Instrukcja obsługi Vemer Celo


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Vemer Celo (1 stron) w kategorii termostat. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
1User Manual
FLUSH-MOUNTING ELECTRONIC THERMOSTAT
Read all instructions carefully
DIMENSIONS
2
40 42
40
3WIRING DIAGRAM
L N
5A/250V~
Flush-mounting electronic thermostat for temperature control both in heating
and cooling. The device performs actions of type 1B and is intended for
operating in environments with Pollution Degree 2 and Overvoltage Category III
(EN60730-1).
Code Model Description
VE789400 CELO Flush-mounting thermostat - 2 modules 230 VAC
VE789401 CELO-INT Flush-mounting thermostat - 2 modules 230 VAC
SAFETY WARNINGS
During product installation and operation it is necessary to observe the
following instructions:
1) The device must be installed by a qualified person, in strict compliance
with the connection diagrams.
2) Do not power or connect the device if any part of it is damaged
3) After installation, inacessibility to the connection terminals without
appropriate tools must be guaranteed.
4) The device must be installed and activated in compliance with current electric
systems standards.
5) Before accessing the connection terminals, verify that the leads are not live.
6) A protection device against overcurrents should be installed in the electrical
system, upstream of the device.
TECHNICAL SPECIFICATIONS
Power supply:
– 230Vac (-15% ÷ +10%) 50/60Hz
– max absorption: 4 VA / 230Vac
Installation on flush-mounting box with 45 mm height
Terminal block: for cables with a maximum section of 1.5 mm
2
Output: bistable relay 5A / 250 Vac
Summer/winter/off operating mode (with antifreeze)
Regulation type:
on/off with differential fixed at 0.3 ° C
– proportional with 0.8°C band (-0.3 ÷ +0.5 °C) and period 8 minutes
– proportional with 1.5°C band (-0.7 ÷ +0.8 °C) and period 15 minutes
Measurement precision: ± 0.5 °C
Setpoint range: +5 °C ÷ +35°C
Operating temperature: 0 °C ÷ +50 °C
Storage temperature: -10 °C ÷ +65 °C
Operating humidity: 20÷90% non condensing
Protection degree: IP40
Insulation: reinforced among accessible parts (frontal) and all other terminals
V3IS01085-010 Mod. CELO
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/EU (LVD) and 2014/30/EU (EMCD)
is declared with reference to the following harmonized standards:
• CEI EN 60730-2-9
09-2021
6OPERATION
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efcient sorted waste collection for the environmentally friendly disposal of the used device
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
5MOUNTING
• CELO mounting (code VE789400)
It is recommended to install the device at a height of 1.5 meters from the floor,
in an area that reflects as much as possible the average temperature conditions
of the room.
Avoid installation near doors or windows, in niches, behind doors and curtains
or in locations with excess or total lack of ventilation.
Apply the adapter corresponding to the plate of the civil series to be mounted
(see table)
Connect the load and the power supply (see connection diagram)
Insert the device into the adapter
DEVICE
WITH METALLIC FRAME
Flush-mounting box
Intermediate panel
(not supplied)
Cover plate
(not supplied)
DEVICE
CLOSING FRAME
(WHITE / GREY)
The device can be adapted to the cover plates of Berker, Busch-Jaeger, Gira,
Jung and Merten.
The complete list of compatible cover plates is available on the website
www.vemer.it on the product page.
• CELO-INT mounting (code VE789401)
It is recommended to install the device at a height of 1.5 meters from the floor, in
an area that reflects as much as possible the average temperature conditions of the
room.
Avoid installation near doors or windows, in niches, behind doors and curtains or in
locations with excess or total lack of ventilation.
Connect the load and power supply (see connection diagram)
Fasten the device with the metal frame to the flush mounting box
Apply the cover plate and the 50x50mm intermediate panel
Finally insert the closing frame
Brand Series Adapter
ABB Mylos AM
AVE S44 A4
BTICINO Axolute, Axolute AIR BA
Light, Living International, LivingLight, LivingLight AIR BL
GEWISS Chorus GC
VIMAR Arkè, Eikon, Eikon Evo VE
Plana VP
For information on the possibility of adapting the device with plates different
from those shown, contact the Technical Assistance Service.
How to choose the operating mode
The position of the selector shown in the figure
determines the operating mode:
heating operation
Place the selector in this position if the device
controls a heating system.
The relay is closed when the ambient temperature
is below the set value.
operation off:
Put the selector in this position when
the system must remain off for a long period.
In this mode, the antifreeze function is active, which activates the system
if the ambient temperature drops below 2°C.
air conditioning operation:
Put the selector in this position if the device controls a cooling system.
The relay is closed when the ambient temperature is higher than the set value.
How to choose the type of regulation
The position of the jumper shown in the figure
determines the type of adjustment:
A (factory setting):
ON/OFF regulation
with fixed differential at 0.3°C
B: proportional regulation with 0.8°C
band (-0.3°C ÷ + 0.5°C)
and time base 8 minutes
C: proportional regulation with 1.5°C band
(-0.7°C ÷ + 0.8°C) and time base 15 minutes
Important!
To access the jumper it is necessary to remove the cover after disconnecting the
power supply. The position is read by the device only when it is turned on:
it is therefore useless to change the position of the jumper with the device on,
as well as exposing the user to possible electrical discharges.
How to set the temperature
Turn the knob to set the desired temperature value.
The red LED on indicates the activation of the system (relay closed).
Probe failure signal
In the event of a temperature probe failure, the red LED flashes twice per
second.
In this condition, the relay remains open and the temperature regulation is
suspended.
Contact the technical assistance service.
20
25
30 35
15
10 5 °C
4FRONT PANEL AND KNOB REPLACEMENT
The device is supplied fully assembled in the anthracite grey version; to transform it into the white version
it is necessary to replace the front panel and the temperature adjustment knob.
Proceed as follows:
DISASSEMBLY
1. turn the knob counterclockwise until the internal mechanical lock prevents further rotation
(the knob indicator must be at 5°C)
2. insert the tip of a screwdriver in the part indicated in fig. 1 making a slight lever so as to release
the locking teeth of the front panel
3. leverage with the tip of a screwdriver under the knob as shown in fig. 2 until it is completely extracted.
ASSEMBLY
1. check that the jumper for the choice of the adjustment type is in the desired position.
The device is supplied with the jumper in position A (ON / OFF adjustment).
This setting is suitable for most applications and it is recommended to change it only
in case of real need (the functionality of the jumper is described in the “Operation” chapter)
2. place the front panel on the device, first hooking the teeth in the lower part
and then those in the upper part, paying attention to the selector on the right
3. insert the knob pin into the central hole of the thermostat, making sure that
the indicator on the knob is at 5°C
4. check that the knob rotates completely and smoothly from the minimum value
to the maximum value and that the selector moves in the three positions.
Fig. 1
Fig. 2


