Instrukcja obsługi Sylvania SRM910-33ECN


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Sylvania SRM910-33ECN (6 stron) w kategorii Otwarte palenisko. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/6
1
ElEctric FirEplacE HEatEr
Model: SRM910-33ECN
iMpOrtaNt: plEasE NOtE wHEN yOu OpEN tHE cartON carEFully
cHEck tHE uNit aNd MakE surE tHErE is NO daMagE. iF yOu
HavE aNy prOblEMs witH assEMbliNg tHE uNit, witH HOw tHE
variOus FuNctiONs wOrk Or witH daMagE Or MissiNg parts
plEasE call 1-800-459-4409 (Est) iMMEdiatEly FOr sErvicE.
NOtE:
dO NOt rEturN uNit tO tHE stOrE bEFOrE calliNg tHE tOll FrEE
NuMbEr.
Do not dispose of your cartons until you are completely satisfied with your new
fireplace heater.
NOTE: Light bulbs may become loose during shipping. If the flame effect is dim or
does not work, please check that light bulb or bulbs are finger tight in socket. See
instructions for replacing bulb or bulbs.
INSTRUCTION MANUAL
attENtiON:
1. Find a location for the fireplace heater that is protected from direct sunlight.
2. Do not plug the unit into the power outlet before reading all instructions.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
IMPORTANT SAFETY
INSTRUCTIONS
wHEN usiNg ElEctrical appliaNcEs, basic prEcautiONs sHOuld
always bE FOllOwEd tO rEducE tHE risk OF FirE, ElEctric sHOck,
aNd iNJury tO pErsONs, iNcludiNg tHE FOllOwiNg:
1) Read all instructions before using this electric fireplace heater.
2) This electric fireplace heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. The grill directly in front of the heater outlet becomes
hot during heater operation. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) away from
the front of the unit and keep them away from the sides and rear.
3) Extreme caution is necessary when any heater is used by, or near, children or
individuals with disabilities and whenever the fireplace is left operating
and unattended.
4) Always unplug fireplace when not in use.
5) Do not operate any electric fireplace with a damaged cord or plug or after the
heater malfunctions, has been dropped or damaged in any manner.
6) Do not use outdoors.
7) This electric fireplace heater is not intended for use in bathrooms, laundry
areas and similar indoor locations. Never locate heater where it may fall into a
bathtub or other water container.
8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or
similar coverings. Arrange cord away from traffic area and where it will not be
tripped over.
9) To disconnect fireplace, turn controls to off, then remove plug from outlet.
10) Connect to properly grounded outlets only.
11) Do not insert or allow foreign objects to enter any ventilation or exhaust open-
ing as this may cause an electric shock or fire, or damage the heater.
12) To prevent a possible fire, do not block air intakes or exhaust in any manner. Do
not use on soft surfaces, like a bed, where openings may become blocked.
13) A heater has hot and arcing or sparking parts inside. Do not use it in areas
where gasoline, paint, or flammable liquids are used or stored.
14) Use this fireplace heater only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock, or injury to
persons.
15) Avoid the use of an extension cord because the extension cord may overheat
and cause a risk of fire. However, if you have to use an extension cord, the cord
shall be No.16AWG minimum size and rated not less than 1875 watts.
16) Caution: Do not plug this product into a receptacle controlled by a wall switch
or dimmer.
17) When storing or transporting the unit and cord, keep in a dry place, free from
excessive vibration and store so as to avoid damage.
cautiON:
iF yOu usE tHis HEatEr iN cONJuNctiON witH a tHErMal cONtrOl, a
prOgraM cONtrOllEr, a tiMEr Or aNy OtHEr dEvicE tHat switcHEs
tHE HEatEr ON autOMatically, rEMEMbEr tO ObsErvE all saFEty
warNiNgs at all tiMEs. tHE FirEplacE HEatEr Has saFEty OvErHEat
prOtEctiON. iF tHE OvErHEat prOtEctiON trips, switcH OFF all
switcH buttONs aNd wait apprOxiMatEly 5 -10 MiNutEs. it sHOuld
rEsEt autOMatically ONcE tHE uNit cOOls dOwN.
warNiNg:
Procedures and techniques if not carefully followed will result in damage to the
equipment and will expose the user to the risk of serious injury, illness or death.
