Instrukcja obsługi Wolf CGG-1K-24


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Wolf CGG-1K-24 (36 stron) w kategorii kocioł centralnego ogrzewania. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/36
Installation and
operating instructions
Gas red wall mounted boiler
CGG-1K-24/28
Part no. 30 62 087 Subject to modications
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de
11/08 GB
23062087_1108
Index
General information
Safety instructions / Standards and regulations ............................................ 3-4
Operation
Control / Function / Operation ...........................................................................5
Installation
Dimensions / Installation dimensions ................................................................6
Layout CGG-1K-24/28 .................................................................................. 7-8
Positioning information / Installation ..................................................................9
Installation
On nished walls .............................................................................................10
On unnished walls ......................................................................................... 11
Flue gas buttery orice plate / Routing ventilation air / ue gas .............. 12-13
Power connection ............................................................................................14
Commissioning
Filling the system ............................................................................................15
Commissioning / Checking the gas supply pressure ......................................16
Boiler settings and matching
Displaying / modifying control parameters ......................................................17
Limiting the maximum output ..........................................................................18
Selecting the pump stage .......................................................................... 19-20
Commissioning report .....................................................................................21
Inspection and maintenance
Inspection and maintenance / Service report ..................................................22
Service report ..................................................................................................23
Service ...................................................................................................... 24-25
Additional information
Conversion to other gas types .................................................................. 26-31
Flue gas test ....................................................................................................32
Wiring diagram ................................................................................................33
Specication ....................................................................................................34
Fault / Cause / Remedy ..................................................................................35
EC Declaration of Conformity ..........................................................................36
3
3062087_1108
The following symbols are used in conjunction with these
important instructions concerning personal safety as well
as operational reliability.
Safety instructions
This indicates technical instructions that you
must observe to prevent material losses and
boiler malfunctions.
NB
Danger through 'live' electrical components.
NB Switch OFF the ON / OFF switch before
removing the casing.
Never touch electrical components or contacts
when the ON / OFF switch is in the ON position.
This results in a risk of electrocution that may
lead to injury or death.
The main supply terminals are 'live' even when
the ON / OFF switch is in the OFF position.
"Safety instructions" are instructions with
which you must comply exactly, to prevent
injury and material losses.
Fig.: Terminal box: Danger from electric current
Fig.: Gas connection: Escaping gas may cause poisoning or the risk
of explosion
Fig.: Ignition transformer, high voltage ignition electrode, combustion
chamber
Risk of electrocution, risk of burning through hot components
Fig.: Gas combination valve
Danger from electric current
Escaping gas may cause poisoning or the risk of explosion


Specyfikacje produktu

Marka: Wolf
Kategoria: kocioł centralnego ogrzewania
Model: CGG-1K-24

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Wolf CGG-1K-24, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje kocioł centralnego ogrzewania Wolf

Wolf

Wolf CGG-1K-24 Instrukcja

28 Września 2024
Wolf

Wolf FGB-K-35 Instrukcja

28 Września 2024
Wolf

Wolf FGB-K-28 Instrukcja

28 Września 2024
Wolf

Wolf CGB-2-75 Instrukcja

28 Września 2024
Wolf

Wolf CGG-1K-28 Instrukcja

28 Września 2024
Wolf

Wolf FGB-24 Instrukcja

28 Września 2024
Wolf

Wolf CGB-2-100 Instrukcja

28 Września 2024

Instrukcje kocioł centralnego ogrzewania

Najnowsze instrukcje dla kocioł centralnego ogrzewania