Instrukcja obsługi Zephyr ZRE-E42BBSGG
Zephyr
Okap wyciągowy
ZRE-E42BBSGG
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Zephyr ZRE-E42BBSGG (72 stron) w kategorii Okap wyciągowy. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/72

WWW.ZEPHYRONLINE.COM
MAR22.0101
Anzio Island
ZAZ-M90DS
ZAZ-E42DS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
Luce Island
ZLC-M90CS
ZLC-E42CS
Roma Island
ZRM-E36FS
ZRM-E42FS
Ravenna Island
ZRE-M90BBSGG
ZRE-E42BBSGG
Ai
rflow Control Technolo
gy
TM
C

2Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide

3
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information 4-6 ............................................................................
Types of Safety Warnings 4 ...................................................................
General Safety 4-5 ..................................................................................
Operation 6 ...........................................................................................
Electrical Requirements 6 ......................................................................
Federal Communication Commission Interface Statement 6 .................
List of Materials 7 ...................................................................................
Installation Instructions 8-19 .....................................................................
Ducting Calculation Sheet 8 ..................................................................
Mounting Height, Clearance, & Ducting 9 .............................................
Ducting Options 10 .................................................................................
ZAZ Hood Specifications 11 .....................................................................
ZLC Hood Specifications 12 ....................................................................
ZRM Hood Specifications 13 ....................................................................
ZRE Hood Specifications 14 .....................................................................
Electrical Supply 15 .................................................................................
Cable Lock 15 .........................................................................................
Mounting the Hood 16-18 ..........................................................................
Ductless Recirculation 19 ........................................................................
Features & Controls 20-23 .........................................................................
ICON Touch Controls 20-21 .......................................................................
Optional Remote Control 22-23 .................................................................
Maintenance 23-24 ...................................................................................
Hood & Filter Cleaning 23-24 .....................................................................
LumiLight LED 24 ...................................................................................
ACT™ Conversion 25-26 ............................................................................
Airflow Control Technology (ACT™) ................................................... 25
Enabling ACT™ .................................................................................. 26
Wiring Diagram ................................................................................27-31
Troubleshooting............................................................................... 32-33
List of Parts & Accessories 34 ..................................................................
Limited Warranty 35 ...............................................................................
Product Registration 36 ...........................................................................

4Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER WARNING CAUTION” “ ” or “ ”
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
General Safety
WARNING
Warning means that failure to heed this safety statement
may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.

5
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn o the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do
not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

6Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Safety Information
Operation
►Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
►The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and
the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
►Observe all governing codes and ordinances.
►It is the customer’s responsibility to be aware of these below:
►To contact a qualified electrical installer.
►To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
►If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
►Do not ground to a gas pipe.
►Check with a qualified electrician if you are not sure the range hood is properly grounded.
►Do not have a fuse in the neutral or ground circuit.
►This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
►A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
►This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
►This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
►Reorient or relocate the receiving antenna.
►Increase the separation between the equipment and receiver.
►Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
►Consult the dealer or an experienced radio/TV technician for help.
READ AND SAVE THESE INSTRUCTIONS

7
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Extension duct covers
Optional recirculating kit
Optional remote control
(3) Wire Nuts (4) ø12 OD / ø5
ID Washers
(4) M4 x 1”
wood screws
(4) 3/16 x 1/4” flat-head
machine screws
(1) Hardware package
(1) 6” round damper (pre-installed)
HARDWARE PACKAGE CONTENTS
(2) Top Duct Covers
(1) Top Support Frame
(2) Bottom Duct Covers
(1) Bottom Support Frame
(1) Hood Body
(4) LumiLight LED
(2) Mesh Filters
(ZAZ-E42 & ZRM-E42 x 3)
(1) M4 x 12
safety screw
A
B
Front of Hood
CL
/
Cut-Out Shaded Area
(1) Paper ceiling template
(20) M4 x 8 pan-head
machine screws
(ZLC x 8)
(2) Lateral support brackets
(ZLC ONLY)
(1) Square support bracket
(ZAZ ONLY)
(4) 3/16 x1/4 pan-head
machine scews
(ZRE only)

8Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Duct pieces Total
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) = Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column 1 =
Duct pieces Total
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) = Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0 elbow
23 Ft. x ( ) = Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 900
elbow
15 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 450
elbow
9 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 900
flat elbow
24 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) = Ft.
Ft. x ( ) = Ft.
156”, 7“, 8”
Round
in-line
damper
Ducting Calculation Sheet

