Instrukcja obsługi Tesy BelliSlimo Cloud 100
Tesy
Kotły i bojlery
BelliSlimo Cloud 100
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tesy BelliSlimo Cloud 100 (33 stron) w kategorii Kotły i bojlery. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/33
BG
БОЙЛЕР ЕЛЕКТРИЧЕСКИ
2-5
Инструкция за употреба и съхранение
EN
ELECTRIC WATER HEATER
6-9
Instructions for use and storage
RU
ЭЛЕКТРИЧЕСКИЙ ВОДОНАГРЕВАТЕЛЬ
10-13
Инструкция для употребления и сохранения
ES
TERMO DE AGUA ELÉCTRICO
14-17
Instrucciones de uso y almacenamiento
PT
CALENTADOR DE AQUA ELÉCTRICO
18-21
Manual de instruções para uso e conservação
DE
ELEKTRISCHER WARMWASSERSPEICHER
22-25
Bedienungs- und Aufbewahrungsanleitung
IT
SCALDABAGNI ELECTTRICI
26-29
Manuale d'uso e stoccaggio
RO
BOILER ELECTRIC
30-33
Instrucţiuni de utilizare şi depozitare
PL
POGRZEWACZE ELEKTRYCZNE
34-37
Instrukcja obsługi, użytkowania i przechowywania
CZ
ELEKTRICKÝ OHŘÍVAČ VODY
38-41
Návod na použití a uchování výrobku
RS
ELEKTRIČNI BOJLER
42-45
Упутства за употребу и складиштење
www. tesy.com
HR
ELEKTRIČNE GRIJALICE VODE
46-49
Upute za uporabu i skladištenje
UA
ВОДОНАГРІВАЧ ПОБУТОВИЙ ЕЛЕКТРИЧНИЙ
50-53
Інструкція для використання і зберігання
SI
ELEKTRIČNI GRELNIK VODE
54-57
Navodila za uporabo in shranjevanje
SK
ELEKTRICKÝ OHRIEVAČ VODY
58-61
Návod na použitie a uskladnenie
LT
ELEKTRINIS VANDENS ŠILDYTUVAS
62-65
Naudojimo ir saugojimo instrukcija
LV
ELEKTRISKAIS ŪDENS SILDĪTĀJS
66-69
Lietošanas un uzglabāšanas instrukcija
EE
ELEKTRILINE VEESOOJENDAJA
70-73
Paigaldus ja kasutusjuhend
GR
ΗΛΕΚΤΡΙΚO ΘΕΡΜΟΣΙΦΩΝΟ
74-77
Οδηγίες χρήσης και αποθήκευσης
FR
CHAUFFEEAU ÉLECTRIQUE
78-81
Manuel d'utilisation et de stockage
MK
КОТЕЛ ЕЛЕКТРИЧНИ
82-85
Упатство за користење и складирање
NL
ELEKTRISCHE BOILER
86-89
Aaanwijzingen voor gebruik en opslag
AL
BOJLERIT ELEKTRIK
90-93
Instruksioni për shfrytězimin
6
EN I. IMPORTANT RULES
1. This technical description and instructions manual was prepared in order to acquaint you with the product and the conditions of proper
installation and use. These instructions were also intended for use by qualied technicians, who shall perform the initial installation, or
disassembly and repairs in the event of a breakdown.
2. Following the current instructions will primarily be of interest to the consumer, but along with this, it is also one of the warranty conditions,
pointed out in the warranty card, so that the consumer can benet from the free warranty services. The producer is not responsible for damages
in the appliance that have appeared as a result of operation and/or installation not corresponding to the instructions here.
3. The electric water heater complies with the requirements of
EN 60335-1, EN 60335-2-21.
4. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved.
5. Children shall not play with the appliance.
6. Cleaning and user maintenance shall not be made by children without supervision.
Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may cause
grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and connection of the
appliance may also lead to damage to the consumers’ property /damage and/ or destruction/, or to that of third persons, as a result of, but not limited to
ooding, explosion and/or re.
