Instrukcja obsługi Zephyr ZRE-E42BBSGG

Zephyr Okap wyciągowy ZRE-E42BBSGG

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Zephyr ZRE-E42BBSGG (72 stron) w kategorii Okap wyciągowy. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/72
WWW.ZEPHYRONLINE.COM
MAR22.0101
Anzio Island
ZAZ-M90DS
ZAZ-E42DS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
Luce Island
ZLC-M90CS
ZLC-E42CS
Roma Island
ZRM-E36FS
ZRM-E42FS
Ravenna Island
ZRE-M90BBSGG
ZRE-E42BBSGG
Ai
row Control Technolo
gy
TM
C
2Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
3
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information 4-6 ............................................................................
Types of Safety Warnings 4 ...................................................................
General Safety 4-5 ..................................................................................
Operation 6 ...........................................................................................
Electrical Requirements 6 ......................................................................
Federal Communication Commission Interface Statement 6 .................
List of Materials 7 ...................................................................................
Installation Instructions 8-19 .....................................................................
Ducting Calculation Sheet 8 ..................................................................
Mounting Height, Clearance, & Ducting 9 .............................................
Ducting Options 10 .................................................................................
ZAZ Hood Specifications 11 .....................................................................
ZLC Hood Specifications 12 ....................................................................
ZRM Hood Specifications 13 ....................................................................
ZRE Hood Specifications 14 .....................................................................
Electrical Supply 15 .................................................................................
Cable Lock 15 .........................................................................................
Mounting the Hood 16-18 ..........................................................................
Ductless Recirculation 19 ........................................................................
Features & Controls 20-23 .........................................................................
ICON Touch Controls 20-21 .......................................................................
Optional Remote Control 22-23 .................................................................
Maintenance 23-24 ...................................................................................
Hood & Filter Cleaning 23-24 .....................................................................
LumiLight LED 24 ...................................................................................
ACT™ Conversion 25-26 ............................................................................
Airflow Control Technology (ACT™) ................................................... 25
Enabling ACT.................................................................................. 26
Wiring Diagram ................................................................................27-31
Troubleshooting............................................................................... 32-33
List of Parts & Accessories 34 ..................................................................
Limited Warranty 35 ...............................................................................
Product Registration 36 ...........................................................................
4Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER WARNING CAUTION” “ ” or “
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
General Safety
WARNING
Warning means that failure to heed this safety statement
may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
5
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn o the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do
not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
6Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Safety Information
Operation
Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and
the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility to be aware of these below:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
READ AND SAVE THESE INSTRUCTIONS
7
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Extension duct covers
Optional recirculating kit
Optional remote control
(3) Wire Nuts (4) ø12 OD / ø5
ID Washers
(4) M4 x 1”
wood screws
(4) 3/16 x 1/4” flat-head
machine screws
(1) Hardware package
(1) 6” round damper (pre-installed)
HARDWARE PACKAGE CONTENTS
(2) Top Duct Covers
(1) Top Support Frame
(2) Bottom Duct Covers
(1) Bottom Support Frame
(1) Hood Body
(4) LumiLight LED
(2) Mesh Filters
(ZAZ-E42 & ZRM-E42 x 3)
(1) M4 x 12
safety screw
A
B
Front of Hood
CL
/
Cut-Out Shaded Area
(1) Paper ceiling template
(20) M4 x 8 pan-head
machine screws
(ZLC x 8)
(2) Lateral support brackets
(ZLC ONLY)
(1) Square support bracket
(ZAZ ONLY)
(4) 3/16 x1/4 pan-head
machine scews
(ZRE only)
8Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Duct pieces Total
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) = Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column 1 =
Duct pieces Total
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) = Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0 elbow
23 Ft. x ( ) = Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 900
elbow
15 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 450
elbow
9 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect. 900
flat elbow
24 Ft. x ( ) = Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) = Ft.
Ft. x ( ) = Ft.
156”, 7, 8
Round
in-line
damper
Ducting Calculation Sheet
9
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum of 6” round duct must be used to maintain
maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could
restrict air flow by up to 50%.
Also use calculation (on page 8) to compute total available
duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions
and turns. If long duct run is required, increase duct size.
If turns or transitions are required; install as far away from
hood duct output and as far apart, between the two as
possible.
Minimum mount height between range top to hood bottom
should be no less than 24”. Maximum mount height should
be no higher than 34”.
It is important to install the hood at the proper mounting
height. Hoods mounted too low could result in heat
damage and fire hazard; while hoods mounted too high
will be hard to reach and will lose its performance and
eciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood mounting
height above range.
For shipment and installation damages:
Please fully inspect unit for damage before installation.
If the unit is damaged in shipment, return the unit to the
store in which it was bought for repair or replacement.
If the unit is damaged by the customer, repair or
replacement is the responsibility of the customer.
If the unit is damaged by the installer (if other than
the customer), repair of replacement must be made by
arrangement between customer and installer.
A
B
C
D
E
F
ZAZ ZLC ZRM
Standard Duct Cover
Extension Duct Cover
A
B
C
D
E
F
ZAZ ZLC ZRM
28”
31
39”
88” (7’ 4”)
80”
150” (12’ 6”)
29”
89” (7’ 5”)
47
51
80”
150” (12’ 6”)
107” (8’ 11”)
111” (9’ 3”)
36”
50”
96” (8’ 0”)
120” (10’)
47
51
80”
107” (8’ 11”)
111” (9’ 3”)
150” (12’ 6”)
A : Minimum Ducted Hood Height
B : Minimum Recirculating Hood Height
C : Maximum Hood Height
D : Minimum Ducted Ceiling Height
E : Minimum Recirculating Ceiling Height
F : Maximum Ceiling Height
min. A
min. B
max. C
36”
24” min.