9
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum of 6” round duct must be used to maintain
maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could
restrict air flow by up to 50%.
Also use calculation (on page 8) to compute total available
duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions
and turns. If long duct run is required, increase duct size.
If turns or transitions are required; install as far away from
hood duct output and as far apart, between the two as
possible.
Minimum mount height between range top to hood bottom
should be no less than 24”. Maximum mount height should
be no higher than 34”.
It is important to install the hood at the proper mounting
height. Hoods mounted too low could result in heat
damage and fire hazard; while hoods mounted too high
will be hard to reach and will lose its performance and
eciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood mounting
height above range.
For shipment and installation damages:
►Please fully inspect unit for damage before installation.
►If the unit is damaged in shipment, return the unit to the
store in which it was bought for repair or replacement.
►If the unit is damaged by the customer, repair or
replacement is the responsibility of the customer.
►If the unit is damaged by the installer (if other than
the customer), repair of replacement must be made by
arrangement between customer and installer.
A
B
C
D
E
F
ZAZ ZLC ZRM
Standard Duct Cover
Extension Duct Cover
A
B
C
D
E
F
ZAZ ZLC ZRM
28”
31”
39”
88” (7’ 4”)
80”
150” (12’ 6”)
29”
89” (7’ 5”)
47”
51”
80”
150” (12’ 6”)
107” (8’ 11”)
111” (9’ 3”)
36”
50”
96” (8’ 0”)
120” (10’)
47”
51”
80”
107” (8’ 11”)
111” (9’ 3”)
150” (12’ 6”)
A : Minimum Ducted Hood Height
B : Minimum Recirculating Hood Height
C : Maximum Hood Height
D : Minimum Ducted Ceiling Height
E : Minimum Recirculating Ceiling Height
F : Maximum Ceiling Height
min. A
min. B
max. C
36”
24” min.
34” max.
min. D
min. E
max. F
31-1/2”
91-
1/2
” (7’ 7-
1/2
”)
32-1/2”
46-1/2”
92-
1/2
” (7’ 8-
1/2
”)
116-
1/2
” (9’ 8-
1/2
”)
91” (7’ 7”)
109” (9’ 1”)
50-1/2”
50-1/2”
110-
1/2
” (9’ 2-
1/2
”)
110-
1/2
” (9’ 2-
1/2
”)
ZRE
ZRE
28-1/2”
39”
78”
148” (12’ 4”)
109” (9’ 1”)
48-1/2”
48-1/2”
108-
1/2
” (9’
1/2
”)
109-
1/2
” (9’
1/2
”)
28-1/2”
88-
1/2
” (7’ 4-
1/2
”)
88-
1/2
” (7’ 4-
1/2
”)

10 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Ducting Options
►Use single wall rigid metal ductwork only.
►Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Roof Pitch w/
Flashing & Cap
Sot or crawl space
(blower
housing)
ductless
recirculating
side wall cap
w/ gravity damper

11
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
ZAZ Hood Specications
FRONT SIDE
TOP TOP SUPPORT FRAME
(top view)
C/L
8- ”1/8
7-9/16”
3- 9/16”
13/16”
4- ”3/16
8-1/4”
STANDARD
min. ducted - 31- 1/2”
min. recirc. - 36”
max. - 50”
Z1C-00AZ
min. ducted - 47”
min. recirc. - 51”
max. - 80”
10- ”5/8
25- 9/16”
1- ”3/16
11”
35- 7/16 15/16”, 41- ”
9-7/16”16-9/16”
5- ”1/4
5-
15/16
”
3- ”1/2
AC In
1- ”1/4
C/L
C/L
1-7/8”
5- ”5/16

12 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
ZLC Hood Specications
FRONT SIDE
TOP of HOOD TOP SUPPORT FRAME
(top view)
FRONT
11”
35-7/16”, 41-7/8”
STANDARD
min. ducted - 29”
min. recirc. - 32- 1/2”
max. - 46- 1/2”
Z1C-00LC
min. ducted - 47”
min. recirc. - 51”
max. - 80”
6”
C/L
C/L
9-7/16”12- ”3/8
2- 1/16”
10- ”5/8
25- 9/16”
3-7/16”
2- ”1/2
1- ”1/4
7-9/16”
7-13/16”
8- 1/8”
6- ”3/4

