Instrukcja obs艂ugi YSI 58
Przeczytaj poni偶ej 馃摉 instrukcj臋 obs艂ugi w j臋zyku polskim dla YSI 58 (40 stron) w kategorii R臋czny. Ta instrukcja by艂a pomocna dla 8 os贸b i zosta艂a oceniona przez 2 u偶ytkownik贸w na 艣rednio 4.5 gwiazdek
Strona 1/40

Operations
Manual


SECTION 1 INTRODUCTION ....................................................................................................................... 1
SECTION 2 PREPARING THE METER...................................................................................................... 2
2.1 UNPACKING .............................................................................................................................................. 2
2.2 WARRANTY CARD .................................................................................................................................. 2
2.3 BATTERIES................................................................................................................................................. 2
SECTION 3 PREPARING THE PROBE....................................................................................................... 3
3.1 CHOOSING THE CORRECT PROBE...................................................................................................... 3
3.1.1 YSI 5239 DO FIELD PROBE ........................................................................................................... 3
3.1.2 YSI 5905 BOD PROBE ..................................................................................................................... 3
3.1.3 YSI 5739 DO PROBE........................................................................................................................ 4
3.1.4 YSI 5718 DO FIELD PROBE ........................................................................................................... 4
3.1.5 YSI 5750 BOD BOTTLE PROBE .................................................................................................... 4
3.2 PROBE INSTALLATION - YSI 5739....................................................................................................... 5
3.3 CHOOSING THE CORRECT MEMBRANE........................................................................................... 5
3.3.1 MEMBRANE INSTALLATION FOR THE 5239 PROBE............................................................ 6
3.3.2 MEMBRANE INSTALLATION FOR THE 5905 PROBE............................................................ 7
3.3.3 MEMBRANE INSTALLATION FOR THE 5700-SERIES PROBES........................................... 8
SECTION 4 OPERATION.............................................................................................................................. 10
4.1 PRINCIPLES OF OPERATION............................................................................................................... 10
4.2 TURNING THE INSTRUMENT ON ......................................................................................................11
4.3 CALIBRATION......................................................................................................................................... 11
4.3.1 AIR CALIBRATION ....................................................................................................................... 12
4.3.2 WINKLER TITRATION................................................................................................................. 13
4.3.3 AIR-SATURATED WATER CALIBRATION .............................................................................13
4.3.4 CALIBRATION FREQUENCY ..................................................................................................... 14
4.4 MAKING MEASUREMENTS................................................................................................................. 14
4.4.1 ENVIRONMENTAL CONSIDERATIONS .................................................................................. 14
4.4.2 MEASURING OXYGEN IN FLUIDS OTHER THAN WATER................................................ 15
4.4.3 CALIBRATING TO DISPLAY OXYGEN PARTIAL PRESSURE IN MM HG....................... 15
4.5 RECORDER OUTPUT ............................................................................................................................. 16
SECTION 5 CARE AND MAINTENANCE................................................................................................ 17
5.1 THE METER CASE.................................................................................................................................. 17
5.2 PROBE PERFORMANCE CHECK......................................................................................................... 17
5.3 PROBE PRECAUTIONS.......................................................................................................................... 17
5.3.1 5905 AND 5239 PROBE CARE ..................................................................................................... 18
5.3.2 5700-SERIES PROBE CARE.......................................................................................................... 19
5.4 PROBE STORAGE ................................................................................................................................... 19
5.4.1 5905 AND 5239 PROBE STORAGE .............................................................................................19
5.4.2 5700 SERIES PROBE STORAGE.................................................................................................. 19
SECTION 6 DISCUSSION OF MEASUREMENT ERRORS.................................................................. 20
SECTION 7 TROUBLESHOOTING............................................................................................................ 21
SECTION 8 WARRANTY AND SERVICE INFORMATION ................................................................ 23
APPENDIX A GENERAL SPECIFICATIONS ......................................................................................... 28
i
Specyfikacje produktu
Marka: | YSI |
Kategoria: | R臋czny |
Model: | 58 |
Potrzebujesz pomocy?
Je艣li potrzebujesz pomocy z YSI 58, zadaj pytanie poni偶ej, a inni u偶ytkownicy Ci odpowiedz膮
Instrukcje R臋czny YSI

17 Wrze艣nia 2024

17 Wrze艣nia 2024

16 Wrze艣nia 2024

15 Wrze艣nia 2024

14 Wrze艣nia 2024

13 Wrze艣nia 2024

13 Wrze艣nia 2024

12 Wrze艣nia 2024

12 Wrze艣nia 2024

12 Wrze艣nia 2024
Instrukcje R臋czny
- R臋czny AEG
- R臋czny Dell
- R臋czny Neumann
- R臋czny Nintendo
- R臋czny Oreck
- R臋czny Sun Joe
- R臋czny Global Water
Najnowsze instrukcje dla R臋czny

24 Wrze艣nia 2024

24 Wrze艣nia 2024

24 Wrze艣nia 2024

24 Wrze艣nia 2024

24 Wrze艣nia 2024

7 Wrze艣nia 2024

6 Wrze艣nia 2024

4 Wrze艣nia 2024

3 Wrze艣nia 2024

28 Sierpnia 2024