Installation, connection to the main water and power supply, and putting into operation must be carried out by certied electricians and technical personnel certied
in installation of this category of appliances, who have obtained their license in the state where the installation and commissioning of the appliance are carried out,
and in compliance with its local legislation.
All alterations and modications to the water heater’s construction and electrical circuitry are forbidden. If such alterations or modications are established
during inspection, the appliance’s warranty shall be null and void. Alterations and modications shall mean each instances of removal of elements
incorporated by the manufacturer, building in of additional components into the water heater, replacement of elements by similar elements unapproved by the
manufacturer.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Mounting
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1. The water heater must only be mounted in premises with normal re resistance.
2. In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead
or portable showerhead attachment.
3. The water heater is designed to operate only in closed and heated premises where the temperature is not lower than 4°C and it is not designed
to operate in a continuous protracted regime.
4. When mounted on a wall - the device is suspended by means of the M8 bolts attached to the housing, which are installed on brackets pre-mounted and
levelled with the wall. The load-bearing brackets and dowels for wall mounting are included in the kit.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Water heater connection
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1. The appliance is intended to supply hot water to household sites equipped with a piping system working at pressure below 6 bar (0,6 Mpa).
2. .
The safety return-valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming
water’s direction. Additional stopcocks must not be mounted between the safety return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must
be bought additionally. For mechanisms operating in accordance with EN 1487 the announced operational pressure must be no more than 0.7 MPa. For other
protection valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance’s sign. In these cases the safety valve
which the appliance is supplied with should not be used.
3. The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining - its free end
must be always open to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.
4. In order to secure the water heater’s safe operation, the safety return-valve must undergo regular cleaning and inspections for normal
functioning /the valve must not be obstructed/, and for the regions with highly calcareous water it must be cleaned from the accumulated lime
scale. This service is not provided under warranty maintenance.
5. In order to prevent injury to user and third persons in the event of faults in the system for providing hot water, the appliance must be
mounted in premises outtted with oor hydro insulation and plumbing drainage. Don’t place objects, which are not waterproof under the
appliance under any circumstances. In the event of mounting the appliance in premises not outtted with oor hydro insulation, a protective
tub with a plumbing drainage must be placed under the appliance.
6. During operation – regime of heating the water – water drops through the drainage opening of the protection valve are usual. The protection
valve should be left open to the atmosphere. Measures should be taken to lead and collect the leakages in order to prevent damages.
7. If the probability exists for the premise’s temperature to fall below 0°С, the water heater must be drained.
In the event you must empty the water heater, rst you must cut o its power supply. The inow of water from the water mains must rst be
terminated and the hot water tap of the mixing-faucet must be opened. The water tap 7 (g 5) must be opened to drain the water from water
tank. If there is no such tap build in the pipe line, than the water can be drain directly from inlet pipe of water tank after when you disconnect it
from water main.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Connection to the electrical network
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
1. Do not switch on the water heater unless you established it was lled with water..
2. Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
3. Models without power cord
,
the circuit has to be supplied with a safety fuse (16A) and with inbuilt device to ensure disconnection of all pole pieces in
the conditions of over-voltage from category III
.
4. If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative or a person with similar
qualication, to avoid any risk.
5. Т
he power supply conductor insulation from xed wiring must be protected from direct contact with the ange (in zone under the plastic panel). For
example, insulating sleeving having temperature rating higher than 90 °C can be used
.
6. During the heating the appliance could produce a hissing noise (the boiling water). This is common and does not indicate any damage. The
noise gets higher with the time and the reason for this is the accumulation of limestone. To remove the noise the appliance must be cleaned from
limestone. This type of cleaning is not covered by the warranty.
Dear Clients,
The TESY team would like to congratulate you on your new purchase. We hope that your new appliance shall bring more comfort to your home.
9
EN
English
EC2 - ECO NIGHT (SMART algorithm with night-time heating priority).
The selected mode is displayed on the screen.