13
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
ZRM Hood Specications
3”
STANDARD
min. ducted - 28”
min. recirc. - 31”
max. - 39”
Z1C-01RM EXTENSION
min. ducted - 50-
1/2
”
min. recirc. - 50-
1/2
”
max. - 80”
12”
AC-IN
CL
FRONT SIDE
TOP
14”
9-11/16”
11-3/16 ”
35- 7/8 ”, 41-7/8 ” 26- 7/8 ”
12-7/16”
4-3/16 ”
11”
ø 6”
9-7/16 ”
2-3/8 ”

14 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
ZRE Hood Specications
FRONT SIDE
TOP TOP SUPPORT FRAME
( )
10-3/8 ”
23- 15/16”
35- 3/16”25- 9/16”
24-
1/2
”
3-
9/16
”
10-7/8 ”
2- 3/4 ”
11-
5/8
”
4-
3/8
”
(top of electrical box)
13-3/4 ”
5/16”
C/L
6”
8”
8-
3/4
”
8- 1/4”
3-3/4 ”
4- 3/16 ”
5/8”
elec. k/o
STANDARD
min. ducted - 28- 1/2”
min. recirc. - 28- 1/2”
max. - 38”
Z1C-01REBS EXTENSION
min. ducted - 48- 1/2”
min. recirc. - 48- 1/2”
max. - 78”

15
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualied person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable ckLo
FIG. A

16 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Mounting the Hood
At least two installers are required due to the weight
and size of the hood.
CAUTION
1. Determine mounting location on ceiling and
temporarily tape paper template (included with
the hood) to the ceiling. Cut out internal shaded
area of template to allow the ducting and electrical
to pass through. If necessary, add wood blocking
(min. 2” x 4”) to ceiling joists located behind the
drywall to reinforce the mounting location*. (FIG.
B1). Secure (2) M6 x 1” wood screws to points A and
B of the paper template (FIG. C). Do not completely
tighten screws, leave approximately 1/4” exposed.
2. Remove screws securing top and bottom support
frames together. Adjust support frame to
accommodate the desired hood height and re-
assemble the frame using the previously removed
screws (2 screws for each support frame arm). (FIG.
B3).
FIG. B
1
2
Ceiling Joists
Wood Blocking
Top Support Frame
Support Frame Arm
Bottom Support Frame
Hood Body
3
Mounting Screws
(pre-installed)
4
*Hood is intended to be mounted to a nished ceiling.
FIG. C
A
B
Cut-Out Shaded Area
FRONT
FIG. D
Top Support Frame
Side
Front

17
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
3. Lift support frame assembly up to the ceiling
making sure the word “front” on the top support
frame faces the front of the hood where the
controls will be located. (FIG. D) The key holes
on the top support frame should cover the wood
screws previously installed in the ceiling. Slide
support frame towards narrow end of key holes to
lock the frame in place. Install the last (2) M6 x 1”
wood screws with washers into the two remaining
corners of the top support frame to secure it to the
ceiling. Tighten all screws.
4. ZRE ONLY: Remove aluminum mesh lters from
hood. Place canopy over blower housing and
secure it to hood body using (4) 3/16 x 1/4 pan
head machine screws through lter opening. (FIG.
E)
5. Lift hood and align the (4) pre-installed mounting
screws located on top of the unit body (FIG. A4)
with the (4) key holes on the Bottom of Support
Frame. (FIG. F). Slide hood towards the narrow end
of key holes to lock into place. Hand tighten each
of the (4) screws with a screwdriver to secure hood
to Bottom Support Frame. Further secure bottom
support frame to unit body by one M4 x 12 safety
screw. (FIG. G).
6. Remove tape securing electronics mounting bracket
to hood and reposition electronics mounting
bracket. Install electrical and duct work.
7. Power up hood, verify all functions and check for
leaks around duct tape.
Mounting the Hood
FIG. E
BLOWER
HOUSING
FIG. F
Bottom Support Frame
(secures to top of blower housing)
Key Holes
front - facing controls
back
FIG. G

