Instrukcja obsługi Uni-T UT30H

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Uni-T UT30H (1 stron) w kategorii Thermometer. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
P/N:110401109418X
PREFACE
Thank you for purchasing the new infrared thermometer. In order to use this product safely and
correctly, please read this manual thoroughly, especially the part. After reading Safety Instructions
this manual, it is recommended to keep the manual at an easily accessible place, preferably close
to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and workmanship within
one year from the purchase date. This warranty does not apply to damages caused by accident,
negligence, misuse, modification, contamination or improper handling. The dealer shall not be
entitled to give any other warranty on behalf of Uni-T rend. If you need warranty service within the
warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or
loss caused by using this device.
OVERVIEW
SAFETY INSTRUCTION
Warning:
To use the product properly, please read the following instructions carefully before use:
Warning or Caution Read the manual before use
Dispose the device and accessories properly according to local waste management policy.
Direct current
LCD FUNCTION DESCRIPTION
ACCESSORIES
Battery ----------------------------- 2
Manual ----------------------------- 1
Device ------------------------------ 1
SPECIFICATION
SYMBOLS
FAULT DIAGNOSIS
UT30H Non-contact lnfrared Thermometer (hereinafter referred to as "thermometer"). This product
measures temperature by collecting the infrared thermal radiation energy emitted by target surface.
UT30H has advantages of simple and sanitary operation, quick and accurate measurement. It can
measure temperature precisely within 1s by aiming the detector at target object.
It is not allowed to be used in the presence of a mixture of flammable anesthetic gas, air, oxygen or
nitrous oxide. UT30H is a continuous operating device.
This product is composed of infrared sensor, circuit components, operating buttons and plastic shell.
WORKING PRINCIPLE
lnfrared thermometer can measure surface temperature of opaque objects. Its optical device can sense
the infrared energy concentrated on the detector, and the electronic components convert information
into temperature reading which is displayed on the display screen.
OPERATING METHODS
To measure temperature, allow the thermometer aim at the measured target, push the trigger to display
the real time measured result; and loose the trigger to hold it. Thermometer will automatically shut
down if no action were detected out within 15s.
SETTING OPERATION
Symptom
HI (on the screen)
LO (on the screen)
Battery icon flashes
Possible blank screen
Problem
Target temperature exceeding range
Target temperature lower than range
Battery low
Battery drained
Action
Select the target within range
Select the target within range
Replace battery
Check and/or replace battery
To ensure safety and accuracy of measurement, only qualified maintenance personnel can repair
it with original components.
Replace the battery immediately once the battery indicator appears.
Prior to using the thermometer, please check the box. If any damage to the thermometer were
found, please do not use it. Inspect for damage or any shortage of parts.
Do not place the thermometer near the objects with high temperature for long period.
It is recommended to operate the thermometer within the environment of 15°C~35°C and RH<85%.
Please use the thermometer indoor and do not expose it to strong sunlight or intense electromagnetic
interference.
Please ensure the temperature around the measuring object is stable, do not test during strong
airflow.
Avoid testing in unstable temperature environment - wait 30min to allow the thermometer to stable.
Wait 10~30min to measure if the measuring object came from very high or very low temperature.
Please wait 10min to measure new objects after measuring very high or very low temperature.
It is recommended to measure thrice for every object and the highest occurring data should be used.
Please accurately aim the sensor window at the measuring target. Otherwise error or HI/LO
indicator will appear.
Please keep the battery out of the reach of children, children may accidentally ingest. Contact with
doctor immediately if that happens.
If the thermometer will not in use for long period, please take out the battery to avoid leakage.
The battery is not allowed to be placed in fire.
Object measurement mode
Body measurement mode
Buzzer
Battery status
Unit of temperature
Measured temperature value
Power On
With thermometer off, short press the trigger to power on, and the last measurement data before shut
down will be displayed after self-inspection.
Power Off
Thermometer will automatically shut down and save the measured value and current serial number
if no action was detected out within 15s.
Temperature Measurement
1. Aim the thermometer at the measured target, press and hold the trigger, the measured temperature
area will be cleared. Then release the trigger, the measured data will be updated.
2. When the measured temperature exceeds 37.2°C, the buzzer will beep.
3. LO displays when the target temperature is lower than the range; displays when the target HI
temperature is exceeding the range. The buzzer will beep when the target temperature is out of the
range
Mode Setting
In the main interface, short press the button to switch between body/object temperature MODE
measurement mode.
Unit Setting
In the main interface, short press the button twice to enter unit setting, short press button SET SEL
to switch the unit between °C or °F.
Buzzer Setting
In the main interface, short press the button thrice to enter buzzer setting interface, and short SET
press button to switch buzzer on or off. SEL
EXTERNAL STRUCTURE
Infrared Sensor
Trigger
LCD
SET Button
MODE Button
SEL Button
Battery cover
1
2
3
4
5
6
7
1
2
3
4
5
6
7
FEATURES
White backlight
Option of Celsius/Fahrenheit
Dynamic monitoring of battery capacity
Low voltage indication
Display screen
Sound alarm for the upper and lower temperature limit
MAINTENANCE
BATTERY REPLACEMENT
Measurement Range(Object)
Accuracy (Object)
Measurement Range(Body)
Accuracy (Body)
Resolution
Optimum measuring distance
Unit conversion (°C/°F)
Measurement alarm
Power-on Self-test
Auto shutdown
Backlight
Battery type
Operating environment
Transport and storage environment
Operating atmosphere
0°C 100 32.0 212~ °C ( °F~ °F)
± ± )1.0 2.0°C ( °F
32.0°C-45.0°C 89.6 113.0 ( °F~ °F)
35.0°C 42.0°C: 0.2 0.4~ °C ( °F)±±
32.0°C 34.9°C, 42.1°C 45.0°C: 0.3°C 0.5~ ~ ( °F)± ±
0.1°C
1-5cm
Support
Sound alarm for >37.2°C
Support
Support
Support
1.5V x 2 AAA
15°C~35°C (59 F-95 ), <85%RH° °F
-20°C~60°C (-4 ~140 ), <93%RH°F °F
700hPa-1060hPa
The thermometer is a repeatedly-used accurate device. Please pay attention to clean and
maintenance. Especially keep the lens clean, or the accuracy may be affected.
Clean:
1. Clean chassis: Clean the chassis with cotton sponge or soft cloth with
medicinal alcohol or clean water.
2. Clean lens: Blow away the slipped off grains with clean compressed air.
Wipe the surface carefully with wet cotton swab. Cotton swab should be
moistened with medicinal alcohol or clean water.
If the thermometer will not in use for long period, please take out the
batteries to avoid leakage. Please dispose the waste batteries properly.
Open the battery cover to take out the batteries. Load 2 new AAA batteries
correctly and close the battery cover.
Battery

