Instrukcja obsługi Theben TheLuxa P300 BK

Theben detektor ruchu TheLuxa P300 BK

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Theben TheLuxa P300 BK (5 stron) w kategorii detektor ruchu. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/5
1
theLuxa P220 WH 1010605
theLuxa P220 BK 1010606
theLuxa P300 WH 1010610
theLuxa P300 BK 1010611
310481 04
Motion detectors
EN
1. Basic safety information
Danger of death through electric shock or fire!
¾ Installation should only be carried out by a
qualied electrician!
WARNING
The device conforms with EN 60669-2-1 if correctly
installed
IP 55/54 according to EN 60529 (depending on type of
installation)
2. Proper use
Motion detector for automatic lighting control dependent
on presence and brightness
Suitable for external wall or ceiling installation
Suitable for entrances, garages, gardens, corridors, parks,
etc.
Only intended for installation outside of arm's reach
Disposal
Dispose of device in environmentally sound manner.
3. Description
3 potentiometers for
setting time (min),
brightness (lux) and
sensitivity (metres)
Motion detector
with sensor head
4. Connection
Disconnect power source!
Ensure device cannot be switched on!
Check absence of voltage!
Earth and bypass!
Cover or shield any adjacent live components.
D1, D2: Suited for switching FELV or a voltage of the same
phases as L.
5. Installation
IP 54
(category II)
IP 55
(category II)
If applicable, use optional corner bracket (9070904,
9070905) or spacer frame (9070908, 9070909) for exible
installation as well as cable entry from side or top/bottom.
0FF
1
230V
2
OR
INTERNAL
EXTERNAL
Knob out hole
Knob out hole
3
Cut out
here
Cut out
here
OR
INTERNAL EXTERNAL
4
2
5
6
INTERNAL EXTERNAL
φ
6mm
φ
6mm
or
7
or
8 9
Tighten the screws.
10 11
230V
Disconnect power source.
Make marks for the holes on the wall (with enclosed drill
template/base).
Drill holes.
Ø 6 mm
60mm
Feed cable through the seal of the base.
Fasten base (and spacer frame) to the wall.
OR
L
N
D1, D2
N
brown
brown
Earthing
conductor
Phase
Relay contact
Neutral
conductor
blue
blue
green/yellow
green/yellow
Connect the individual wires to the appropriate terminal.
Tighten screws.
Plug motion detector onto base and engage.
Connect motion detector to power supply.
Dismounting
Push
Using the screwdriver, carefully loosen the upper and lower
snap-ts and pull the device away in a forward direction.
Neutral
conductor
Earthing
conductor
3
Installation instructions
As the detector reacts to variations in temperature, avoid the
following situations:
Do not direct motion detectors at objects with highly-
reective surfaces such as mirrors, etc.
Do not install the motion detector near heat sources, such
as heating outlets, air conditioning systems, lamps, etc.
Do not direct the motion detector at objects that move in
the wind, such as curtains, large plants, etc.
Pay attention to the direction of motion during the test run.
10
20
30
40
40
10
20
30
40
40
10
20
30
40
40
3,0 m
5 m
16 m
220°
300°
6 m
10 m
32 m
Recommended installation height: 2 – 4 m
Transverse detection area: 16 m (transversal to the
detector)
Frontal detection area: 5 m (directly approaching the
detector)
Detection angle: 220° or 300°
6. Walking test and alignment
The walking test is used to test the detection area and to
restrict it if necessary.
Set the potentiometer time (min) to test.
The motion detector now only reacts to movements
(independent of brightness).
Walk through the detection area at a right angle. After the
motion detector has detected a movement, it switches on
for 2 s.
Pay attention to the direction of motion during the test.
10
D
10s
test
min
Align motion detector with sensor head
The sensor head can be turned by 45° downwards, 9
upwards, and 9 to the left and right.
45°
Left
90°
Right
90°
90°
7. Using cover clips
Use the supplied clips, to adjust the motion detector to the
desired detection area.
Remove the required section of the clips by using pliers or
the like.
Then place on the lens and screw it in.
When required, use the provided double sided adhesive
tape for fastening the cover clips.
8. Setting
The motion detector has 3 potentiometers for setting time
(min.), brightness (lux) and sensitivity (metres), etc.
12
16
6
4
mtr
300
5
lux
10
D
10s
test
min

Specyfikacje produktu

Marka: Theben
Kategoria: detektor ruchu
Model: TheLuxa P300 BK

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Theben TheLuxa P300 BK, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą