5020-0105 CO2ntrol Life - Operating Instructions
1. Green LED Display (<800ppm)
2. Yellow LED Display (800-1200ppm)
3. Red LED Display ( >1200ppm & buzzer alarm)
4. Mute Button
5. Power lnlet
6. Housing Stand
7. Screw Position
EMC/RFI
Readings may be affected if the uni! is operated within radio frequency electromagnetic eld strength of approximately 3 volts per meter, but the performance of
the instrument will not be permanently affected. Note: Under the electromagnetic eld of 3V/m, the reading will not meet the specication.
Product Overview
Thank you for selecting 5020-0105 desktop C0 2 monitor, 5020-0105 C02 monitor is smart, compact and easy-to-use. In addition to measuring the C0 2
concentration, 5020-0105 can also measure the ambient temperature and the relative humidity (CO 2+Temp.+RH). This product is developed to detect
the presence of C02 in ambient air and help people to take care of lndoor Air Quality. 5020-0105 can be widely used in the ofce building, school,
exhibition hall, shopping mall, meeting room, tness center, restaurant and other public places where personal comfort, healthy is important.
Features:
· Three different LED display shows the current lndoor Air Quality
· Press MUTE button for alarm on/off.
· Built in the LCD Backlight for easy reading in the dark.
Warnings:
· Please take off the AC power adapter and store it weil when this C0 2 monitor left idle for long.
· This C02 monitor is for harne use, not suitable for certifying the lest results.
· lf use this C02 monitor for testing, 5020-0105 does not guarantee the lest results.
1. 2 min. warm-up time when rst time power.
2. The LCD shows 4 bars with 1sec blank cycle during warm-up
3. The MUTE button is disabled during warm-up
4. The device shows the C02 readin after warm-u
Warm-Up Time: 2 MIN.
Press MUTE button to select buzzer on/off. lf the „MUTE“function is off, while C0 2
concentration exceed the alarm level (>1200 ppm), there will be a buzzer.
Note: The device settin with alarm is buzzer on when power on rst time, user can
set the alarm on/off under MUTE function
Usin the MUTE function:
Safety Instructions:
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning
and entire User Manual before using the product. These are important safety information and should be observed at all times.
1. Check if the contents of the package are undamaged and complete.
2. For cleaning the instrument please do not use an abrasive cleaner only a dry or moist piece of soft cloth. Do not allow any liquid into the interior
of the device.
3. Please store the measuring instrument in a dry and clean place.
4. Avoid any force like shocks or pressure to the instrument.
5. No responsibility is taken for irregular or incomplete measuring values and their results, the liability for subsequent damages is excluded!
6. Do not keep the product under the hol and moisture environment. Keep the product away from the heat source or near water.
7. Please use only the included power adaptor. lmproper power adaptor or power sources can cause serious damage to the product, or result in injury
or death to the user.
!
Technical changes, any errors and misprints reserved ● Reproduction is prohibited in whole or part
● Stand07 2104CHB ● © DOSTMANN electronic GmbH
Caring for poduct
To ensure you receive the maximum benet from using this product, please observe the follow guidelines.
1 Cleaning: Disconnect the power before clean- Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair: Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualied repairman if the
product needs servicing.
3. Air circulation: The vents allow the air circulation liquid for measurement of the CO 2 concentration and the ventilation should not be blocked.
Specicationen:
Method - NDIR · Display - LCD · Independent CO 2, RH and Temperature
readings · Sample Method - Diffusion or ow through (50 200 ml/min)~
CO2 Specication
Measurement Range: 0-3000ppm display
Display Resolution: 1ppm (0~1000ppm ); 5ppm (1001~2000ppm);
10ppm (2001~3000ppm)
Repeatability ± 20ppm @ 400ppm
Response Time: About 2 min for 63% step change
Warm-up Time: 2 min. at 22°C
Zone LED Display: Green: <800ppm; yellow: 800~1200ppm; Red >1200ppm
Temperature Specication:
Temperature Range: 0°C to 50°C display
Display Resolution: 0.1°C
Display Unit: °C
Response Time: 20-30 minutes (case must equalize with environment)
RH Specication:
Measurement Range: 20-90% RH
Display Resolution: 1% RH
Response Time: < 5Minuten for 63% step change
Operating Conditions:
Operating Temperature: 0°C - 50°C
Humidity Range:: 0 ~ 95% RH non-condensing
Storage Temperature: -20°C - 60°C
Power consumption:
Power supply: USB or 5 VDC from external AC/DC-adapter
which is included in package
(Use specied AC adapter only)
Input: AC 100~240V , 50/60HZ , 0.2A
Output: DC 5.0V , 1.0 A , 5.0W
Average active efciency: 74.926%
Noload power consumption: 0.0343W
Dimension:
Fault Codes & Troubleshooting Guede:
Fault Icon: Description of the fault: Suggested Actions:
The ambient temperature has exceeded the This error will clear when the temperature returns to the
operating temperature range (0...50°C) range between 0...50°C.