34” max.
min. D
min. E
max. F
31-1/2
91-
1/2
” (7’ 7-
1/2
”)
32-1/2
46-1/2
92-
1/2
” (7’ 8-
1/2
”)
116-
1/2
” (9’ 8-
1/2
”)
91” (7’ 7”)
109” (9’ 1”)
50-1/2
50-1/2
110-
1/2
” (9’ 2-
1/2
”)
110-
1/2
” (9’ 2-
1/2
”)
ZRE
ZRE
28-1/2
39”
78
148” (12’ 4”)
109” (9’ 1”)
48-1/2
48-1/2
108-
1/2
” (9’
1/2
”)
109-
1/2
” (9’
1/2
”)
28-1/2
88-
1/2
” (7’ 4-
1/2
”)
88-
1/2
” (7’ 4-
1/2
”)
10 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Ducting Options
Use single wall rigid metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Roof Pitch w/
Flashing & Cap
Sot or crawl space
(blower
housing)
ductless
recirculating
side wall cap
w/ gravity damper
11
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
ZAZ Hood Specications
FRONT SIDE
TOP TOP SUPPORT FRAME
(top view)
C/L
8- ”1/8
7-9/16
3- 9/16
13/16”
4- ”3/16
8-1/4”
STANDARD
min. ducted - 31- 1/2
min. recirc. - 36”
max. - 50”
Z1C-00AZ
min. ducted - 47”
min. recirc. - 51”
max. - 80”
10- ”5/8
25- 9/16
1- ”3/16
11”
35- 7/16 15/16”, 41-
9-7/1616-9/16
5- ”1/4
5-
15/16
3- ”1/2
AC In
1- ”1/4
C/L
C/L
1-7/8
5- ”5/16
12 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
ZLC Hood Specications
FRONT SIDE
TOP of HOOD TOP SUPPORT FRAME
(top view)
FRONT
11”
35-7/16”, 41-7/8
STANDARD
min. ducted - 29”
min. recirc. - 32- 1/2
max. - 46- 1/2
Z1C-00LC
min. ducted - 47”
min. recirc. - 51”
max. - 80”
6”
C/L
C/L
9-7/1612- ”3/8
2- 1/16
10- ”5/8
25- 9/16
3-7/16
2- ”1/2
1- ”1/4
7-9/16
7-13/16
8- 1/8
6- ”3/4
13
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
ZRM Hood Specications
3”
STANDARD
min. ducted - 28”
min. recirc. - 31”
max. - 39
Z1C-01RM EXTENSION
min. ducted - 50-
1/2
min. recirc. - 50-
1/2
max. - 80”
12”
AC-IN
CL
FRONT SIDE
TOP
14”
9-11/16
11-3/16
35- 7/8 ”, 41-7/8 26- 7/8
12-7/16
4-3/16
11”
ø 6”
9-7/16
2-3/8
14 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
ZRE Hood Specications
FRONT SIDE
TOP TOP SUPPORT FRAME
( )
10-3/8
23- 15/16
35- 3/1625- 9/16
24-
1/2
3-
9/16
10-7/8
2- 3/4
11-
5/8
4-
3/8
(top of electrical box)
13-3/4
5/16”
C/L
6”
8”
8-
3/4
8- 1/4
3-3/4
4- 3/16
5/8”
elec. k/o
STANDARD
min. ducted - 28- 1/2
min. recirc. - 28- 1/2
max. - 38”
Z1C-01REBS EXTENSION
min. ducted - 48- 1/2
min. recirc. - 48- 1/2
max. - 78”
15
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualied person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable ckLo
FIG. A
16 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
Mounting the Hood
At least two installers are required due to the weight
and size of the hood.
CAUTION
1. Determine mounting location on ceiling and
temporarily tape paper template (included with
the hood) to the ceiling. Cut out internal shaded
area of template to allow the ducting and electrical
to pass through. If necessary, add wood blocking
(min. 2” x 4”) to ceiling joists located behind the
drywall to reinforce the mounting location*. (FIG.
B1). Secure (2) M6 x 1” wood screws to points A and
B of the paper template (FIG. C). Do not completely
tighten screws, leave approximately 1/4” exposed.
2. Remove screws securing top and bottom support
frames together. Adjust support frame to
accommodate the desired hood height and re-
assemble the frame using the previously removed
screws (2 screws for each support frame arm). (FIG.
B3).
FIG. B
1
2
Ceiling Joists
Wood Blocking
Top Support Frame
Support Frame Arm
Bottom Support Frame
Hood Body
3
Mounting Screws
(pre-installed)
4
*Hood is intended to be mounted to a nished ceiling.
FIG. C
A
B
Cut-Out Shaded Area
FRONT
FIG. D
Top Support Frame
Side
Front
17
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
3. Lift support frame assembly up to the ceiling
making sure the word “front” on the top support
frame faces the front of the hood where the
controls will be located. (FIG. D) The key holes
on the top support frame should cover the wood
screws previously installed in the ceiling. Slide
support frame towards narrow end of key holes to
lock the frame in place. Install the last (2) M6 x 1”
wood screws with washers into the two remaining
corners of the top support frame to secure it to the
ceiling. Tighten all screws.