Specyfikacje produktu

Marka: Uni-T
Kategoria: Thermometer
Model: UT30H

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Uni-T UT30H, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Thermometer Uni-T

Uni-T

Uni-T A61 Instrukcja

2 Października 2024
Uni-T

Uni-T UT325F Instrukcja

2 Października 2024
Uni-T

Uni-T A63 Instrukcja

2 Października 2024
Uni-T

Uni-T UT320T Instrukcja

2 Października 2024
Uni-T

Uni-T UT30H Instrukcja

2 Października 2024
Uni-T

Uni-T UT320D Instrukcja

2 Października 2024
Uni-T

Uni-T UT305C Instrukcja

2 Października 2024
Uni-T

Uni-T UT306A Instrukcja

2 Października 2024
Uni-T

Uni-T UT303A+ Instrukcja

2 Października 2024

Instrukcje Thermometer

Najnowsze instrukcje dla Thermometer

Hartmann

Hartmann Veroval DS 22 Instrukcja

2 Października 2024
Thermoval

Thermoval Duo Scan Instrukcja

30 Września 2024
Thermoval

Thermoval Rapid Instrukcja

30 Września 2024
Scala

Scala SC 1504 Instrukcja

30 Września 2024
Scala

Scala SC 2481 Instrukcja

30 Września 2024
Scala

Scala SC 313 flex Instrukcja

30 Września 2024
Scala

Scala SC 17 Instrukcja

30 Września 2024
Scala

Scala SC 212 Instrukcja

30 Września 2024
Scala

Scala SC 42TM Instrukcja

30 Września 2024