Instrukcja obsługi Ventus W155


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Ventus W155 (100 stron) w kategorii Stacja pogodowa. Ta instrukcja była pomocna dla 16 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/100
0
VENTUS W155
ENGLISH……………………………………………………………………………..PAGE 01
GERMAN……………………………………………………………………………..PAGE 17
DANISH………………………………………………………………………………PAGE 35
NORWEGIAN………………………………………………………………………..PAGE 55
SWEDISH………………………………………………………………………….PAGE 70
FINNISH………………………………………………………………………………PAGE 85
1
W155. Ventus Wireless Weather station
Owners Manual
Thank you for purchasing the new generation of professional weather station. Designed and engineered
with the state-of-art technology and components, this instrument will provide accurate and reliable
measurement of wind speed & direction, wind chill, daily/weekly/monthly/accumulated rainfall,
barometric pressure, weather forecast, indoor/outdoor humidity, temperature, heat index & dew point as
well as radio-controlled alarm clock. Read this manual carefully to fully explore the features and
functions of the new product.
In this package you will nd:
One monitor (Receiver)
One anemometer (Transmitter – transmit wind & outdoor Channel-1 temperature/humidity data)
One rain gauge (Transmitter – transmit rainfall data)
Mounting hardware for rain gauge (2 sets of screws & plastic screw plugs)
Mounting hardware for anemometer (2 pieces of U-shape metal plate, 4 sets of Hex screws & nuts)
One owner’s manual
Additional tools needed for installation
- Small Phillips screwdriver
- Hexagonal Key
- Electric drill
- Pencil
- Level
- Mast, 1 – 1.25 inch (2.54 – 3.18 cm) in diameter (to mount the anemometer)
Installation
The weather station operates at 433MHz and does not require wire installation among the component
parts. To ensure successful installation and the best performance, we recommend you follow the
installation instructions in the order they appear in this manual.
1. Battery & adapter installation for the monitor (receiver)
Main Power source: Plug in the adapter jack into the side of the unit for basic operation and continuous
backlight.
Backup Power: Open the battery door and insert 6 pieces of AA batteries according to the polarity
indicated, close the battery cover.
2
Sea level pressure setting
After battery/adapter installation, the monitor will enter sea level pressure setting mode directly and the
pressure reading will ash. Press or “ to set the sea level pressure value. Press “PRESSURE” to ▲ ▼
conrm the setting and exit. This allows the unit to provide a more accurate weather forecast &
pressure reading.
You can also set the sea level pressure any time after the installation is completed. For more
information, see “WEATHER FORECAST & BAROMETRIC PRESSURE” section.
Note: you may obtain the current sea level pressure from the weather web site for your locate area.
2. Selecting a location for the anemometer
Select a mounting location for the anemometer that is:
- Outdoors, not blocked on top or sides, so wind can freely reach the anemometer
- Within 30 meter open area from the monitor. Reduce distance if obstacles is between the
anemometer & the monitor
The best location for the anemometer is usually mounted on a mast in an open area where wind is not
blocked on top or sides, or above roof level on the building where the monitor is located.
Testing the eective transmission range
Before mounting the anemometer, measure the distance between the monitor & anemometer and be
sure it is within the eective transmission range. It is recommended to perform a simple RF
transmission test before mounting.
1) Place the monitor in your selected indoor location and install adapter & batteries (see “Battery &
adapter installation for the monitor” section above)
2) Place the anemometer horizontally in your selected outdoor location. Loosen the screws on the
battery door with a small Phillips screwdriver and open the battery door. Insert 2 pieces of AA
batteries according to the polarity indicated. Close the battery door and tighten the screws.
3) Hold “CHANNEL/SEARCH” button on the monitor for 3 seconds and the wind direction,
temperature & humidity icons will ash on the display. The monitor is now searching for all remote
sensors for 2 minutes.
4) If valid wind direction, wind speed and channel-1 temperature/humidity readings are shown on the
monitor within 2 minutes, the RF transmission is successful and the anemometer & monitor are
within the eective transmission.
If above readings are not shown after 2 minutes of searching, the transmission is failed.
Shorten the distance between the anemometer & monitor. Reset the anemometer by removing all
batteries from the anemometer & wait for 10 seconds before re-installing the batteries again.
Repeat step 3 & 4 until the transmission is successful.
5) Remove all batteries from the anemometer before mounting and calibration.


Specyfikacje produktu

Marka: Ventus
Kategoria: Stacja pogodowa
Model: W155

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Ventus W155, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Stacja pogodowa Ventus

Ventus

Ventus W210 Instrukcja

3 Października 2024
Ventus

Ventus W640 Instrukcja

3 Października 2024
Ventus

Ventus W154 Instrukcja

3 Października 2024
Ventus

Ventus W225 Instrukcja

3 Października 2024
Ventus

Ventus W232 Instrukcja

20 Września 2024
Ventus

Ventus W160 Instrukcja

18 Września 2024
Ventus

Ventus W233 Instrukcja

15 Września 2024
Ventus

Ventus V193-R Instrukcja

14 Września 2024
Ventus

Ventus W831 Instrukcja

11 Września 2024
Ventus

Ventus W224-7 Instrukcja

11 Września 2024

Instrukcje Stacja pogodowa

Najnowsze instrukcje dla Stacja pogodowa

Hyundai

Hyundai WSP 3080 Instrukcja

15 Października 2024
Livoo

Livoo SL262 Instrukcja

9 Października 2024
Muse

Muse M-085 WS Instrukcja

8 Października 2024
TFA

TFA 30.5045.54 Instrukcja

8 Października 2024
Davis

Davis DAV-6520 Instrukcja

7 Października 2024
Brandson

Brandson 304633 Instrukcja

7 Października 2024
Brandson

Brandson 305385 Instrukcja

7 Października 2024
GlobalTronics

GlobalTronics WT-440 Instrukcja

6 Października 2024