Instrukcja obsługi Westinghouse 7254635


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Westinghouse 7254635 (16 stron) w kategorii Wentylator. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
SAA-Havanna-Australia-WH18
OWNER'S MANUAL
Please write model number here for future reference: /
7254635
LED Module#: SMJD-3V16W2P3
Havanna
Net Weight: KGS
240V~50Hz
2
SAA-Havanna-Australia-WH18
1.
Proceed with caution. Read all instructions before beginning the installation.
2.
Only an authorized electrician should execute the installation.
3.
The installation height, i.e. the distance between the blades and the floor, should be at least 2.3 m.
4.
Always maintain the distance between the lamp and inflammable materials (curtains, wall, etc.), as indicated on the pictogram.
5.
Make sure the fan is securely fastened at the ceiling.
6.
WARNING! Do not use a dimmer type switch to control the fan speed.
7.
WARNING! To prevent injuries, make sure the blades are not bent and that there are no objects with in the area of rotation.
8.
WARNING! Due to European safety regulations, if the flush mount option is elected, the fan must not be re-installed utilizing the downrod.
If attempted, this may cause a serious injury. When assembling the fan, please follow your local safety regulations.
9.
WARNING: Do Not use this fan in the same room at the same time as a gas or fuel burning fire, unless the flue has been tested under these conditions of use by a competent person.
10.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user mainte
nance shall not be made by children without supervision.
11.
Suitable for use indoors.
12.
Before disassembling light kit, make sure the power supply is disconnected from the main supply. Power supply can be on only after installation is completed.
13.
The lampshade should not be removed from the light bulb when the power supply is on.
14.
Replacement of light bulb is only possible when the light kit has cooled down, and the power supply is disconnected from the main supply.
15.
Make sure the lampshade is in the fixed position when operating the product.
16.
Means for all poles disconnection having a contact separation that provide full disconnection under over voltage category III conditions must be incorporated in the fixed wiring in
accordance with national wiring rules.
17.
IP20 The fan is designed for indoor use. It is not designed for installation in a bathroom or any damp area. Please ensure that the lamp does not come into contact with water.
18.
WARNING: If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
19.
The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
20.
The fixing means for attachment to the ceiling can be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
21.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
READ AND SAVE THESE INSTRUCTIONS
SAfETy TIpS
3
SAA-Havanna-Australia-WH18
COMBO-BLADE
Combo-Blades feature two high quality finishes on one blade. Select the one that best complements
your decor, or change the style with just a flip of the blade.
NOTE: Combo-Blade finishes vary, depending upon model.
FeAtureS
For normal ceilings
DOWNROD
INSTALLATION


Specyfikacje produktu

Marka: Westinghouse
Kategoria: Wentylator
Model: 7254635

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Westinghouse 7254635, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Westinghouse

Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72076 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72723 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78171 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 73060 Instrukcja

8 Października 2024
Westinghouse

Westinghouse 72598 Instrukcja

8 Października 2024
Westinghouse

Westinghouse 72054 Instrukcja

8 Października 2024
Westinghouse

Westinghouse 78764 Instrukcja

8 Października 2024
Westinghouse

Westinghouse 78708 Instrukcja

8 Października 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

Air King

Air King E130SH Instrukcja

10 Października 2024
TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Clean Air Optima

Clean Air Optima CA-405 Instrukcja

9 Października 2024