Instrukcja obsługi Vimar 02912
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Vimar 02912 (3 stron) w kategorii termostat. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/3
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02912 03 2206
02912 - Wi-Fi thermostat
SMART CLIMA
Electronic Wi-Fi thermostat for local control and advanced remote temperature management
via View App, heating and air conditioning in ON/OFF and PID mode, class I temperature
control device (contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode,
configuration via View App on standard Bluetooth technology, 1 digital input, 1 relay output
5(2) A 240 V~, power supply 100-240 V~ 50/60 Hz, white LED backlighting, surface mounting,
white.
Download the View App from the stores onto the tablet/smartphone you will be
using for configuration.
You will also need:
Amazon Alexa, Google Assistant voice assistants for possible voice operation
CONFIGURATION IN
1. Create your Administrator or Installer account on MyVimar (on-line).
2. Wire the thermostat.
3. Start the View App and log in with the credentials you just created.
4. To associate the thermostat:
• In the event of new systems, select “Create smart system” and give it a name. Select the
smart system you just created “Customise” “Smart devices” “Add a device”
“VIMAR Smart Thermostat” “Start”
• In the case of an existing system, select the smart system “Customise” “Smart devices”
“Add a device” “VIMAR Smart Thermostat” “Start”
• Press button B for 5 s; activate the Bluetooth connection on your tablet/smartphone and
approach the thermostat
• Select “Proceed” and set the connection to the Wi-Fi network following the instructions
provided by the wizard
• Name the thermostat and set the time zone
• Go to the “Smart Devices” section and set the thermostat parameters
For details please refer to the manual entitled “Programming thermostats 02912-02913”
available for download from www.vimar.com
OPERATION WITHOUT CONFIGURATION VIA APP.
If configuration is not done via the View App, the thermostat is designed to accommodate
operation in manual mode.
RESETTING THE THERMOSTAT.
The reset restores the factory settings. Within the first 5 minutes within which it is powered, press
button B for 30 s.
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country where the
products are installed.
• The NO-C contact of the relay must be protected against overloads by installing a device, fuse
or automatic 1-way switch, with a rated current not exceeding 10 A.
• Do not connect a SELV circuit to the NO-C and IN-N terminals as there is no double insulation
with on the L-N terminals.
• The device must be installed at a height of 1.5 m above floor level, in a suitable position for the
correct detection of the room temperature, avoiding installation in recesses, behind doors and
curtains, areas affected by heat sources or subject to the flow of forced heating/cooling venti-
lation sources or affected by atmospheric factors. Avoid in particular installation on perimeter
walls or in association with devices which generate heat (e.g. dimmers or lamps).
CHARACTERISTICS.
• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Consumption at 100 V~:
- brightness L1 (low) and relay OFF 0.3 W
- brightness L3 (high) and relay ON 0.85 W
• Consumption at 240 V~:
- brightness L1 (low) and relay OFF 0.5 W
- brightness L3 (high) and relay ON 1 W
• RF transmission power: < 100mW (20dBm).
• Frequency range: 2400-2483.5 MHz.
• Terminals:
- 2 (L and N) for line and neutral
- 2 for digital input 120 - 240 V~ for alarm signalling (for instance boiler shutdown)
Maximum length of the 30 m contact connection cable
- 2 (NO-C) for relay output with voltage-free contact: 5(2) A 240 V~
• 2 front buttons with rocking action for control and settings.
• 1 button (positioned at the bottom) for configuration and reset.
• Side LEDs:
- 2 on the left for signalling Cloud and WiFi connection
- 2 on the right for signalling ON/OFF and relay state
• White LED display for displaying temperature, set point and configuration state signalling.
• Current settable setpoint: 4 °C ÷ 40 °C.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and 30°C, 0.8°C at
the extremes
• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual.
• Temperature control algorithms: configurable PID or ON/OFF.
• Operating temperature: T40 (0 °C +40 °C) (indoor use).÷
• Protection degree: IP20.
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV,
contribution 2%.
• Device in class II
• Number of manual cycles: 3,000
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1.C
• Tracking index: PTI175
• Degree of pollution: 2
• Rated pulse voltage: 4000 V
• Software class: A
• Reading resolution: 0.1 °C
• Settings resolution: 0.1 °C from App and ± 0.5 °C from device
• Update of temperature displayed: every 10 s
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C
• Hourly temperature setting (via App)
• Room temperature during transportation: -25 °C +60 °C
• Clock error: ≤ 1 s per day
• Configuration via View App using Bluetooth technology
• Controllable via View App, Amazon Alexa and Google Assistant voice assistants.
