1
Owner’s Manual
Sine Wave DC-to-AC Inverter/Charger
Model: APSX4048SW
48 VDC to 230 VAC
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite.
Table of Contents
Important Safety Instructions 2
1. Overview & Features 3
1.1 Overview 3
1.2 Front Panel Controls, LCD Screen 3
and LED Indicators
1.3 Optional Features 4
2. Battery Charger 4
2.1 Mode of Operation 4
2.2 Transfer Switching Speed 4
3. Battery Installation 4
and Maintenance
3.1 Select Battery Type 4
3.2 Monthly Maintenance 6
3.3 Battery Installation 6
3.4 Battery Connection 6
4. Inverter/Charger Single-Phase 9
Installation
4.1 Installation 9
4.2 Installation Diagrams and Charts 9
4.3 Installation and Start-Up 10
4.4 Single-Phase Parallel Stacking 11
Installation and Start-Up
5. Inverter/Charger 3-Phase 13
Parallel Installation
5.1 Installation 13
5.2 Installation Diagrams and Charts 13
5.3 Installation and Start-Up 14
6. Operation 16
6.1 Modes of Operation 16
(Single and 3-Phase)
6.2 Settings and Parameters 18
6.3 Single-Phase Parallel Operation 20
6.4 3-Phase Parallel Operation 21
7. Technical Specifications 22
8. Troubleshooting 22
9. Service 23
Русский 24
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $50 value!
www.tripplite.com/warranty
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite Inverter/Chargers.
Location Warnings
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously
inhibit the unit’s internal cooling, eventually causing product damage not covered under warranty.
• Install your Inverter/Charger in a location or compartment that minimizes exposure to heat, dust, direct sunlight and
moisture. Flooding the unit with water will cause it to short-circuit and could cause personal injury due to electric shock.
• For proper ventilation, allow a minimum 2 inches of clearance at front and back of the Inverter/Charger. To avoid overheating
the Inverter, the compartment that houses the Inverter/Charger must be properly ventilated with adequate outside air flow.
The heavier the load of connected equipment, the more heat will be generated by the unit.
• Do not install the Inverter/Charger near magnetic storage media, as this may result in data corruption.
• Do not install the Inverter/Charger near flammable materials, fuel or chemicals.
Battery Connection Warnings
• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
• Because explosive hydrogen gas can accumulate near batteries if they are not well ventilated, do not install batteries in a
“dead air” compartment. The battery compartment should have some ventilation to outside air.
• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
• Do not allow objects to contact the DC input terminals. Do not short or bridge these terminals together. Serious personal
injury or property damage could result.
Ground Connection Warnings
• Safe operation requires connecting the Inverter/Charger’s Main Ground Terminal directly to the frame of the vehicle or
earth ground.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause
the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not
use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the
output of the Inverter/Charger.
• User must supply proper protection for wire openings in unit panels.
Operation Warnings
• Your Inverter/Charger does not require routine maintenance.
• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply is connected. During any service
work, the battery supply should therefore be disconnected.
• Do not connect or disconnect batteries while the Inverter/Charger is operating from the battery supply. Dangerous arcing may
result.
Status
APSX4048SW
UP
DOWN
SET ENTER
Fault
3 54
1
2
7
8
6
3
1. Overview and Features
1.1 Overview
• Tripp Lite’s APSX4048SW Sine Wave Inverter/Charger is a heavy-duty unit generating a pure sine wave in single-phase or
3-phase power from a 48V battery bank. The APSX4048SW can supply power to a wide range of connected equipment,
from heaters, air conditioners, refrigerators and vacuum cleaners to computers and peripheral devices. The APSX4048SW is
designed to work in heavy load conditions, so de-rating is unnecessary.
• The APSX4048SW’s smart charger is compatible with various battery types and sizes. The switch module automatically
diverts the energy transfer path between the Inverter and an AC input. When the AC source is lower than the transfer level,
the electrical path switches to the Inverter and draws power from the battery source. Otherwise, the load is powered by the
AC input.
1.2 Front Panel Controls
1.2.1 Controls, LCD Screen and LED Indicators
1 This 2-line dot matrix display LCD Screen:
indicates a wide range of power inverter
operating conditions and diagnostic data. It
also displays Inverter/Charger settings and
options when in SETTING mode.
2 This button offers 3 main ON/OFF Button:
functions depending on the power input
when pressed:
• CHARGING/STANDBY switching
(when used with AC input).
• INVERTING/STANDBY switching
(when used with DC input).
• STANDBY mode
(AC bypass output and no charge).