This electric fireplace heater is for use on 120 volts. The cord has a plug as shown
at A in illustration below. An adapter as shown at C is available for connecting
three-blade grounding-type plugs to two-slot receptacles. The green grounding
plug extending from the adapter must be connected to a permanent ground such
as a properly grounded outlet box. The adapter should not be used if a three-slot
grounded receptacle is available.
A 15 AMP circuit is required to operate this heater. If the breaker trips when the
heater is used then you may need to move the heater to another location or unplug
other appliances that are on the same circuit. If you require an extension cord use
one that is rated at 1875 watts.
SYLVANIA is a registered trademark of OSRAM SYLVANIA, used under license.
2
ASSEMBLY INSTRUCTIONS
parts list:
Fireplace insert .................................................................................................................... 1
A) Top panel ....................................................................................................................... 1
B) Base panel ..................................................................................................................... 1
C) Upper front panel ........................................................................................................ 1
D) Left front panel ............................................................................................................. 1
E) Right front panel........................................................................................................... 1
F) Left side panel .............................................................................................................. 1
G) Right side panel ............................................................................................................ 1
S) Wood connectors ......................................................................................................... 8
T) Short KD screws ........................................................................................................... 5
U) Mounting Clips ............................................................................................................. 3
V) Mounting Brackets ....................................................................................................... 2
W) KD screws .................................................................................................................... 45
X) Plastic Connectors ....................................................................................................... 13
Y) SELF REPAIR SET
Touch-up repair paint (bottle)
L-shape bracket ................................................................................................................... 2
Screws for L bracket ........................................................................................................... 8
Plastic connectors ............................................................................................................... 1
KD screws ............................................................................................................................ 3
KD nuts ................................................................................................................................. 3
Z) WALL ANCHOR SAFETY CABLE
Wall anchor ......................................................................................................................... 1
Screw for wall anchor ........................................................................................................ 1
Screw for mantle ................................................................................................................. 1
Safety cable ...........................................................................................................................1
This fireplace mantel requires 1 - 2 people to assemble and normally takes 45
minutes - 1 hour to complete.
TOOL REQUIRED: PHILLIPS HEAD SCREWDRIVER
MANTEL ASSEMBLY
CAUTION: Place a piece of cardboard or protective sheet on the floor in order to
avoid scratching the decorative surface of your mantle during assembly.
Please DO NOT fully tighten the KD screws until all panels are assembled.
NOTE: Each Plastic Connector is pre-assembled (pre-drilled) on the specific panels
with 2 screws. If the KD screw(s) do not fit during assembly, loosen the 2 (pre-drilled)
screws to adjust the Plastic Connector until the KD screws are able to be installed.
Tighten all KD screws once all panels are assembled.
Step 1: Attach 13 Plastic Connectors [X] to Panel C, D E, F and G with 26 KD screws as
shown in Fig. A. (2 KD screws for each plastic connector). Attach 2 Wood Connectors
[S] to Panel C with 4 KD screws (2 KD screws for each wood connector).
3
Fig. A
Step 2: Attach Left front panel [D] to Left side panel [F] with 2 KD screws. Attach
Right front panel [E] to Right side panel [G] with 2 KD screws. See Fig. B.
Fig. B
Step 3: Attach Left front panel [D] and Left side panel [F] to Base [B] with 3 KD
screws. Attach Right front panel [E] and Right side panel [G] to Base [B] with 3 KD
screws. See Fig. C.
Fig. C
Step 4: Attach Upper front panel [C] to Left and Right front panel [D and E] with 4 KD
screws. See Fig. D.
Fig. D
Step 5: Attach Top panel [A] to the unit as shown in Fig. E with 3 KD screws.
See Fig. E.
Fig. E
Step 6: Tighten all KD SCREWS.