4. ZRE ONLY: Remove aluminum mesh lters from
hood. Place canopy over blower housing and
secure it to hood body using (4) 3/16 x 1/4 pan
head machine screws through lter opening. (FIG.
E)
5. Lift hood and align the (4) pre-installed mounting
screws located on top of the unit body (FIG. A4)
with the (4) key holes on the Bottom of Support
Frame. (FIG. F). Slide hood towards the narrow end
of key holes to lock into place. Hand tighten each
of the (4) screws with a screwdriver to secure hood
to Bottom Support Frame. Further secure bottom
support frame to unit body by one M4 x 12 safety
screw. (FIG. G).
6. Remove tape securing electronics mounting bracket
to hood and reposition electronics mounting
bracket. Install electrical and duct work.
7. Power up hood, verify all functions and check for
leaks around duct tape.
Mounting the Hood
FIG. E
BLOWER
HOUSING
FIG. F
FIG. G
18 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Installation Instructions
8. Assemble Top Duct Covers (with louver holes)
together over Top Support Frame, secure Top
Duct Covers together by magnetic strips.
NOTE: If using hood in ductless recirculating
mode, you must install the air diverter plate to
the Top Support Frame prior to assembling the
duct covers.
9. Secure Top Duct Covers to Top Support Frame
by using (4) 3/16 x 1/4 screws (2 screws for
each Top Duct Cover). (FIG. H1).
10. Assemble Bottom Duct Covers together over
Top Duct Covers and secure together by
magnetic strips. Bottom Duct Covers should
rest on top of the Hood Body.
Mounting the Hood
FIG. H
1
Top Duct Covers
Top Support Frame
Bottom Duct Covers
Bottom Support Frame
19
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ductless Recirculation
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood.
Fumes and exhaust from cooking are drawn and ltered by a set of optional charcoal lters. The air is
then puried and re-circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
duct work, if possible. The hood is most eective and ecient as an exhaust hood. Only when the
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard
Metal Filter set. Order according to its part number below. The standard mesh lters are intended to
capture residue from cooking, and the optional charcoal lters help to purify fumes exhausted from
cooking for recirculation.
Recirculating Kit Installation (required if no ducting is used)
For detailed installation instructions, please refer to the manual included with the recirculating kit.
The kit includes the charcoal lters, lter attachment clip, and air diverter plate.
Hood Model Recirculating Kit
Part Number
Quantity to
Order
Charcoal Filter
Replacement Part
Number
Quantity to
Order
ZAZ ZRC-02AZ 2 Z0F-C091 2
ZLC ZRC-00LC 1 Z0F-C092 1
ZRM-E36DS ZRC-02RM 2 Z0F-C002 2
ZRM-E42DS ZRC-01RM 3 Z0F-C002 3
ZRE ZRC-00RE 2 Z0F-C002 2
1. Purchase recirculating kit per the part number above. Secure air diverter plate to top support
frame. Open sides of air diverter plate should face left and right to direct air through the louver
holes located on the top duct cover. Run 6” ducting from top of hood and secure to air diverter
plate.
2. Remove mesh lters from hood. Install charcoal lters as referenced with the manual included with
recirculation kit. Reinstall mesh lters.
3. Turn on charcoal lter replace indicator on control panel. The microprocessor in the controls will
indicate the need to change the charcoal lter after 120 hours of continuous use.
DO NOT WASH CHARCOAL FILTERS. Charcoal lters may need to be changed more often depending
on cooking habits.
20 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Features & Controls
Lights Low/High/O
Display (speed level, delay o, lter clean/change)
Adjust 5 Speed elsLev
P er / Delay Oow
1 POWER / DELAY OFF BUTTON
Po r Button Functionwe
- Button will turn p er on and o for entire hood (fan and lights).ow
- Hood will remember the last speed and light level it was turned o at.
(Example: Press Button to turn o hood when on fan speed 4 and high lights.
Press Button again and the hood will turn back on at speed 4 and high lights
l el.)ev
Delay O Button Function
- With the fan on press and hold the Button for two seconds. The fan will change
to speed 1 and the 5 minute delay o timer will start.
+ LEDs will illuminate and slowly blink in accordance
with the time remaining until the fan and lights automatically turn o.
- Pressing Button while Delay O Function is enabled will turn the hood o and
cancel the Delay O Function.
ACT Verication
- Airo rol Technology (Aw Cont CT) allows the installer to set the maximum fan
CFM to align with local codes and regulations.
- To verify the maximum fan CFM:
- With hood o, hold the Button for two seconds. If all ve fan speed
indicators illuminate = default maximum CFM. If four fan speed indicators
illuminate = 390 maximum CFM. If 3 fan speed indicators illuminate = 290
maximum CFM.
2 SPEED SELECTION BUT NTO
Fan Speed Decrease Button
- Press this button to decrease fan speed. 5, 4, 3, 2, 1.
- If fan is On Speed 1 and this button is p ssed, fan will p er O.re ow
Fan Speed Increase Button
- Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.
- If hood is O and this button is pressed, fan will turn On Speed 1.
Act Enabled Speed Selections
- When ACT is enabled, the number of fan speeds will be duced as follore ws:
- 390 CFM = Maximum 4 speeds
- 290 CFM = Maximum 3 speeds
Lighted Glass Button
5
MODEL ZLC ONLY
ICON Touch Controls
21
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Features & Controls
3 LIGHTS BUT NTO
- Lights have two l els, w and High.ev Lo
- From o, press one time for Low. Press again for High. Pr er ligh ess again to pow ts
o.
