Instrukcja obsługi TCL TAC-12CHSA


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla TCL TAC-12CHSA (30 stron) w kategorii Klimatyzator - Chłodnica powietrza. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/30
WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
CONTENTS
1. IMPORTANT NOTICE ···································2
2. TECHNICAL SPECIFICATION ·····················3
3. OPERATION DETAILS ·······························5
4. WIRING DIAGRAM ············· 13
5. EXPLOSION VIEW ····························17
6. PARTS LIST ·············22
Models
TAC-07CHSA/R TAC-09CHSA/R
TAC-12CHSA/R TAC-18CHSA/R
TAC-24CHSA/R
OB207t-1qxp 25/9/97 8:51 PM Page 1
TCL
SERVICE MANUAL
No.TE040918
Downloaded from AC-Manual.com Manuals
IMPORTANT NOTICE
This service manual is intended for use by individuals possessing adequate
backgrounds of electrical, electronic and mechanical experience. Any
attempt to repair the appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any liability in
connection with its use.
The information, specifications and parameter are subject to change due to
technical modification or improvement without any prior notice. The
accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please furnish the
following information:
1. Model No. with Indoor or Outdoor
2. No. in the Explosion View
3. Part Name
4. The quantity you ordered
TCL Air Conditioner Service ManualTCL Air Conditioner Service ManualTCL Air Conditioner Service Manual
TCL Air Conditioner Service Manual
2
Downloaded from AC-Manual.com Manuals
TCL Air Conditioner Service Manual
3
Technical Specifications
Model No. TAC-07CHSA/R TAC-09CHSA/R TAC-12CHSA/R TAC-18CHSA/R
Type Heat Pump Heat Pump Heat Pump Heat Pump
Control type Remote Remote Remote Remote
Rated cooling capacity Btu/h 7000 9000 12000 18000
Rated heating capacity Btu/h 7700 9500 12500 19000
EER for cooling Btu/h.w 10.4 10.4 10.5 10.27
COP for heating W/W 3.49 3.49 3.21 3.37
Moisture removal Liters/h 0.8 0.8 1.0 1.0
High dB(A) 36 36 38 36
Med. dB(A) 32 32 34 32
Indoor noise level at
cooling Low dB(A) 29 29 32 29
Outdoor noise level dB(A) 55 55 55 55
Electrical Data
Power supply 220V~/50Hz
Voltage Range V
Cooling A 3.0 3.9 5.2 8.0
Rated current Heating A 2.9 3.6 5.2 7.5
Cooling W 670 850 1140 1750
Rated input Heating W 630 790 1140 1650
Refrigerating System
Refrigerant/Charge Gram R410A/480g R410A/480g R410A/730g R410A/1400g
Type Rotary Rotary Rotary Rotary
Model ---- ---- ---- ----
LRA A ---- ---- ---- ----
Compressor
MFG ----
---- ---- ----
Evaporator Louver fin and grooved tube type (
ϕ
7)
Condenser Corrugated fin and grooved tube type (
ϕ
9.52)
Expansion device Capillary tube
Defrosting system Microcomputer controlled reverse system
Fan System
Indoor air circulation/Hi Cooling m3/h 430 430 530 800
Indoor fan type Cross flow Cross flow Cross flow Cross flow
Cooling rpm 1150/1050/950 1150/1050/950 1270/1170/1000 1060/970/880
Heating rpm 1150/1050/950 1150/1050/950 1250/1150/1000 1060/970/880
Dry rpm 950 950 950 880
Indoor fan speed
H/M/L Sleep rpm 950 950 950 880
Indoor fan motor output W 12 12 12 22
Outdoor air circulation m3/h
Outdoor fan type Propeller fan Propeller fan Propeller fan Propeller fan
Outdoor fan speed rpm 895 860 860 850
Outdoor fan motor output W 25 31 31 45
Connections
Refrigerant coupling Flare type
Gas Inches 3/8 3/8 1/2 1/2
Connecting Pipe Liquid Inches 1/4 1/4 1/4 1/4
Connecting Wiring Size x Core number
Drainage Pipe O.D 16mm
Others
Suitable area m2 9~15 12~19 16~28 30~40
Indoor mm 710x240x179 710x240x179 770x240x179 1033x313x202 Net dimensions
(W x H x D) Outdoor mm 600x232x500 700x255x540 760x252x552 760x252x552
Indoor kg 8 8 8 14
Net weight Outdoor kg 25 26 32 43
Indoor mm 805x325x270 790x310x252 863x325x270 1088x380x263 Packing dimensions
(W x H x D) Outdoor mm 745x352x542 803x380x595 863x405x605 838x361x600
Indoor kg 10 10 10 19
Gross weight Outdoor kg 28 34 34 45
Loading Capacity 40’/40’HC 132/280/318 111/238/276 106/236/248 90/188/218
Downloaded from AC-Manual.com Manuals


Specyfikacje produktu

Marka: TCL
Kategoria: Klimatyzator - Chłodnica powietrza
Model: TAC-12CHSA

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z TCL TAC-12CHSA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Klimatyzator - Chłodnica powietrza TCL

TCL

TCL TAC-12CHSA Instrukcja

23 Września 2024

Instrukcje Klimatyzator - Chłodnica powietrza

Najnowsze instrukcje dla Klimatyzator - Chłodnica powietrza