• Dimensions: 106 x 118 x 20.5 mm.
OPERATION.
Using the View App, making use of the WiFi/Internet connection the following can be set:
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection). The operating
mode can be changed from the View App after one ON/OFF cycle
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
• Lighting in standby: high, medium, low, off with default = medium
• Temperature calibration for heating: between -5°C and +5°C with default = 0°C
• Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
• Relay output status: normally open, normally closed; default = normally open
• Control type: On/Off, PID; default = On/Off
• Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
• Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
• Integrative time for PID control: between 5 min and 120 min; default = 20 min
• Derivative time for PID control: between 0 and 255 s, disabled; default = 0
• Cycle time for PID control: between 10 min and 30 min; default = 10 min
In the event of a power outage, once the power is restored, the thermostat restarts with the
operating mode prior to the outage. If the mode set was “Automatic” the thermostat will restart
in “Manual” mode and the first time it reconnects to the Cloud, it will synchronise the time/date
again and then switch to “Automatic” mode.
USE.
The thermostat display shows the current temperature; when you use “ ” and “ ” the set
point being set during the action is displayed.
REGULATORY COMPLIANCE.
RED Directive. RoHS directive. ErP directive.
Standards EN 60730-2-7, EN IEC 60730-2-9, EN 300 328, EN 301 489-17, EN 62311, EN
IEC 63000.
Temperature control device regulation (EU) no. 811/2013.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately
from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the
differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you
want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver electronic
products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area
of at least 400 m
2. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old
equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and/
or recycling materials used in manufacture.
The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries
and Regions. App Store is a service trademark of Apple Inc.
Google is a trademark of Google LLC.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02912 03 2206
CONNECTION WITH CIRCULATION PUMPS, BURNERS, SOLENOID VALVES
VIEWS
• Short press = adjustment of set point from 4°C to 40°C in steps of 0.5°C
• Long press (5 s) = if on standby the thermostat is switched off; if switched OFF
the thermostat is switched on
A
Display
• bt = thermostat in Bluetooth configuration
• off = thermostat off; on = thermostat on
• °C = degrees Celsius; °F = degrees Fahrenheit
• animation from the bottom up = Heating
• animation from the top down = Air conditioning
• Rst = thermostat reset
• PIN = PIN entry prompt
• Alr, Con, Cld, etc. = alarms
B
• Short press = degrees Celsius/Fahrenheit selection
• Long press (5 s) = the thermostat enters the configuration phase (bt)
• Prolonged press (30 s) within the first 5 min of powering = thermostat reset (Rst)
LED indications
• ON green = Cloud correctly connected
• ON red = Cloud not connected
• ON green = WiFi correctly connected
• ON red = WiFi not connected
• ON green = ON thermostat
• OFF = OFF thermostat
• ON white = Active relay
N NINL L NO C1
VIA LE V IC ENZ A 14
ITALY
360 63 MARO S T IC A VI
VIA
ITA
36
N NINL L NO C1
N.B.: L and 1 terminals not for use
Contact for alarm signalling
*
* Generates an alarm notification but does not deactivate the output relay (NO-C)
Alarms
Alr Alarm generated by the wired contact (for instance
Boiler shutdown)
Con No connection to the Wi-Fi network
Cld No connection to the Cloud
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02912 03 2206
INSTALLATION
Using a screwdriver, detach the thermostat from the bracket as shown in the figure.
Fix the thermostat to the bracket using the dedicated attachments shown in the figure.
Make the connections and fix the bracket to the wall.
Caution: Tighten the wall bracket screws, applying sufficient torque without exaggerating, in order to avoid warping it.