4 DISPL INDICAY ATORS
Mesh Filter Clean Reminder (always enabled)
- After 30 hours of fan usage, the button indicator will begin to slowly blink
indicating it is time to clean the mesh lters.
- To reset: With hood o: hold the button for three seconds. All LED indicators
will blink two times conrming the 30 hour timer has been reset.
Charcoal Filter Replace Indicator (disabled by default, must be enabled if
circulating hood)re
- enable Char er Replacement minder:To coal Filt Re
- With hood o, hold button and button simultaneously for two
seconds. All LED indicators will illuminate for three seconds conrming the
Charcoal Filter Replace Reminder is enabled.
- disable Char er Replacement minder:To coal Filt Re
- With hood o, hold button and button simultaneously for two
seconds. All LED indicators will blink two times conrming the Charcoal Filter
Replace Reminder is disabled.
- After 120 hours of fan usage the button will slowly blink indicating the char
coal lters need replacment.
- To reset: With hood o, hold the button for two seconds. All LED indicators will
blink two times conrming the 120 hour timer has been reset.
5 LIGHTED GLASS BUTTON (MODEL ZLC ONLY)
- Press to cycle glass color from Whit Blue, Amber and O.e,
- Press and hold for 3 seconds to activate demo mode. While in demo mode each
color will gradually change every 10 seconds.
- Pr essing to p er o the LED lights will also p er o the lighted glasow ow s.
ICON Touch Controls
22 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Features & Controls
Optional RF Remote Control
To enable RF remote control capabilities, the remote control accessory kit is required. The part
number for the kit is RC-0002.
FCC Caution
To assure continued compliance, any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment. (Example -
use only shielded interface cables when connecting to computer or peripheral device. This device
complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. (1)
This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
Installation
To install remote control accessory kit, please follow these steps below.
1. Locate PC board box on top of blower housing.
2. Remove 2-4 screws attaching PC board cover.
3. Connect the red wiring from the remote control control board to red connector in hood PC board.
4. Adhere remote control control board near PC board box.
5. The blue antenna wire needs to be extended for optimal signal. There is no need to secure it.
Synchronization
To create a unique link between your hood and remote control please follow these steps.
1. With hood o, press and hold the Lights button on the hood until the controls illuminate and flash.
2. Press a button on the remote, and the remote control will be synchronized with the hood.
RF Remote Control Functions
Blower On / Speed Selection
Press to power on blower and cycle through all blower speeds.
Blower On / Power O
By pressing , the blowers will power on at the last speed setting. Press
again and the entire hood will power o, including lights.
Delay O
Lights On/Dim/O
Switch between light levels by pressing . Turn o the lights by cycling through
the dierent light levels.
Blower On/
Speed Selection
1
1
2
3
4
Blower On/
Power O
2
5 Min Delay O 3Lights On/Dim/O
4
By pressing , the blower and lights will enter Delay O mode. The blow
er will
change to speed 1 and a 5 minute timer will begin counting down.
23
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Features & Controls
Optional RF Remote Control
RF Remote Features
The RF remote control is equipped with a magnet on the back for easy storage. The remote may
be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. I. The
remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote
holder does not charge the RF remote.
Maximum remote control communication distance is 15 feet from the liner.
RF Remote Maintenance
Clean the remote control using non abrasive detergents.
Follow instructions below for replacing battery. Using a small flat head screwdriver, raise the cover of
the battery door (A) in order to access the battery compartment. FIG. J.
Remove the battery and replace with battery type A23 12V. Negative end of battery should face the
spring inside the remote.
Re-install battery door and recycle old battery.
FIG. I
A
-
+
FIG. J
24 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Hood & Filter Cleaning
Surface Maintenance
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub
in the direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser
detergent.
After cleaning use a non-abrasive stainless steel polish/cleaners, to polish and bu out the stainless
luster and grain. Always scrub lightly, with clean cotton cloth or micro fiber cloth and bu in the
direction of the stainless steel grain.
Cleaning Grease Filters
The grease filters installed by the factory are intended to filter out residue and grease from cooking.
They need not be replaced on a regular basis but are required to be kept clean.
Remove and clean by hand or in dishwasher using a non-phosphate detergent. Discoloration of
the grease filter may occur if using phosphate detergents, or as a result of local water conditions -
but this will not aect filter performance. This discoloration is not covered by the warranty. Spray
degreasing detergent and leave to soak if heavily soiled.
Dry grease filters and re-install before using hood.
Maintenance
25
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installing the Grease Filters (FIG. K):
1. Pull down on filter latch to release the filter tabs.
2. Pull down on front of filter to remove the grease filters.
Maintenance
FIG. K
LumiLight LED
In the unlikely event that your LumiLight LED fails, please
contact Zephyr to order replacement parts.
See the list of parts and accessories page for part numbers
and contact information.
LED Removal (FIG. L):
1. Remove grease filters.
2. Remove the side panels (if applicable) and remove the
light panel.
3. Disconnect LED light quick connector.
4. Push in the two side clips on the ends of the LED light.
5. Push LED light through the light panel opening.
Push the clip
FIG. L
26 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Hood must be disconnected from the main power prior to
performing the conversion instructions listed below. Failure to do
so could result in personal injury or damage to the product.
CAUTION
After re-positioning the jumper and powering on the hood, the
CFM cannot be changed again.
CAUTION
ACT™ Conversion
Airow Control Technology (ACT™)
Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you
to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for
expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to
one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT™ may not be
necessary for your installation. Please check your local codes for CFM restrictions.
