Instrukcja obsługi Tripp Lite PDUMH16HV
Tripp Lite
Listwa zasilająca
PDUMH16HV
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tripp Lite PDUMH16HV (36 stron) w kategorii Listwa zasilająca. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/36
Owner’s Manual
Metered Rack PDU
Model: PDUMH16HV
(Series Number: AG-00D9)
Important Safety Instructions 2
Installation 3
Features 5
Warranty & Product Registration 7
Español 8
Français 15
Русский 22
Deutsch 29
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
18-11-319-93331C.indb 1 2/20/2019 4:44:40 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions may affect your
warranty.
Important Warnings
• Operate the PDU at indoor temperatures between 32°F and 104°F (between 0°C and 40°C)
only.
• Provide adequate protection against excess currents, short circuits, and ground faults in
accordance with local and national electrical code, such as NEC in the U.S.
• The mains socket that supplies the PDU should be near the PDU and easily accessible.
• The PDU provides convenient multiple outlets but it DOES NOT provide surge or line noise
protection for connected equipment.
• The PDU is designed for indoor use only in a controlled environment away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• Do not connect the PDU to an ungrounded outlet or extension cords or adapters that
eliminate the connection to ground.
• The power requirement for each piece of equipment connected to the PDU must not exceed
the individual outlet's load rating.
• The total power requirement for equipment connected to the PDU must not exceed the
maximum load rating for the PDU.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
• Do not attempt to modify the PDU, including the input plugs and power cables.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Never attempt to install electrical equipment during a thunderstorm.
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• The PDU must be installed by a qualified technician only.
• Install in accordance with local electrical codes. Be sure to use the proper over current
protection for the installation, in accordance with the plug rating/equipment rating.
• The electrical sockets supplying power to the equipment shall be installed near the equipment
and be easily accessible.
18-11-319-93331C.indb 2 2/20/2019 4:44:40 PM
3
Installation
Note: Regardless of installation configuration, the user must determine the fitness of hardware
and procedures before mounting. The PDU and included hardware are designed for common
rack and rack enclosure types and may not be appropriate for all applications. Exact mounting
configurations may vary.
1-1 1U Rack Installation. Attach the PDU to
the rack by inserting four user-supplied
screws A through the PDU mounting
brackets B and into the mounting holes of
the rack rail as shown.
1-2 0U Rack Installation. Part 1: Remove the
screws C attaching the mounting brackets
to the PDU, change the orientation of the
brackets as shown and reattach the
brackets. Use only the screws supplied by
the manufacturer or their exact equivalent
(#6-32, 1/4” flat head). Attach the Part 2:
PDU vertically by inserting two or more user-
supplied screws A through the PDU
mounting brackets B and into mounting
points in the rack or rack enclosure.
1-3 Wall Installation. After repeating Part 1
above, attach the PDU to a stable mounting
surface by inserting two or more user-
supplied screws A through the PDU
mounting brackets B and into secure
mounting points on the mounting surface.
1-4 Under-Counter Installation. After repeating
Part 1 above, attach the PDU to a stable
mounting surface by inserting four user-
supplied screws A through the PDU
mounting brackets B and into secure
mounting points on the mounting surface.
1-1
1-4
1-2
1-3
A
A
B
B
A
A
B
B
C
C
C
18-11-319-93331C.indb 3 2/20/2019 4:44:41 PM
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | Listwa zasilająca |
Model: | PDUMH16HV |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite PDUMH16HV, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Listwa zasilająca Tripp Lite
21 Września 2024
14 Września 2024
13 Września 2024
11 Września 2024
10 Września 2024
9 Września 2024
9 Września 2024
9 Września 2024
8 Września 2024
7 Września 2024
Instrukcje Listwa zasilająca
- Listwa zasilająca Sven
- Listwa zasilająca Yato
- Listwa zasilająca StarTech.com
- Listwa zasilająca Nedis
- Listwa zasilająca ATen
- Listwa zasilająca APC
- Listwa zasilająca Icy Box
- Listwa zasilająca Gembird
- Listwa zasilająca V7
- Listwa zasilająca Digitus
- Listwa zasilająca EVOline
- Listwa zasilająca Oehlbach
- Listwa zasilająca DataVideo
- Listwa zasilająca Panduit
- Listwa zasilająca Intellinet
- Listwa zasilająca Kindermann
- Listwa zasilająca Ewent
- Listwa zasilająca GoGen
- Listwa zasilająca Oregon Scientific
- Listwa zasilająca Hama
- Listwa zasilająca Ubiquiti Networks
- Listwa zasilająca CyberPower
- Listwa zasilająca Vivanco
- Listwa zasilająca Eaton
- Listwa zasilająca Geist
- Listwa zasilająca Anton/Bauer
- Listwa zasilająca Brennenstuhl
- Listwa zasilająca Eglo
- Listwa zasilająca Caliber
- Listwa zasilająca Eminent
- Listwa zasilająca Energenie
- Listwa zasilająca Steren
- Listwa zasilająca Ufesa
- Listwa zasilająca Konig
- Listwa zasilająca HQ
- Listwa zasilająca REV
- Listwa zasilająca Panamax
- Listwa zasilająca Furman
- Listwa zasilająca Legrand
- Listwa zasilająca Bachmann
- Listwa zasilająca Kondator
- Listwa zasilająca Bauhn
- Listwa zasilająca Altronix
- Listwa zasilająca Middle Atlantic
- Listwa zasilająca Huslog
Najnowsze instrukcje dla Listwa zasilająca
14 Stycznia 2025
12 Stycznia 2025
31 Grudnia 2025
29 Grudnia 2024
24 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024