19
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ductless Recirculation
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood.
Fumes and exhaust from cooking are drawn and ltered by a set of optional charcoal lters. The air is
then puried and re-circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
duct work, if possible. The hood is most eective and ecient as an exhaust hood. Only when the
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard
Metal Filter set. Order according to its part number below. The standard mesh lters are intended to
capture residue from cooking, and the optional charcoal lters help to purify fumes exhausted from
cooking for recirculation.
Recirculating Kit Installation (required if no ducting is used)
For detailed installation instructions, please refer to the manual included with the recirculating kit.
The kit includes the charcoal lters, lter attachment clip, and air diverter plate.
Hood Model Recirculating Kit
Part Number
Quantity to
Order
Charcoal Filter
Replacement Part
Number
Quantity to
Order
ZAZ ZRC-02AZ 2 Z0F-C091 2
ZLC ZRC-00LC 1 Z0F-C092 1
ZRM-E36DS ZRC-02RM 2 Z0F-C002 2
ZRM-E42DS ZRC-01RM 3 Z0F-C002 3
ZRE ZRC-00RE 2 Z0F-C002 2
1. Purchase recirculating kit per the part number above. Secure air diverter plate to top support
frame. Open sides of air diverter plate should face left and right to direct air through the louver
holes located on the top duct cover. Run 6” ducting from top of hood and secure to air diverter
plate.
2. Remove mesh lters from hood. Install charcoal lters as referenced with the manual included with
recirculation kit. Reinstall mesh lters.
3. Turn on charcoal lter replace indicator on control panel. The microprocessor in the controls will
indicate the need to change the charcoal lter after 120 hours of continuous use.
DO NOT WASH CHARCOAL FILTERS. Charcoal lters may need to be changed more often depending
on cooking habits.
Specyfikacje produktu
Marka: | Zephyr |
Kategoria: | Okap wyciągowy |
Model: | ZRE-E42BBSGG |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Zephyr ZRE-E42BBSGG, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Okap wyciągowy Zephyr