27
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
ACT™ Conversion
Enabling ACT™
To enable ACT™:
1. Before hood installation, gain access to PC board by following the steps shown on FIG. M.
2. Change plastic jumper positioning as shown in FIG. N to set the desired maximum blower CFM.
3. Re-install PC board and continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the
hood body below the wiring diagram or in another clearly visible location.
To verify if your installer enabled ACT™:
1. With hood o, hold the power button for three seconds. If 5 LEDs illuminate = default max. If 4
LEDs illuminate = max. 390 CFM, and if 3 LEDS illuminate = max. 290 CFM.
2. When ACT™ is enabled, the number of blower speeds will be reduced. 390 CFM = max. 4 speeds
and 290 CFM = max. 3 speeds.
3. There should also be a foil label located inside the hood body near the wiring diagram that
indicates the blower CFM.
Models: ZAZ, ZLC, ZRM, ZRE
- Locate PC board box on top of blower housing.
- Remove 2 to 4 screws attaching PC board cover.
FIG. M
PC Board
1
3
5
7
2
4
6
8
Ju mp er 5- 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
Ju mp er 3- 4
Max. Blower CFM
390
Ju mp er 1- 2
Jumper Pins
Plastic
Jumper
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
Max. Blower CFM
290
FIG. N
28 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Wiring Diagram
Body
REMARKS: CONDENSER 12.5+12.5uF 250V AC FIT AC120V 60Hz
Green
Black
White
Black
White
Yellow
Yellow
Yellow
White
Yellow
Blue
Red
Brown
Grey
Green
Body
ZAZ-E42DS, ZAZ-M90DS
Wiring Diagram
Volts Hz Max. Amps
120 60 4
Motor
Red
29
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Wiring Diagram
LED LED
LED LED
ZLC-M90CS, ZLC-E42CS
Wiring Diagram
Volts Hz Max. Amps
120 60 4
REMARKS: CAPACITOR 12.5+12.5uF 250V AC FIT AC120V 60Hz
Motor
Green
Body
Red
Yellow
Blue
Brown
Grey
White
Black
White
Body
Green
Black
White
Yellow
Red
Yellow
Control PC
30 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Wiring Diagram
ZRM-E36FS, ZRM-E42FS
Wiring Diagram
Volts Hz Max. Amps
120 60 4
Motor
Green
Body
Red
Yellow
Blue
Brown
Grey
Red
White
Yellow
Yellow
Yellow
Yellow
Control
Body
Green
Black
White
REMARKS: CONDENSER 12.5+12.5uF 250V AC FIT AC120V 60Hz
31
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Wiring Diagram
ZRE-M90BBSGG
ZRE-E42BBSG
Wiring Diagram
Volts Hz Max. Amps
120 60 4
REMARKS: CONDENSER 12.5+12.5uF 250V AC FIT AC120V 60Hz
Green
Black
White
Body
Black
White
Control
Yellow
Yellow
Yellow
Yellow
White
Motor
Body
Green
Yellow
Red
Red
Blue
Brown
Grey
32 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Troubleshooting
Possible Problem Possible Cause Solutions
After installation, the
unit doesn’t work.
The power source is not turned
ON.
Make sure the circuit breaker and the
units power is ON.
The power line and the cable
locking connector is not
connecting properly.
Check the power connection with the
unit is connected properly.
The switch board or control board
is defective.
Change the switch board or control
board.
The switch board or control board
wirings are disconnected.
Make sure the wirings at the switch
board and control board are connected
properly.
Light works, but
blower is not turning.
The blower is defective, possibly
seized.
Change the blower.
The thermally protected system
detects if the blower is too hot
to operate and shuts the blower
down.
The blower will function properly after
the thermally protected system cool
down.
Damaged capacitor. Change the capacitor.
The switch board or control board
is defective.
Change defective part.
The unit is vibrating. The blower is not secured in place. Tighten the blower in place.
Damaged blower wheel. Replace the blower.
The hood is not secured in place. Check the installation of the hood.
The unit is whistling. A filter is not in the correct
position.
Adjust the filters until the whistling stops.
The duct pipe connections are not
sealed or connected properly.
Check the duct pipe connections to be
sure all connections are sealed properly.
The blower is working,
but the lights are not.
The LED light connector is
disconnected.
Connect the LED light connector.
Defective LED light. Change the LED light.
LumiLight LEDs flicker
when changing speed
levels.
N/A This is a normal operation and the hood
is working correctly.
33
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Troubleshooting
The hood is not
venting out properly.
Using the wrong size of ducting. Change the ducting to the correct size
The hood might be hanging to
high from the cook top.
Adjust the distance between the cooktop
and the bottom of the hood within 24”
to 34” range.
The wind from the opened
windows or opened doors in the
surrounding area are aecting
the ventilation of the hood.
Close all the windows and doors to
eliminate the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct
work or duct opening.
Filter is vibrating. Filter is loose. Adjust or change the filter.
RF Remote control does
not work.
Battery is dead. Replace battery with type A23 12v.
Poor communication with the hood. Remote control must be within 15 ft of hood.
RF Remote lost communication with
the hood.
Reset hood and remote by switching power
o at the circuit breaker for 5 minutes.
Place remote on counter top near the hood
and switch the circuit breaker back on.
Blue antenna wire is not extended. Extend the blue antenna wire behind the
light panel.