Attention! Your TESY electric water heater is of the highest energy class. The
class of the appliance is guaranteed only when it operates in mode “Eco ECO
Smart” due to the signicant energy savings that are generated.
In the "ECO" mode, the water heater produces its own algorithm to ensure
energy savings, respectively, to reduce your electricity bill, but to maintain
maximum comfort in use.
Principle of operation: after selecting one of the three Eco Smart modes, the
appliance will learn your habits and it will elaborate a weekly programme so
as to provide the necessary quantity of water in the respective time when you
need it and at the same time to save energy and thus to reduce your electricity
bill. This principle of operation requires a period of self-training which lasts a
week, and after that the Eco Smart mode begins to accumulate energy savings
without disturbing your comfort calculated on the basis of your studied habits.
The appliance continuously monitors your habits and continuously gets self-
trained.
In this mode it is impossible for you to intervene after it has been selected.
In case you often change your habits, the appliance will not be able to
elaborate an exact algorithm which to guarantee your comfort and to provide
you with hot water exactly when you need it. In this sense, if the operation of
the appliance in Eco Smart mode does not satisfy you and does not provide
you with the required comfort, and at the same time you want the appliance
to keep reducing your costs, by pressing the button you can select EC1
mode of operation – for higher level of comfort which again guarantees energy
saving, but to a lower extent. mode of operation is intended for users with EC1
frequently changing habits for whom an exact schedule of weekly operation
would be dicult to establish.
To generate maximum energy savings, you can select the mode. This is a EC2
SMART algorithm mode with overnight heating priority.
Note: When the power is turned o or o, the appliance keeps the settings for
up to 12 hours. You can restart the algorithm only by the On/O button, and
the appliance will begin its self-training again.
•"LOCK" function
By holding buttons + simultaneously, the control panel locks itself and
no commands may be given through it. If the panel is locked, the symbol
is visualized on the display. If you press a certain symbol while the panel is
locked, all buttons light up but the appliance does not accept commands and
the symbol ashes 3 times, prompting for unlocking. To unlock the panel
once again, you need to press and hold buttons + simultaneously for
2 seconds.
•"Vacation" mode
If you plan to be away from home for more than a day, you can enable the
Vacation mode, so that the electric water heater will “know” when you will be
back to provide you with hot water.
To turn the Vacation mode on, you need to press button . The display
visualizes „00“ days and the digits and symbol are ashing. If the “00”
number of days is not changed, the Vacation mode cannot be activated.
To introduce the number of days, use the button. If you touch it once, the
counter value is increased by one. If you press and hold the button, the counter
value increases automatically at a higher pace. The maximum number of days
you can set, is 90. The symbol is still blinking. The other two parameters
are set as default settings: maximum number of showers at 18:00 on the last
vacation day.
To change the time, at which you will need the desired amount of hot water,
use the button. To change the number of showers, use the button.
The parameters set are conrmed by pressing the button, thus activating
the Vacation mode. On the display the symbol stops blinking and is lit
constantly. The number of vacation days, the number of showers and the time
when hot water needs to be available, are visualized.
To exit the vacation mode without changes, you may either press or, if you
do not touch any button for a long time. The symbol disappears.
To exit the Vacation mode, press any of the following buttons: , or
. If you press , while the Vacation mode is activated, you enter the
programming mode and the number of days and the symbol start blinking
again.
The number of days that you enter (the period of your absence) must
include the day on which you will be coming back home.
•"BOOST" function (a one-time heating up to maximum temperature and
automatic return to the already selected mode of operation)
When the BOOST function is enabled the water heater will heat the water up to
max °C without changing the algorithm of operation of the respective mode of
operation. When the maximum temperature has been reached the appliance
automatically switches to the previously selected mode of operation. The
BOOST function is active with the following modes: Eco Smart, Vacation and
Weekly Programmer.
To enable the BOOST function, press continuously (for about 3 seconds) the .
To deactivate BOOST, hold the button once again.
•"RESTORE FACTORY SETTINGS" function
To enable this function, the appliance must be in Stand-by mode. You can
enable it by pressing and holding the button for at least 10 seconds. All
symbols on the display will be illuminated which will indicate that you have
restored the factory settings of the appliance.
