Metered Rack PDU
Models:
PDUMV30, PDUMV30HV, PDUV30HV, PDUV30-36,
PDUMV20HV, PDUMV20HVL6, PDUMV20HV-36,
PDUV20HVL6-72
(Series Numbers: AGIB6672, AGPD6673, AGPD6674)
Important Safety Instructions 2
Important Warnings 2
Installation 3
Features 3
Warranty & Product Registration 4
Español 5
Français 9
Русский 13
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
PRODUCT REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR®
surge protector in our monthly drawing!
tripplite.com/warranty
20-09-042 indb 1
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will void the
product warranty.
Important Warnings
The PDU provides convenient multiple outlets but it DOES NOT provide surge or line noise
protection for connected equipment.
The PDU is designed for indoor use only in a controlled environment away from excess moisture,
temperature extremes, conductive contaminants, dust or direct sunlight.
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
Do not connect the PDU to an ungrounded outlet or extension cords or adapters that eliminate
the connection to ground.
The power requirement for each piece of equipment connected to the PDU must not exceed the
individual outlet’s load rating.
The total power requirement for equipment connected to the PDU must not exceed the
maximum load rating for the PDU.
Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
Do not attempt to modify the PDU, including the input plugs and power cables.
Do not attempt to use the PDU if any part of it becomes damaged.
Do not attempt to mount the PDU to an insecure or unstable surface.
Never attempt to install electrical equipment during a thunderstorm.
Install in accordance with National Electrical Codes. Be sure to use the proper overcurrent
protection for the installation, in accordance with the plug rating/equipment rating as follows:
Model Series Number Overcurrent Protection
PDUV30HV AGIB6672 30A
PDUV20HVL6-72 AGIB6672 20A
PDUMV30 AGPD6673 30A
PDUMV16HV,
PDUMV20HV,
PDUMV20HVL6,
PDUMV20HV-36
AGPD6674 20A
PDUMV30HV AGPD6675 30A
20-09-042 indb 2
3
Installation
Note: Regardless of configuration, the user must determine the
fitness of hardware and procedures before mounting. The PDU
and included hardware are designed for common rack and rack
enclosure types and may not be appropriate for all applications.
1A
Zero U Rack Configuration (Mounting Brackets). Prior to
installation, determine the rack location in which the PDU is
to be installed. Attach the mounting brackets to the back of
the PDU as shown, using the included screws. To assist with
proper positioning, the brackets have four screw holes each;
make sure that the same two holes are used to attach each
bracket to the PDU. After attaching the brackets, position
the PDU in the rack and mount it by installing four user-
supplied fasteners through the brackets into the rack.
1B
Zero U Rack Configuration (Mounting Buttons). Attach
the included mounting buttons to the PDU. Position the PDU
as desired in the rack enclosure, align the buttons with the
rack mounting slots, and slide the PDU into position.
1C
Under-Counter Configuration. The PDU may be installed
under a counter using the included mounting brackets.
Attach the mounting brackets to the back of the PDU as
shown in STEP 1A. Secure the PDU to the underside of the
counter by installing two user-supplied screws through each
bracket into the counter.
Note: Your model may differ.
1C
1B
1A
5
16432
Features
NEMA 5-15/20R Outlet (PDUMV30, PDUV30-36)
C13 Outlet (PDUMV20HV, PDUV20HVL6-72, PDUMV20HVL6, PDUMV20HV-36,
PDUMV30HV, PDUV30HV)
C19 Outlet (PDUMV20HV, PDUV20HVL6-72, PDUMV20HVL6, PDUMV20HV-36,
PDUMV30HV, PDUV30HV)
L5-30P, L6-20P or L6-30P Locking Plug
Circuit Breaker: If the current drawn by the equipment connected to the PDU exceeds
the Maximum Load Rating, the circuit breaker will trip to prevent possible damage. When the
circuit breaker trips, its plunger will pop up. Disconnect excess equipment and allow the
breaker to cool at least one minute before depressing the plunger to reset the breaker.
Ammeter: The total electrical current used by the PDU will be displayed on the digital meter
in amperes (select models only).
1
2
3
4
6
5
20-09-042 indb 3


Specyfikacje produktu

Marka: Tripp Lite
Kategoria: Listwa zasilająca
Model: PDUV30HV

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Tripp Lite PDUV30HV, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Listwa zasilająca Tripp Lite

Instrukcje Listwa zasilająca

Najnowsze instrukcje dla Listwa zasilająca

Bauhn

Bauhn AP5W-0624 Instrukcja

15 Października 2024
Bauhn

Bauhn AP6W-0324 Instrukcja

15 Października 2024
Hama

Hama PowerCube 00223195 Instrukcja

9 Października 2024
CyberPower

CyberPower P0420SUD0-DE Instrukcja

9 Października 2024
CyberPower

CyberPower B0520SC0-DE Instrukcja

9 Października 2024
GoGen

GoGen SP16A5 Instrukcja

7 Października 2024
Bachmann

Bachmann Desk 2 Instrukcja

1 Października 2024