Possible Problem Possible Cause Solutions
35
Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Limited Warranty
Zephyr Ventilation, LLC (ref ed ein e” ts the original consumer purchaser (referred to herein err to her as “w or “us”) warran to
as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or
workmanship as fo ows: ll
Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will
provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to
manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or
replace parts before we elect to replace the Products.
One Year Limited Warranty for Labor: For one year from the date of your original purchase of the Products, we will
provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to
manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original
purchase, you are responsible for all labor costs asso t cia ed wi is anth h t warr ty.
Warranty Exclusions: This warranty covers only repair or replacement, at our option, of defective Products or parts and
does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service
required for the Products and consumable parts such as fluorescent, incandescent or hal en light bulbs, mesh and char-og
coal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident,
faulty installation or installation contrary to recommended installation instructi s, improper maintenance or repair (other on
than by us); (c) commercial or government use of the Products or use otherwise inconsistent with its intended purpose; (d)
natural wear of the finish of the Products or wear c sed by improper maintenance, use of corrosive and abrasive cl ning au ea
products, pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service
trips to your home to teach you how to use the Products; (g) damage to the Product caused by accident, fire, floods, acts s
of God; or (h) Custom installations or alterations that impact ic the Products. If you are outside our service serv eability of
area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the
travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year
from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products
must be installed by a qualified professional installer to be eligible for warranty repairs or service.
Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE
AND EXCLUSIVE REMEDY UNDER THIS WA ANTY. WE SHALL NOT BE LIABLE R INCIDENTAL, RR FO
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CO ECTION WITH THE USE OR NN
PERFORMANCE OF THE PRODUCTS. T W TIES IN THE PRECEDING E HE EXPRESS ARRAN SECTION AR
EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRE SS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL
OTHER EXPRESS W TIES FOR THE PRO TS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES ARRAN DUC
IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. To the extent that
applicable law prohibits the exclusion of implied warranties, the duration of any applicable plied warranty is limited to theim
same three-year and one-year periods described above if permitted by applicable law. Any oral or written description of the
Products is for the sole purpose of identifying the Products and shall not be construed as an express warr anty. Prior to
using, implementing or permitting use of the Products, you shall determine the suitability of the Products for the intended
use, and you shall assume all risk and liability whatsoever in connection with such determination. We reserve the right to
use functio lly equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty na
service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the
Product was originally installed located in the United States and Canada. This warranty is not extended to resellers.
To Obtain Service Under Limited Warranty: To qualify for warranty service, you must: (a) notify us at the address or
telephone mber stated below within 60 days of the discovery of the defect; (b) give the m el number and serialnu od number;
and (c) describe the nature of any defect in the Product or part. At the time of the request for warranty service, you must
present evi nce of your proof of purchase and proof of the original purchase date. If we determine that the warranty de
exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible
for all shipping, travel, labor and other costs related to the services. This warranty is not exte ed or restarted upon warrantynd
repa or rep ace entsir l m .
Please check our website for any additional Product information, www.zephyronline.com
Zephyr 2277 Harbor Bay Parkway Alameda, CA 94502, ,
TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS
United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact
Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.com
36 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide
Z A Z , Z LC, Z R M , Z R E
I S L A N D
C O R E
Product Registration
Congratulations on the purchase of your
Zephyr product! Please take a moment to
register your new Zephyr product at
www.zephyronline.com/registration
Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368
Prompt registration helps in more ways
than one.
IT’S IMPORTANT
Ensures warranty coverage should you need
service.
Ownership verification for insurance purposes.
Notification of product changes or recalls.
WWW.ZEPHYRONLINE.COM
MAR22.0101
Anzio Island
ZAZ-M90DS
ZAZ-E42DS
Luce Island
ZLC-M90CS
ZLC-E42CS
Roma Island
ZRM-E36FS
ZRM-E42FS
Ravenna Island
ZRE-M90BBSGG
ZRE-E42BBSGG
EN Use, Care, and Installation Guide
FR Guide d’utilisation, dentretien et d’installation
Ai
row Control Technolo
gy
TM
C
2ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
3
ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
ZEPHYRONLINE.COM
Table des matières
Page
Consignes de sécurité 4-6 .......................................................................
Types d’avertissements de curi 4 .....................................................
curi générale 4-5 ...............................................................................
Oration 6 ...........................................................................................
Exigences électriques 6 .........................................................................
Déclaration d’interface de la Federal Communication Commission 6 ...
Liste de matériel 7 ..................................................................................
Instructions d’installation 8-19 ..................................................................
Feuille de calcul pour le conduit d’ration 8 .........................................
Hauteur de montage, dégagement et gaine 9 .......................................
Options de conduits 10 ...........................................................................
ZAZ Spécifications de la hotte 11 ............................................................
ZLC Spécifications de la hotte 12 ............................................................
ZRM Scifications de la hotte 13 ...........................................................
ZRE Spécifications de la hotte 14 ............................................................
Fourniture électrique 15 ..........................................................................
Raccord de câble 15 ...............................................................................
Montage de la hotte 16-18 ........................................................................
Recirculation sans conduit 19 ..................................................................
Fonctionnalités et commandes 20-23 ........................................................
Commandes tactiles ICÔNE 20-21 ............................................................
Técommande RF en option 22-23 ............................................................
Entretien 24-25 ..........................................................................................
Nettoyage de la hotte et du filtre 24-25 .....................................................
LumiLight LED ................................................................................... 25
Conversion ACT™ 26-27 ............................................................................
Technologie de contrôle du flux d’air (ACT™) ..................................... 26
Activer ACT™ ..................................................................................... 27
Schéma de câblage 28-31 ..........................................................................