•"Shower" symbol
The Handset symbol provides you with information on the amount of
hot water that has already been heated and whether the amount set has been
reached in the dierent modes. The amount of water per shower is calculated
on the basis of the average European standards and it may not coincide with
your personal comfort.
When the "Handset" symbol is lit constantly, it means that the set amount of
hot water is reached. When the "Handset" symbol ashes, this indicates that the
appliance is in a warm-up mode. When more than one "showers" are not ready,
they icker one after another continuously. Thus you obtain information about
the set amount of hot water and the amount reached at any given time.
Example:
Hot water for 2 showers is ready to use. The third shower is in the process of heating.
The nal objective is to have hot water equivalent to 3 showers.
In the “Manual control” mode and the “BOOST” mode the screen visualizes a
timer counting the estimate time remaining until the set amount of hot water
is reached.
•Problem log
Code of
error Name of error
Еr1 Sensor 1 – The lower sensor is switched o
Еr2 Sensor 1 - The lower sensor is in short circuit
Еr3 Sensor 1 – The upper sensor is switched o
Еr4 Sensor 1 - The upper sensor is in short circuit
Еr5 Sensor 2 – The lower sensor is switched o
Еr6 Sensor 2 - The upper sensor is in short circuit
Еr7 Sensor 2 – The lower sensor is switched o
Еr8 Sensor 2 - The upper sensor is in short circuit
Еr9 Software error
Еr10 The water heater is turned on without any water present (H1)
Еr11 The water heater is turned on without any water present (H2)
Note: If you see the symbol and any of the above listed errors, please
contact an authorized service centre. You can nd a list of them in the
warranty card.
VII. PERIODIC MAINTENANCE
In the conditions of normal use of the water heater, under the inuence
of high temperature, limestone (the so-called lime scale) deposits on the
surface of the heating element. This worsens the heat exchange between the
heating element and the water. The temperature on the surface of the heating
element and around it increases. Specic noise can be heard – of boiling
water. The thermoregulator begins to switch on and o more frequently. A
“deceptive” activation of the thermal protection is possible. Due to these
facts, the manufacturer recommends preventive maintenance of your water
heater every two years by an authorized service centre or service facility, this
service remaining at the customer’s expense. This preventive maintenance
should include cleaning and examination of the anode protector (for water
heaters with glass-ceramic coating), which has to be replaced with a new one,
if necessary.
To clean the appliance, use a damp cloth. Do not use abrasive or solvent-
containing detergents.
The manufacturer does not bear responsibility for any consequences
arising from non-adherence to these instructions.
Instructions for protection of the environment
Old electric appliances contain valuable materials and must not be
disposed of with the domestic waste! Please contribute actively for
the protection of the resources and the environment and dispose
of the appliance in the buy-back centres organized for this purpose
(if such are available).