TYPES OF INSTALLATION
1
1
2
2
1
Specyfikacje produktu
Marka: | Vimar |
Kategoria: | termostat |
Model: | 02912 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Vimar 02912, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termostat Vimar
29 Grudnia 2024
29 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
15 Grudnia 2024
Instrukcje termostat
- termostat AEG
- termostat TP-Link
- termostat SilverCrest
- termostat Bosch
- termostat Ferroli
- termostat Nobo
- termostat Panasonic
- termostat Theben
- termostat Crestron
- termostat Nexa
- termostat Tesla
- termostat Fenix
- termostat GE
- termostat Taurus
- termostat Siemens
- termostat Ambiano
- termostat Eberle
- termostat BTicino
- termostat Honeywell
- termostat Remeha
- termostat Truma
- termostat Carel
- termostat ORNO
- termostat TFA
- termostat Ariston Thermo
- termostat Intergas
- termostat Grohe
- termostat Google
- termostat Schneider
- termostat Techno Line
- termostat Daikin
- termostat Emos
- termostat Buderus
- termostat Renkforce
- termostat Corbero
- termostat BaseTech
- termostat Viessmann
- termostat Perel
- termostat Trotec
- termostat Somfy
- termostat Tado
- termostat AVM
- termostat Velleman
- termostat Ferguson
- termostat Homematic IP
- termostat Danfoss
- termostat Delta Dore
- termostat Vaillant
- termostat Devolo
- termostat Dimplex
- termostat Baxi
- termostat SPC
- termostat Atag
- termostat Westfalia
- termostat Remko
- termostat Oregon Scientific
- termostat Elro
- termostat Hama
- termostat Netatmo
- termostat Schwaiger
- termostat Hager
- termostat Junkers
- termostat ACV
- termostat Emerson
- termostat Vemer
- termostat Busch-Jaeger
- termostat Elektrobock
- termostat Hunter
- termostat Fibaro
- termostat Salus
- termostat EQ-3
- termostat Emko
- termostat Heatmiser
- termostat Alecto
- termostat Avidsen
- termostat JUNG
- termostat Carrier
- termostat H-Tronic
- termostat EVE
- termostat Elgato
- termostat Wachendorff
- termostat Sygonix
- termostat De Dietrich
- termostat Müller
- termostat Cotech
- termostat RADEMACHER
- termostat Profile
- termostat Nefit
- termostat Agpo Ferroli
- termostat Amfra
- termostat Brennenstuhl
- termostat Itho
- termostat Energenie
- termostat Devi
- termostat Stiebel Eltron
- termostat Elco
- termostat Magnum
- termostat Horstmann
- termostat Tylö
- termostat Oventrop
- termostat King
- termostat Technoline
- termostat Arnold Rak
- termostat Nest
- termostat Itho-Daalderop
- termostat Hive
- termostat Saunier Duval
- termostat Seitron
- termostat Noma
- termostat Plieger
- termostat Aube
- termostat Conrad
- termostat Zehnder
- termostat Bulex
- termostat UPM
- termostat Optima
- termostat AWB
- termostat Finder
- termostat Xavax
- termostat Fantini Cosmi
- termostat Orbis
- termostat Niko
- termostat Boneco
- termostat Grasslin
- termostat Gira
- termostat Wolf
- termostat HQ
- termostat Max
- termostat Eneco
- termostat Frico
- termostat Vasco
- termostat Radson
- termostat Kemot
- termostat EQ3
- termostat Go Green
- termostat Landis Gyr
- termostat Weishaupt
- termostat Extraflame
- termostat ICY
- termostat HomeMatic
- termostat Computherm
- termostat Wattio
- termostat Heimeier
- termostat Mikoterm
- termostat Berker
- termostat Brink
- termostat Drayton
- termostat Bearware
- termostat Oertli
- termostat Cepra
- termostat Heatit
- termostat 2Heat
- termostat Bryant
- termostat Watts
- termostat Eqiva
- termostat Etherma
- termostat Veria
- termostat Emmeti
- termostat Thermy
- termostat Coati
- termostat Essent
- termostat ThermoSmart
- termostat Enda
- termostat Eurotronic
- termostat Hornbach
- termostat POER
- termostat Worcester-Bosch
- termostat Econo-Heat
- termostat VDH
- termostat PECO
- termostat IR-V
- termostat EasyTemp
- termostat Helios (Amfra)
- termostat Tru Components
- termostat Easy Timer
- termostat Z-Wave
- termostat Hugo Muller
- termostat IMIT
- termostat Innogy
- termostat Wallair
- termostat Maico
- termostat Levica
- termostat HomePilot
- termostat Ouellet
- termostat THERMAFLEX
- termostat Yokis
- termostat ChiliTec
- termostat Eliwell
- termostat Plugwise
- termostat Johnson Control
- termostat Webasto
- termostat Drayton Erie
- termostat OJ ELECTRONICS
- termostat Tellur
- termostat RWE
- termostat ATTACK
- termostat Lowes
- termostat Jumo
- termostat Warmup
- termostat Qubino
- termostat STI
- termostat ELKO
- termostat TrickleStar
- termostat Gewiss
- termostat Sinustec
- termostat Rose LM
- termostat Otio
- termostat MundoControl
- termostat GENERAL Life
- termostat Oreg
- termostat Braeburn
Najnowsze instrukcje dla termostat
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
15 Stycznia 2025
14 Stycznia 2025
13 Stycznia 2025
13 Stycznia 2025
13 Stycznia 2025
13 Stycznia 2025