Dépannage 32-33 .....................................................................................
Liste des pièces et accessoires 34 ...........................................................
Garantie limitée 35 .................................................................................
Enregistrement du produit 36 ..................................................................
4ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
Î L E
C O R E
Z A Z , Z LC, ZR M , Z R E
Consignes de sécurité
Votre sécurité et celle des gens qui vous entourent sont très
importantes.
Ce manuel contient de nombreux messages decuri relatifs
à votre appareil. Lisez tous les messages et conformez-vous-y
en tout temps.
Voici le symbole d’alerte à la sécuri. Ce symbole vous informe
de possibles dangers qui pourraient entraîner de graves lésions
corporelles ou la mort. Tous les messages de sécurité suivent
le symbole d’alerte à la sécuri et comportent les mots «
DANGER AVERTISSEMENT ATTENTION », « » ou « ».
DANGER
AVERTISSEMENT
Le mot « danger » signifie que le fait de ne pas tenir compte
de l’énoncé de sécurité peut entraîner une blessure grave ou
la mort.
Le mot « avertissement » signifie que le fait de ne pas
tenir compte de l’énoncé de sécurité peut entraîner des
dommages importants au produit, une lésion corporelle
grave ou la mort.
Le mot « attention » signifie que le fait de ne pas tenir
compte de l’énoncé decuri peut entraîner une lésion
corporelle mineure ou modérée, ou encore des dommages
au produit ou à la propriété.
LISEZ ET CONSERVEZ CES INSTRUCTIONS
AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE,
DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES,
RESPECTEZ LES SUIVANTS:
a) N’utilisez cet appareil que de la manière prévue par le
fabricant. Si vous avez des questions, contactez le fabricant.
b) Avant l’entretien ou le nettoyage de l’unité, coupez
l’alimentation au panneau de service et verrouillez les moyens
de déconnexion de service pour éviter toute mise sous tension
accidentelle. Lorsque le moyen de déconnexion de service
ne peut pas être verrouillé, fixez solidement un dispositif
d’avertissement bien visible, tel qu’une étiquette, au panneau
de service.
Sécurité générale
ATTENTION
Pour réduire le risque d’incendie ou de choc électrique,
n’utilisez pas ce ventilateur avec un dispositif de commande
à semi-conducteurs.
ATTENTION
AVERTISSEMENT
ATTENTION
Pour Une Ventilation Générale Uniquement. Ne Pas Utiliser
Pour Évacuer Des Matières Et Des Vapeurs Dangereuses Ou
Explosives. Soyez prudent lorsque vous utilisez des produits
de nettoyage pour détergents. Convient pour une utilisation
dans la zone de cuisson domestique.
AVERTISSEMENT
AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE DE
GRAISSE SUR LE HAUT DE CUISINIÈRE:
a) Ne laissez jamais les unités de surface sans surveillance
à des réglages élevés. Les débordements provoquent de la
fumée et des débordements graisseux qui peuvent senflammer.
Chauer les huiles lentement à des réglages faibles ou
moyens.
b) Allumez toujours la hotte lorsque vous cuisinez à feu vif
ou lorsque vous flambez des aliments. (cest-à-dire Crêpes
Suzette, Cerises Jubilee, Boeuf au Poivre Flambé »).
c) Nettoyez fréquemment les ventilateurs de ventilation. La
graisse ne doit pas saccumuler sur le ventilateur ou le filtre.
d) Utilisez une taille de casserole appropriée. Utilisez toujours
des ustensiles de cuisine adaptés à la taille de l’élément de
surface.
7
ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
ZEPHYRONLINE.COM
Liste de matériel
Pièces non fournies
Conduits, conduits et tous les outils d’installation
Connecteur de verrouillage de câble (si requis par les codes locaux)
Couvertures de conduit d’extension
Kit de recirculation en option
Télécommande en option
(3) écrous de fil (4) ø12 DE / ø5
Rondelles ID
(4) M4 x 1 po
les vis à bois
(4) Tête plate 3/16 x 1/4 po
vis mécaniques
(1) Pack matériel
(1) registre rond de 6 po (préinstallé)
CONTENU DE L'EMBALLAGE DU MATÉRIEL
(2) Couvertures
supérieures
de conduit
(1) cadre de support supérieur
(2) Couvertures
inférieures de
conduit (1) Cadre de support inférieur
(1) Hotte
(4) LumiLight LED
(2) Filtres à mailles
(ZAZ-E42 et ZRM-E42 x 3)
(1) M4 x 12
vis de sécurité
A
B
Front of Hood
CL
/
Cut-Out Shaded Area
(1) Modèle de plafond en papier
(20) tête cylindrique M4 x 8
vis mécaniques
(ZLC x 8)
(2) Supports latéraux
(ZLC UNIQUEMENT)
(1) Support carré
(ZAZ UNIQUEMENT)
(4) vis mécaniques àte
cylindrique 3/16 x 1/4
(ZRE uniquement)
8ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
Î L E
C O R E
Z A Z , Z LC, Z R M , Z R E
Instructions d’installation
Total =
3- 1/ 4” x 10” 1 pi x ( ) = pi
5 pi x ( ) = pi
20 pi x ( ) = pi
6”, 7”, 8”, 10” 15 pi
x ( ) = pi
6”, 7”, 8”, 10”
9 pi x ( ) = pi
pi
6”, 7”, 8”, 10” 1 pi x ( ) = pi
Total =
6”, 7”, 8”, 10” 30 pi x ( ) = pi
pi
pi
pi
6”, 7”, 8”, 10” 30 pi x ( ) = pi
1 pi x ( ) = pi
16 pi x ( ) = pi
8 pi x ( ) = pi
23 pi x ( ) = pi
7” to 6” or
8” to 7” circ.