3 Return to previous page.SET Button:
4 This button allows you DOWN Button:
to browse through different operating
conditions and options on the LCD display.
Pressing down the DOWN button for an
extended duration allows the cursor in the
LCD screen to change to a different position.
5 UP Button: This button allows you to browse through different operating conditions and options on the LCD display.
Pressing down the UP button for an extended duration allows the cursor in the LCD screen to change to a different
position.
6 This button allows you to select an item in the menu.ENTER Button:
7 STATUS LED
8 FAULT LED: This red light will flash when your inverter detects an internal fault (overheating, overvoltages, etc.) or when it
detects a wiring fault from the AC or DC power source (reversed phases, missing ground, etc.).
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | Akumulator |
Model: | PowerVerter APSX4048SW |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite PowerVerter APSX4048SW, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Akumulator Tripp Lite
30 Grudnia 2025
8 Października 2024
7 Września 2024
31 Sierpnia 2024
29 Sierpnia 2024
27 Sierpnia 2024
25 Sierpnia 2024
24 Sierpnia 2024
21 Sierpnia 2024
3 Lipca 2024
Instrukcje Akumulator
- Akumulator Sony
- Akumulator Leica
- Akumulator LG
- Akumulator Worx
- Akumulator Huawei
- Akumulator Milwaukee
- Akumulator Bosch
- Akumulator Epson
- Akumulator Parkside
- Akumulator Hikvision
- Akumulator Cramer
- Akumulator Stiga
- Akumulator Toolcraft
- Akumulator Panasonic
- Akumulator Canon
- Akumulator Nedis
- Akumulator Enphase
- Akumulator Black & Decker
- Akumulator Speed-Link
- Akumulator Gardena
- Akumulator DeWalt
- Akumulator Einhell
- Akumulator APC
- Akumulator Husqvarna
- Akumulator Shure
- Akumulator Petzl
- Akumulator Nikon
- Akumulator Ozito
- Akumulator Fuxtec
- Akumulator Scosche
- Akumulator Sungrow
- Akumulator DJI
- Akumulator RYOBI
- Akumulator Deltaco
- Akumulator Cobra
- Akumulator JVC
- Akumulator Trust
- Akumulator Biltema
- Akumulator Hilti
- Akumulator Digitus
- Akumulator Ansmann
- Akumulator Growatt
- Akumulator Victron Energy
- Akumulator Sennheiser
- Akumulator Fluke
- Akumulator Aluratek
- Akumulator Abus
- Akumulator Hama
- Akumulator Fein
- Akumulator Watson
- Akumulator Arris
- Akumulator Nitecore
- Akumulator CyberPower
- Akumulator PowerPlus
- Akumulator Vonroc
- Akumulator McCulloch
- Akumulator Stinger
- Akumulator PowerBass
- Akumulator Xtorm
- Akumulator TOA
- Akumulator Monacor
- Akumulator Metabo
- Akumulator EGO
- Akumulator Bolt
- Akumulator Varta
- Akumulator Greenworks
- Akumulator A-solar
- Akumulator Vetus
- Akumulator Targus
- Akumulator Hähnel
- Akumulator Energenie
- Akumulator Kensington
- Akumulator Techly
- Akumulator Sandberg
- Akumulator Valcom
- Akumulator Cortina
- Akumulator Carat
- Akumulator Conrad
- Akumulator For_Q
- Akumulator Genaray
- Akumulator HQ
- Akumulator Ranex
- Akumulator Wentronic
- Akumulator SKROSS
- Akumulator Energizer
- Akumulator Thomann
- Akumulator Team Orion
- Akumulator SolarEdge
- Akumulator BlackVue
- Akumulator Venom
- Akumulator Duracell
- Akumulator Anova
- Akumulator Red Power
- Akumulator Ultron
- Akumulator Whistler
- Akumulator PNY
- Akumulator PowerDrive
- Akumulator LSI
- Akumulator Variotek
- Akumulator Lenmar
- Akumulator Renata
- Akumulator Fxlion
- Akumulator SOUNDBOKS
- Akumulator FeinTech
- Akumulator Verico
- Akumulator Levolta
- Akumulator HART
- Akumulator APSystems
- Akumulator TCW Technologies
- Akumulator Enerdrive
- Akumulator Ventev
- Akumulator PAG
Najnowsze instrukcje dla Akumulator
3 Stycznia 2025
2 Stycznia 2025
31 Grudnia 2025
30 Grudnia 2025
30 Grudnia 2025
29 Grudnia 2024
28 Grudnia 2024
28 Grudnia 2024
25 Grudnia 2024
25 Grudnia 2024