Specyfikacje produktu
Marka: | Tesy |
Kategoria: | Kotły i bojlery |
Model: | BelliSlimo Cloud 100 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tesy BelliSlimo Cloud 100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kotły i bojlery Tesy
20 Września 2024
20 Września 2024
17 Września 2024
17 Września 2024
11 Września 2024
9 Września 2024
8 Września 2024
5 Września 2024
5 Września 2024
27 Sierpnia 2024
Instrukcje Kotły i bojlery
- Kotły i bojlery Electrolux
- Kotły i bojlery AEG
- Kotły i bojlery Teka
- Kotły i bojlery Gorenje
- Kotły i bojlery LERAN
- Kotły i bojlery Philips
- Kotły i bojlery Morco
- Kotły i bojlery Dometic
- Kotły i bojlery Bosch
- Kotły i bojlery Whirlpool
- Kotły i bojlery Ferroli
- Kotły i bojlery Midea
- Kotły i bojlery Hisense
- Kotły i bojlery Infiniton
- Kotły i bojlery Panasonic
- Kotły i bojlery Rinnai
- Kotły i bojlery GE
- Kotły i bojlery Taurus
- Kotły i bojlery Orbegozo
- Kotły i bojlery Siemens
- Kotły i bojlery Haier
- Kotły i bojlery Jocel
- Kotły i bojlery Remeha
- Kotły i bojlery Truma
- Kotły i bojlery CATA
- Kotły i bojlery Hotpoint
- Kotły i bojlery Ariston Thermo
- Kotły i bojlery Intergas
- Kotły i bojlery Daikin
- Kotły i bojlery Kospel
- Kotły i bojlery Buderus
- Kotły i bojlery Corbero
- Kotły i bojlery Viessmann
- Kotły i bojlery Fagor
- Kotły i bojlery Vaillant
- Kotły i bojlery Waeco
- Kotły i bojlery Eta
- Kotły i bojlery HTW
- Kotły i bojlery Dimplex
- Kotły i bojlery Baxi
- Kotły i bojlery Arçelik
- Kotły i bojlery Worcester
- Kotły i bojlery Atag
- Kotły i bojlery Rommer
- Kotły i bojlery Inventum
- Kotły i bojlery SVAN
- Kotły i bojlery Solac
- Kotły i bojlery Mora
- Kotły i bojlery VOX
- Kotły i bojlery Junkers
- Kotły i bojlery ACV
- Kotły i bojlery Aspes
- Kotły i bojlery Hitachi
- Kotły i bojlery Respekta
- Kotły i bojlery Technika
- Kotły i bojlery Quantum
- Kotły i bojlery Kelvinator
- Kotły i bojlery Sencor
- Kotły i bojlery Kunft
- Kotły i bojlery Guzzanti
- Kotły i bojlery De Dietrich
- Kotły i bojlery Nefit
- Kotły i bojlery A.O. Smith
- Kotły i bojlery Stiebel Eltron
- Kotły i bojlery Elco
- Kotły i bojlery Masterwatt
- Kotły i bojlery Nibe
- Kotły i bojlery Elba
- Kotły i bojlery Buffalo
- Kotły i bojlery TTulpe
- Kotły i bojlery Atlantic
- Kotły i bojlery Plieger
- Kotły i bojlery Bulex
- Kotły i bojlery AWB
- Kotły i bojlery Quooker
- Kotły i bojlery OSO
- Kotły i bojlery La Nordica
- Kotły i bojlery Clage
- Kotły i bojlery Noveen
- Kotły i bojlery Joven
- Kotły i bojlery Daalderop
- Kotły i bojlery Fakir
- Kotły i bojlery Cointra
- Kotły i bojlery Eccotemp
- Kotły i bojlery Biasi
- Kotły i bojlery Thermor
- Kotły i bojlery Sentry
- Kotły i bojlery Burco
- Kotły i bojlery Khind
- Kotły i bojlery LEMET
- Kotły i bojlery Duwaco
- Kotły i bojlery Wagaparts
- Kotły i bojlery SolarEdge
- Kotły i bojlery IQE
- Kotły i bojlery Wahlbach
- Kotły i bojlery Ygnis
- Kotły i bojlery Dux
- Kotły i bojlery Intellihot
- Kotły i bojlery Airthereal
- Kotły i bojlery Thermoflow
- Kotły i bojlery IStore
- Kotły i bojlery Apricus
- Kotły i bojlery Aquamarin
- Kotły i bojlery Sime
- Kotły i bojlery Hydrotherm
- Kotły i bojlery Amtrol
- Kotły i bojlery Neopower
- Kotły i bojlery Gleamous
- Kotły i bojlery AquaMAX
- Kotły i bojlery My-PV
- Kotły i bojlery EvoHeat
- Kotły i bojlery Rheem
- Kotły i bojlery Solahart
- Kotły i bojlery ENEFT
- Kotły i bojlery Imarflex
- Kotły i bojlery MicroHeat
- Kotły i bojlery Noritz
Najnowsze instrukcje dla Kotły i bojlery
14 Października 2024
13 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024