Specyfikacje produktu

Marka: Vemer
Kategoria: termostat
Model: Celo

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Vemer Celo, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat Vemer

Vemer

Vemer Chronos Key Instrukcja

30 Września 2024
Vemer

Vemer Keo-B LCD Instrukcja

27 Września 2024
Vemer

Vemer TAMB cap Instrukcja

17 Września 2024
Vemer

Vemer Klima 2V Instrukcja

29 Sierpnia 2024
Vemer

Vemer Klima LCD Instrukcja

28 Sierpnia 2024
Vemer

Vemer Aros Instrukcja

26 Sierpnia 2024
Vemer

Vemer Chronos Instrukcja

22 Sierpnia 2024
Vemer

Vemer Evo Din Instrukcja

6 Sierpnia 2024

Instrukcje termostat

Najnowsze instrukcje dla termostat

Siemens

Siemens RDG100T Instrukcja

15 Października 2024
Junkers

Junkers TA 21E Instrukcja

14 Października 2024
Oreg

Oreg AT90E Instrukcja

9 Października 2024
Oreg

Oreg AT60E Instrukcja

9 Października 2024
Heatit

Heatit PRO Instrukcja

9 Października 2024
Heatit

Heatit MULTIREG6 Instrukcja

9 Października 2024
Avidsen

Avidsen HomeFlow W Instrukcja

9 Października 2024
ORNO

ORNO OR-SH-17701 Instrukcja

8 Października 2024
ORNO

ORNO OR-SH-17702 Instrukcja

8 Października 2024
STI

STI -9102 Instrukcja

8 Października 2024