Instrukcja obsługi Tarkett Woodstock 832

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tarkett Woodstock 832 (12 stron) w kategorii Podłogi laminowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
L AM I N AT E
Install it, live it, care for it!
Preparation
1 - Storage and handling
nPallets shall not be stacked more than five high.
nCartons of laminate must be stored horizontally
at all times.
nStorage area shall be climate-controlled with
a temperature not less than 18ºC. (65ºF.).
nProtect carton corners from damage.
nDo not puncture plastic wrapping.
2 - Tools and materials and accessories
nVacuum cleaner
nSafety Glasses
n8 mm (5/16”)
Spacers(Art. Nb.:
8022000
)
Alternatively: installation springs
(Art. Nb.:
8265000
)
nT-square
nTape Measure
nSaws - Table Saw
(fine tooth carbide tipped blade)
Miter Saw/Jig Saw/Circular Saw.
nFoam Underlayment
Tarkettfoam
A recyclable, freon-free 2 mm foam:
- to level slight undulations & bumps
of the subfloor
- to reduce impact noise 19 dB with
7 mm products
Dimensions: 1 m x 20 m = 20 m2
art. Nb:
8021000
Thickness 2 mm
Contents Recyclable
polyethylene
Composicion Freon free
Properties Reduces impact noise: Levels slight
undulations of the subfloor
Before laying Support must be clean and dry
Laying Buttin edgg es (never overlap)
Do not glue or fix
The 3 mm Soundblockfoam (Combi foam with vapor retarder)
All-in-one underlayer: recyclable, freon-free, insulator
3 mm PE foam (closed cell structure) with 2 extra layers
offering a genuine vapour barrier.
- Gliding top-layer for a handier fitting of the planks.
- Foam to level out slight bumps, improve the shock-&-
pressure resistance of the flooring & noise insulation.
- Bottom layer for an optimal damp resistance
with 20 cm spare length.
Dimensions: 1,2 m x 16,7 m = 20 m
2
Art. nb:
8267000
Foam PE with closed cell structure
0.03 mm + 0.07 mm layers
Environment 100% recyclable Freon free
Before laying Support must be clean
and dry
Laying see drawing
Storage Ventilated room
NOTE: use only Tarkett® underlayers with
Tarkett® Laminate flooring. Guaranty is void
if any other underlayers are used.
Installation instructions
1,20 m
1,40 m
Spacer
Spring
Good to know:
Use Tarkett® 2 mm Foam over a
PE-plastic foil (vapor retarder) or use
Tarkett® 3 mm SoundBlock combi-foam.
Tarkett® 3 mm SoundBlockfoam
combines PE foil and foam for damp
& sound proofing.
A 0.2 mm PE foil is thus not necessary.
2
3 - Subfloor requirements
Tarkett® Laminate Flooring may be installed over most
types of subfloors and existing floors on all grade levels.
nAll substrates must be structurally sound and free
from movement.
nThe substrate must be clean, dry, level and free
of any defects.
Dry? The sub floor must be dry. Measure & file always
with adequate test instruments.
Moisture content limits: moisture content of cement
screed/concrete must be < 2% CM (CM method ) and of
anhydrite cement floors (Calcium sulphate screed) < 0.5% CM.
Level? The subfloor must be levelled within 3 mm in 1 m
-1/4” in 8 ft.- (DIN 18202 Zeile 4) or 2 mm over 2 m.
Smooth and level all irregularities with a hydraulic
(portland) cement base patching and leveling compound.
Free of any defect? Cross check old wood floors,
nail/screw to eliminate squeaking. Brush or vacuum
clean your floor - work clean!
nTarket Laminate Flooring is not recommended for
use in high humidity areas where the floor is usually
wet. (steam rooms, saunas).
Concrete
nConcrete subfloors shall be properly cured and
allowed to dry for at minimum of 90 days before
installation.
Wood
nSuspended wood subfloors shall have a minimum
45 cm (18”) of well-ventilated air space clearance
above the ground.
nA moisture vapor retarder shall not be installed over
wooden floor/construction.
nMoisture content of wood subfloor shall not exceed 12%.
Existing Sheet and Tile Flooring
nExisting flooring must be fully adhered and in good
condition.
nExisting floor must be a single layer.
nRepair any damaged areas.
Carpeting
nDeep pile carpeting and padding must be removed
before laying laminate flooring.
nTarket Laminate Flooring may be installed over
industrial direct glue carpeting (no padding) that
is installed over wood subfloors only.
nCarpetin emg must be r oved if installed over concrete.
nUse of a foam underlayment is not recommended over
carpet.
IMPORTANT ! A min. 0.2 mm ageing resistant damp-proof
PE foil shall be installed over all sub floors, except over
wooden floor/construction. Overlap seam edges 20 cm
min an tape end tir lene gth o seam with duct tape.f
Good to know:
Laminate and under floor heating
Due to the hydroscopic properties of a laminated floor containing more than 90% wood the working
environment should display the following values before, during and after laying: floor surface
temperature min. 15°C (59°F); air temperature 18 - 24°C (64.4 - 75.2°F); relative humidity
40 - 70 %. The floor will look its best under these conditions. If the values for relative humidity
lie outside the above range the boards may become irreversibly warped. A damp proofing layer
must always be laid! If flooring is to be laid on top of under floor heating there is a specific heating
procedur e (in accordance to DIN 4725) to be followed before the damp proofing layer is put in place.
Explanations and restrictions:
Laminate flooring is suitable for installation on top of underfloor heating systems provided that the heating element is embedded
into concrete or any other sub floor. Laminate flooring is not suitable for installation on top of underfloor heating foil installed
on top of concrete or any other sub floor unless otherwise specified by the underfloor heating manufacturer. Surface temperature
should never exceed 28°C. Standard electrical underfloor heating foil systems can usually reach a surface temperature of more
than 28°C when turned up at maximum running temperature, which makes them not suitable as sub floors for laminate flooring.
Procedure:
Installing laminate flooring on top of low temperature under-floor heating is possible provided that a specific heating procedure
(in accordance to DIN 4725 & regardless of the season) is followed before the damp proofing layer is put in place:
set the temperature of your heating device at 25°C & let it run for 3 days. Increase your heating in steps of 5°C
up to its max. temperature. Let it run continuously for 72 hours.
Decrease the temperatur e in steps of 10°C until reaching a floor surface temperature of 18°C. Before, during &
at least 3 days after the installation of your flooring, the floor surface temperature should be maintained at 18°C.
Do not forget to install the 0.2 mm vapour barrier! After the course of 3 days, the temperature should be slowly
raised to the required operatin g temperature . The surface temperature of the heated sub floor should never
exceed 28°C. Please check with your dealer & the floor heating system producer.
3
e