EEPROM System Problem Please reconnect AC adapter to 5020-0105 CO2 Monitor.
If the „Err5, Err6“ still appears, please contact the Service
Department for further assistance.
Waste disposal
This instrument is labelled in accordance with the EU Waste Electrical
and Electronic Equipment Directive (WEEE). Please do not dispose
of this instrument in household waste. The user is obligated to take
end-of-life devices to a designated collection point for the disposal of
electrical and electronic equipment, in order to ensure
environmentally-compatible disposal.
Explanation of symbols
This sign certies that the product meets the requirements of the EEC
directive and has been tested according to the specied test methods.
DOSTMANN electronic GmbH ● Mess- und Steuertechnik ● Waldenbergweg 3b ● D-97877 Wertheim-Reicholzheim Germany
Phone:+49 (0) 93 42 / 3 08 90 ● E-Mail: info@dostmann-electronic.de www.dostmann-electronic.de ●
Specyfikacje produktu
Marka: | TFA |
Kategoria: | multimetr |
Model: | AirCO2ntrol Life 31.5003 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z TFA AirCO2ntrol Life 31.5003, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr TFA
1 Października 2024
4 Września 2024
1 Września 2024
25 Sierpnia 2024
15 Sierpnia 2024
6 Lipca 2024
Instrukcje multimetr
- multimetr PeakTech
- multimetr Joy-It
- multimetr Voltcraft
- multimetr Milwaukee
- multimetr GW Instek
- multimetr Stanley
- multimetr Silverline
- multimetr Testo
- multimetr Aim TTi
- multimetr Chauvin Arnoux
- multimetr Gembird
- multimetr Uni-T
- multimetr Owon
- multimetr Biltema
- multimetr Digitus
- multimetr Vimar
- multimetr Schneider
- multimetr Emos
- multimetr Sonel
- multimetr BaseTech
- multimetr Perel
- multimetr Trotec
- multimetr Velleman
- multimetr Pyle
- multimetr Gossen Metrawatt
- multimetr Fluke
- multimetr Megger
- multimetr Weidmüller
- multimetr BENNING
- multimetr Brandson
- multimetr Metrix
- multimetr Rigol
- multimetr Abus
- multimetr Elro
- multimetr Ferm
- multimetr Hager
- multimetr Extech
- multimetr Testboy
- multimetr Kyoritsu
- multimetr Klein Tools
- multimetr Powerfix
- multimetr Workzone
- multimetr Alecto
- multimetr JUNG
- multimetr Monacor
- multimetr Etekcity
- multimetr Wiha
- multimetr HT Instruments
- multimetr Qian
- multimetr Beha-Amprobe
- multimetr Clas Ohlson
- multimetr Laserliner
- multimetr Ideal
- multimetr Profile
- multimetr Aldi
- multimetr Appa
- multimetr Amprobe
- multimetr Amiko
- multimetr Brennenstuhl
- multimetr Tacklife
- multimetr Somogyi
- multimetr Steren
- multimetr Flir
- multimetr Maxwell
- multimetr Topcraft
- multimetr Altai
- multimetr Plieger
- multimetr Projecta
- multimetr Cablexpert
- multimetr Greenlee
- multimetr Högert
- multimetr Wago
- multimetr REV
- multimetr Bruder Mannesmann
- multimetr Keithley
- multimetr Bearware
- multimetr Metrel
- multimetr Multimetrix
- multimetr Digi-tool
- multimetr Skandia
- multimetr Elma
- multimetr Testec
- multimetr Hubinont
- multimetr Kewtech
- multimetr Strex
- multimetr Mastech
- multimetr MBS
- multimetr MGL Avionics
- multimetr PCE Instruments
- multimetr Micronta
- multimetr CEM
- multimetr Horex
- multimetr Cosinus
- multimetr Kurth Electronic
- multimetr IWH
- multimetr Weltron
- multimetr Sanwa
- multimetr Rohde & Schwarz
- multimetr EEVBlog
- multimetr Kingcraft
- multimetr Caltek
- multimetr Elworks
- multimetr Noyafa
Najnowsze instrukcje dla multimetr
14 Stycznia 2025
12 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
10 Stycznia 2025
8 Stycznia 2025
2 Stycznia 2025
31 Grudnia 2025