKS,
Limited Factory Warranty
AFX Inc. hereby warrants that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years
from date of purchase. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due to improper
installation, misuse, mishandling or damage incurred in transit.
Dip Switch Settings:
Detection
Range
1
I
ON
100%
II
-
50%
Hold Time
2
I
ON
5sec
II
ON
90sec
III
-
5min
IV
-
15min
Daylight
Sensor
4
I
ON
Disable
II
ON
50Lux
III
-
20Lux
IV
-
5Lux
Standby
dimming
level
6
Brightness
I
ON
0Sec
II
ON
10Sec
III
-
10Min
IV
-
+
Standby
Percentage
8
I
ON
10%
II
-
30%
Initialization
Switch function/three-stage dimming function: the light will be turned on
100% brightness by the initial energizing sensor, and will be turned o
after 10 seconds. During initialization, no external motion sensing
signal will be detected.
Two-phase dimming function: the light will turn on 100% brightness in
the initial energizing sensor, and turn to low brightness 10 seconds
later (the brightness set by stand-by dim level). During initialization, no
external motion sensing signal will be detected.
Factory setting
Detection Area: 100%, Hold Time: 5 Seconds, Daylight Sensor:
Disable, Stand-by Period: 0S , Dimming brightness preset function: ec
3 0%
Application notice
1. The sensor should be installed by a professional electrician. Please
turn o the power before installing, wiring, changing the setting of the
DIP switch.
2. The sensor which installed in the plastic and glass lampshade will
reduce the sensitivity. For every 0.120 increase in thickness, the
sensitivity will be reduced by 20%.
3. The light sensitivity threshold is in a sunny environment, no shadow
and ambient light diuse reection. Ambient lux level could be dierent
in dierent environment, weather, climate, time-of day and season.
4. The parameters of the sensor may need to be recongured in dierent
installation environments.
5. This sensor is for indoor use only. It will aect the waterproof eect for
outdoor use. Wind, rain, and moving objects around will cause false
triggering.
6. The distance between any inductive sensors should be greater than
9.8ft.
7. Do not place the sensor close to high-density objects such as metal,
glass, concrete walls, etc, false triggering could happen. When the
sensor is installed in metal lamp, metal reective surface, or a narrow a
enclosed environment, the microwave will be reected repeatedly and
cause false triggering. Please reduce the sensitivity or contact the
manufacturer for technical support.
8. Please ensure that there are no moving signals around the sensor,
such as fan,DC motor, sewer pipe, air outlet, etc., the sensor may
generate false trigger.
9. The data on detection pattern is typical value tested without any lighting
xture in factory, the detection range could be aected by moving
speed, installation height, motion object and dierent environment.
10. Due to continuous improvement, the contents of this instruction could
be changed without prior notice.


Specyfikacje produktu

Marka: AFX
Kategoria: Ulga
Model: Lake LAKS0513LAJUDBK

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AFX Lake LAKS0513LAJUDBK, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ulga AFX

Instrukcje Ulga

Najnowsze instrukcje dla Ulga