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024

12 Grudnia 2024
Instrukcje Okap wyciągowy
- Okap wyciągowy Bauknecht
- Okap wyciągowy Ikea
- Okap wyciągowy Samsung
- Okap wyciągowy Tesy
- Okap wyciągowy Bertazzoni
- Okap wyciągowy Electrolux
- Okap wyciągowy DeLonghi
- Okap wyciągowy AEG
- Okap wyciągowy Balay
- Okap wyciągowy Beko
- Okap wyciągowy Teka
- Okap wyciągowy LG
- Okap wyciągowy Küppersbusch
- Okap wyciągowy Smeg
- Okap wyciągowy Gram
- Okap wyciągowy Amica
- Okap wyciągowy Gorenje
- Okap wyciągowy Etna
- Okap wyciągowy LERAN
- Okap wyciągowy Sharp
- Okap wyciągowy Cookology
- Okap wyciągowy Russell Hobbs
- Okap wyciągowy Dometic
- Okap wyciągowy Bosch
- Okap wyciągowy Candy
- Okap wyciągowy Whirlpool
- Okap wyciągowy Miele
- Okap wyciągowy Midea
- Okap wyciągowy Toolcraft
- Okap wyciągowy Lamona
- Okap wyciągowy Hisense
- Okap wyciągowy Berg
- Okap wyciągowy Infiniton
- Okap wyciągowy Panasonic
- Okap wyciągowy Baumatic
- Okap wyciągowy OK
- Okap wyciągowy Hoover
- Okap wyciągowy Tesla
- Okap wyciągowy Westinghouse
- Okap wyciągowy Maytag
- Okap wyciągowy GE
- Okap wyciągowy Orbegozo
- Okap wyciągowy Blaupunkt
- Okap wyciągowy Brandt
- Okap wyciągowy Vivax
- Okap wyciągowy Siemens
- Okap wyciągowy Grundig
- Okap wyciągowy Haier
- Okap wyciągowy KKT Kolbe
- Okap wyciągowy Cylinda
- Okap wyciągowy Jocel
- Okap wyciągowy Silverline
- Okap wyciągowy Blomberg
- Okap wyciągowy Honeywell
- Okap wyciągowy Concept
- Okap wyciągowy Fisher & Paykel
- Okap wyciągowy ECG
- Okap wyciągowy Indesit
- Okap wyciągowy Ilve
- Okap wyciągowy Viking
- Okap wyciągowy Nodor
- Okap wyciągowy CATA
- Okap wyciągowy Broan
- Okap wyciągowy Hotpoint
- Okap wyciągowy V-Zug
- Okap wyciągowy Ariston Thermo
- Okap wyciągowy Zelmer
- Okap wyciągowy PKM
- Okap wyciągowy Unox
- Okap wyciągowy Thor
- Okap wyciągowy Amana
- Okap wyciągowy Dacor
- Okap wyciągowy Hotpoint Ariston
- Okap wyciągowy Furrion
- Okap wyciągowy Bomann
- Okap wyciągowy InAlto
- Okap wyciągowy Meireles
- Okap wyciągowy Schneider
- Okap wyciągowy MPM
- Okap wyciągowy CDA
- Okap wyciągowy Sam Cook
- Okap wyciągowy Philco
- Okap wyciągowy Neff
- Okap wyciągowy Corbero
- Okap wyciągowy Zanussi
- Okap wyciągowy Thermex
- Okap wyciągowy Fagor
- Okap wyciągowy Everdure
- Okap wyciągowy Thomson
- Okap wyciągowy Ardo
- Okap wyciągowy Klarstein
- Okap wyciągowy Coyote
- Okap wyciągowy Witt
- Okap wyciągowy Wolkenstein
- Okap wyciągowy Cecotec
- Okap wyciągowy Artusi
- Okap wyciągowy KitchenAid
- Okap wyciągowy Imperial
- Okap wyciągowy Helios
- Okap wyciągowy Sôlt
- Okap wyciągowy Exquisit
- Okap wyciągowy Bartscher
- Okap wyciągowy Hestan
- Okap wyciągowy Privileg
- Okap wyciągowy Dimplex
- Okap wyciągowy Falmec
- Okap wyciągowy Arçelik
- Okap wyciągowy Hanseatic
- Okap wyciągowy Continental Edison
- Okap wyciągowy Linarie
- Okap wyciągowy Atag
- Okap wyciągowy Rosieres
- Okap wyciągowy Franke
- Okap wyciągowy Novy
- Okap wyciągowy Rommer
- Okap wyciągowy Inventum
- Okap wyciągowy SVAN
- Okap wyciągowy Euro Appliances
- Okap wyciągowy Mora
- Okap wyciągowy Caple
- Okap wyciągowy AEG-Electrolux
- Okap wyciągowy Omega
- Okap wyciągowy Comfee
- Okap wyciągowy Classique
- Okap wyciągowy Kenmore
- Okap wyciągowy Kaiser
- Okap wyciągowy VOX
- Okap wyciągowy Hiberg
- Okap wyciągowy AYA
- Okap wyciągowy Pelgrim
- Okap wyciągowy Frilec
- Okap wyciągowy Orima
- Okap wyciągowy Rex
- Okap wyciągowy Kernau
- Okap wyciągowy Aspes
- Okap wyciągowy Weller
- Okap wyciągowy Twin Eagles
- Okap wyciągowy Respekta
- Okap wyciągowy Technika
- Okap wyciągowy Seiki
- Okap wyciągowy JennAir
- Okap wyciągowy Frigidaire
- Okap wyciągowy Matrix
- Okap wyciągowy Barazza
- Okap wyciągowy Summit
- Okap wyciągowy Gemini
- Okap wyciągowy Sirius
- Okap wyciągowy Foster