reducteur
conique
25 pi x ( ) = pi
3- 1/ 4” x 10” 15 pi x ( ) = pi
3- 1/ 4” x 10” 9 pi x ( ) = pi
3- 1/ 4” x 10” 24 pi x ( ) = pi
30 pi x ( ) = pi
pi x ( ) = pi
15
6”, 7“, 8”
circ.
bouchone de
l’air
Pièces de conduit Longueur x
Nombre utilisé
rect., droit
circ., droit
rect.,
coude à 90º
rect.,
coude à 45º
rect.,
coude plat
à 90º
circ.,
coude à 90º
coude à 45º
Sous-total - colonne 1=
Longueur maximale du conduit d’aération :
Pour un mouvement d’air convenable, la longueur totale d’un conduit
d’aération ne devrait pas compter plus que l’équivalent de 150 pieds.
Pièces de conduit Longueur x
Nombre utilisé
6” circ. à
rect. de
3-1/4" x 10",
coude à 90º
6” circ. à
rect. de
3-1/4" x 10"
6” circ. à
rect. de
3-1/4" x 10"
6” circ. à
rect. de
3-1/4" x 10",
coude à 90º
7” circ. à
rect. de
3-1/4" x 10"
7” circ. à
rect. de
3-1/4" x 10",
coude à 90º
3-1/ 4” x 10”
embout mural
rect./registre
embout
mural
circ./registre
chapeau de
toiture circ.
Sous-total - colonne 2 =
Sous-total - colonne 1 =
Total du conduit =
Feuille de calcul pour le conduit d’aération
15
ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
ZEPHYRONLINE.COM
Instructions d’installation
Fourniture électrique
Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de
commencer l’installation. N’utilisez pas de rallonge ni de fiche d’adaptateur avec cet appareil.
Suivez les codes électriques nationaux ou les codes et règlements locaux en vigueur.
Cet appareil nécessite une alimentation électrique de 120 V 60 Hz et est connecté à un circuit de
rivation individuel correctement mis à la terre, progé par un disjoncteur de 15 ou 20 ampères
ou un fusible temporisé. Le câblage doit être à 2 fils avec terre. Veuillez également vous référer au
schéma électrique étiqueté sur le produit.
Le câblage électrique doit être eectué par des personnes
qualifiées conformément à tous les codes et normes applicables.
Cette hotte doit être correctement mise à la terre. Coupez
l’alimentation électrique à l’entrée de service avant le câblage.
ATTENTION
Raccord de câble
Un connecteur de verrouillage de câble (non fourni) peut être requis par les codes locaux. Vérifiez les
exigences et les codes locaux, achetez et installez le connecteur approprié si nécessaire. (FIG. A)
Raccord de câble
FIG. A
17
ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation
ZEPHYRONLINE.COM
Instructions d’installation
Montage de la hotte
3. Soulevez l’assemblage du cadre de support
jusqu’au plafond en vous assurant que le mot «
avant » sur le cadre de support supérieur fait face
à l’avant de la hotte où les commandes seront
situées. (FIG. D) Les trous de serrure sur le cadre
de support supérieur doivent couvrir les vis à bois
précédemment installées dans le plafond. Faites
glisser le cadre de support vers l’extrémité étroite
des trous de serrure pour verrouiller le cadre en
place. Installez les (2) dernières vis à bois M6 x 1
po avec rondelles dans les deux coins restants du
cadre de support supérieur pour le xer au plafond.
Serrez toutes les vis.
4. ZRE UNIQUEMENT: retirez les ltres à mailles en
aluminium de la hotte. Placez l’auvent sur le boîtier
du ventilateur et xez-le au corps de la hotte à
l’aide de (4) vis mécaniques à tête cylindrique 3/16
x 1/4 à travers l’ouverture du ltre. (FIG. E).
5. Soulevez le capot et alignez les (4) vis de montage
préinstallées situées sur le dessus du corps de
l’appareil (FIG. A4) avec les (4) trous de clé sur le
bas du cadre de support. (FIG. F). Faites glisser le
capot vers l’extrémité étroite des trous de clé pour
le verrouiller en place. Serrez à la main chacune des
(4) vis avec un tournevis pour xer la hotte au cadre
de support inférieur. Fixez davantage le cadre de
support inférieur au corps de l’unité à l’aide d’une
vis de sécurité M4 x 12. (FIG. G).
6. Retirez le ruban adhésif xant le support de
montage de l’électronique au capot et repositionnez
le support de montage de l’électronique. Installer
les travaux électriques et de conduits.
7. Mettez la hotte sous tension, vériez toutes les
fonctions et recherchez les fuites autour du ruban
adhésif.
FIG. E
BOÎTIER
DU
VENTIL EURAT
FIG. F
Cadre de support inférieur
(se fixe au dessus du boîtier du ventilateur)
Trous de clé
commandes orientées vers l'avant
retour
FIG. G


Specyfikacje produktu

Marka: Zephyr
Kategoria: Okap wyciągowy
Model: ZRE-E42BBSGG

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Zephyr ZRE-E42BBSGG, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Okap wyciągowy Zephyr

Instrukcje Okap wyciągowy

Najnowsze instrukcje dla Okap wyciągowy