Instrukcja obsługi Vitek VT-PIRC2


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Vitek VT-PIRC2 (8 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 21 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
VITEK
Color CCD Image Sensor with 420 TV Lines (VT-PIRC2) /
550 TV Lines (VT-PIRC2/H)
Minimum Illumination of 0.2 Lux / 0.5 Lux (VT-PIRC2/H)
Pinhole 3.8mm / f2.0 Lens Included
NC/C/NO Alarm Output
Working 100’ Motion Detection Using 58 Beams Within 3
layers (35’ x 35’ Coverage Area)
VT-PIRC2
VT-PIRC2/H
Color PIR Cameras
2
PIR BOARD LAYOUT
1. LED: When an intrusion is detected, the LED will activate.
2. J2: Pulse count setting.
Relay will activate when an intrusion is detected once. (For stable 1-2 short (default):
environments or high risk operating environments)
Relay will activate when an intrusion is detected twice within 15 seconds.2-3 short:
(For harsh environments)
3. J1: Relay output select.
For outer control used in area where DC12V is requested (Limited at 200mA).Short:
N.C. = DC12V outNormal:
N.O. = DC12V outActivate:
Caution! Risk of electric shock. Set-up and operation should be
performed by authorized service person only.
Open (default): Normal relay connector (1.5A at DC24V/1.5A at AC120V/1A at
AC240V)
C & N.C. short / C & N.O. open.Normal:
C & N.C. open / C & N.O. short.Activate:
4. VR1: Sensitivity adjustment.
Turn clockwise for low sensitivity, turn counter-clockwise for high.
5. VR2: Relay activation time adjustment (range about 2 ~ 30 seconds).
Turn clockwise for short time, turn counter-clockwise for long.
6. NC/C/NO Wiring:
C: NO: NC: BLACK WHITE RED
7. J3: LED on/off
Open: LED off Short: LED on
CN1 Connector:
1. DC 12V IN
2. GND
3. AUDIO OUT (option)
4. GND
5. VIDEO OUT
6. RELAY C. (common)
7. RELAY N.O. (normal open)
8. RELAY N.C. (normal close)
CN2 Connector:
1. AUDIO IN (Not Available In US)
2. VIDEO IN (from CCD MODULE)
3. GND
4. DC 12V/500mA OUT (for CCD MODULE)
3
Image Device
Effective Pixels
Resolution
Minimum Illumination
PIR Detection Range
PIR Alarm Output
AGC
S/N Ratio
Video Output
Auto Electronic Shutter
Standard Pinhole Lens
Power Source
Power Consumption
Operation Temperature
Humidity
Dimensions (WxHxD)
100° / 35’ x 35’ Coverage Area
NC/N/NO
>18db
More Than 48dB
Composite: 1.0 Vp-p / 75 Ohm
1/60 to 1/100,000 sec.
3.8mm / F2.0
12VDC (300mA Regulated)
150mA
14°F ~ 140°F (-10°C ~ 60°C)
0-95%
2.75” x 4.72” x 1.69” / 70mm x 120mm x 43mm
SPECIFICATIONS VT-PIRC2 VT-PIRC2/H
SPECIFICATIONS
1/4” Color CCD
510 x 492
420 TV Lines
0.2 Lux
1/3” Color CCD
811 x 508
550 TV Lines
0.5 Lux
**12VDC Regulated power adapter 12V must be used otherwise
the device will be damaged and un-repairable.


Specyfikacje produktu

Marka: Vitek
Kategoria: nieskategoryzowany
Model: VT-PIRC2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Vitek VT-PIRC2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Vitek

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024