- Okap wyciągowy Chef
- Okap wyciągowy Fulgor Milano
- Okap wyciągowy Kelvinator
- Okap wyciągowy Gaggenau
- Okap wyciągowy Elica
- Okap wyciągowy Asko
- Okap wyciągowy Esatto
- Okap wyciągowy Signature
- Okap wyciągowy BlueStar
- Okap wyciągowy Porter & Charles
- Okap wyciągowy Kunft
- Okap wyciągowy Robinhood
- Okap wyciągowy Becken
- Okap wyciągowy Scandomestic
- Okap wyciągowy Ignis
- Okap wyciągowy Guzzanti
- Okap wyciągowy Venmar
- Okap wyciągowy Belling
- Okap wyciągowy De Dietrich
- Okap wyciągowy ZLine
- Okap wyciągowy Constructa
- Okap wyciągowy Proline
- Okap wyciągowy Euromaid
- Okap wyciągowy BLANCO
- Okap wyciągowy Scancool
- Okap wyciągowy Thermador
- Okap wyciągowy Bestron
- Okap wyciągowy Zanker
- Okap wyciągowy Kluge
- Okap wyciągowy Acec
- Okap wyciągowy Airlux
- Okap wyciągowy ABK
- Okap wyciągowy Ariston
- Okap wyciągowy Saturn
- Okap wyciągowy Progress
- Okap wyciągowy Bellini
- Okap wyciągowy Vestel
- Okap wyciągowy Itho
- Okap wyciągowy Prima
- Okap wyciągowy Junker
- Okap wyciągowy Monogram
- Okap wyciągowy Scholtes
- Okap wyciągowy Profilo
- Okap wyciągowy Heinner
- Okap wyciągowy Juno
- Okap wyciągowy Defy
- Okap wyciągowy Nordmende
- Okap wyciągowy Rangemaster
- Okap wyciągowy Boretti
- Okap wyciągowy Eico
- Okap wyciągowy Hansa
- Okap wyciągowy Air King
- Okap wyciągowy Elba
- Okap wyciągowy Steel Cucine
- Okap wyciągowy Jenn-Air
- Okap wyciągowy Limit
- Okap wyciągowy Freggia
- Okap wyciągowy Edesa
- Okap wyciągowy Lofra
- Okap wyciągowy New World
- Okap wyciągowy Leisure
- Okap wyciągowy Glem Gas
- Okap wyciągowy Viva
- Okap wyciągowy M-System
- Okap wyciągowy German Pool
- Okap wyciągowy Falcon
- Okap wyciągowy Airforce
- Okap wyciągowy Ices
- Okap wyciągowy Mx Onda
- Okap wyciągowy Kleenmaid
- Okap wyciągowy Stoves
- Okap wyciągowy Faber
- Okap wyciągowy Eurotech
- Okap wyciągowy Wolf
- Okap wyciągowy Carrefour Home
- Okap wyciągowy Mepamsa
- Okap wyciągowy Upo
- Okap wyciągowy Belion
- Okap wyciągowy SIBIR
- Okap wyciągowy Sauter
- Okap wyciągowy Café
- Okap wyciągowy ARC
- Okap wyciągowy Lynx
- Okap wyciągowy FABER CASTELL
- Okap wyciągowy Tecnolux
- Okap wyciągowy Tisira
- Okap wyciągowy Cobal
- Okap wyciągowy Premier
- Okap wyciągowy Marynen
- Okap wyciągowy Axiair
- Okap wyciągowy La Germania
- Okap wyciągowy Gutmann
- Okap wyciągowy Roblin
- Okap wyciągowy Oranier
- Okap wyciągowy Bielmeier
- Okap wyciągowy Turbo Air
- Okap wyciągowy Schweigen
- Okap wyciągowy James
- Okap wyciągowy Apelson
- Okap wyciągowy Dominox
- Okap wyciągowy NuTone
- Okap wyciągowy Eudora
- Okap wyciągowy Steelmatic
- Okap wyciągowy Wells
- Okap wyciągowy Piccante
- Okap wyciągowy Kucht
- Okap wyciągowy Best
- Okap wyciągowy Wave
- Okap wyciągowy Halifax
- Okap wyciągowy Siku
- Okap wyciągowy Elin
- Okap wyciągowy High One
- Okap wyciągowy Whispair
- Okap wyciągowy Ciarra
- Okap wyciągowy XO
- Okap wyciągowy Adelberg
- Okap wyciągowy K&H
- Okap wyciągowy Cosmo
- Okap wyciągowy FAURE
- Okap wyciągowy Viali
- Okap wyciągowy Kobe
- Okap wyciągowy Qasair
- Okap wyciągowy Berbel
- Okap wyciągowy Samus
- Okap wyciągowy Royal Catering
- Okap wyciągowy Sedona
- Okap wyciągowy Vitrokitchen
- Okap wyciągowy Arthur Martin-Electrolux
- Okap wyciągowy Elektra Bregenz
- Okap wyciągowy CENDO
- Okap wyciągowy Pando
- Okap wyciągowy Applico
- Okap wyciągowy Airone
- Okap wyciągowy Trade-Wind
- Okap wyciągowy Mayer
- Okap wyciągowy Vent-A-Hood
- Okap wyciągowy HomeCraft
- Okap wyciągowy CEEM
- Okap wyciągowy Condor
- Okap wyciągowy Baumann
- Okap wyciągowy Pitsos
- Okap wyciągowy Windster
- Okap wyciągowy Conia
Najnowsze instrukcje dla Okap wyciągowy

17 Marca 2025

15 Marca 2025

14 Marca 2025

14 Marca 2025

11 Marca 2025

11 Marca 2025

10 Marca 2025

10 Marca 2025

10 Marca 2025

10 Marca 2025