Information for Lot 9 of ErP (Ecodesign)
This addendum addresses European Union (EU) Ecodesign requirements for servers and storage
products. All data and ratings within this addendum are in reference only to the Supermicro product(s) in
th toe manual. The below information conforms requirements laid down in Annex II of the Commission
Regulation 2019/424.
3(1)(a): See Section 1.1 of the system manual for the product type.
3(1)(b): See the title page and preface of the system manual for the trademark and
manufacturer’s address.
3(1)(c): See the title page of the system manual for product model number(s).
3(1)(d): See the serial number the physical system to determine the year of manufacture. on
3(1)(e-j): PSU Efficiency and Power Factor Value able) (From 80 Plus report) (T
PSU Model #: PWS- -804P 1R
Watts: 800W
PSU Efficiency
Power Fact or
% of Rated Load
10 %
20 %
50 %
100 %
50 %
Single Output ( - )AC DC
89.71 %
92.86%
94.40 %
92.74 %
0.99
System (EUT) Efficiency in Power (Table) Idle State
Representative
Configurations
Measured Idle State
Power (W)
Calculated Idle Power
Allowance (W)
High-End Performance
Configuration
215.7
336.63
Typical Configuration
N/A
N/A
Low-End Performance
Configuration
116
230.053
System (EUT) Efficiency in Power (Table) Active State
Representative
Configurations
Active State
Efficiency Score
(Effserver)
Minimum Active State
Efficiency for 2-Socket
Server
High-End Performance
Configuration
30.2
Typical Configuration
N/A
9.5
Low-End Performance
Configuration
23.3
3(1)(k): The operating condition class . is A2
Dry bulb temp C°
Humidity range, non-condensing
Operating
condition
class
Allowable
range
Recom
mended
range
Allowable range
Recommended range
Max dew
point (°C)
Maximum
rate of
change
(°
C/hr)
A1
15 32-
18 27-
–
12 C Dew Point (DP) and°
8 % relative humidity (RH) to
17 80 C DP and ° % RH
–
9 C °DP to
15 C and °DP
60 % RH
17
5/20
A2
10 35-
18 27-
–
12 C and 8 % °DP RH to
21 80 C and °DP % RH
Same as A1
21
5/20
A3
5-40
18 27-
–
12 C and 8 % °DP RH to
24 85 C and °DP % RH
Same as A1
24
5/20
A4
5-45
18 27-
–
12 C and 8 % °DP RH to
24 90 C and °DP % RH
Same as A1
24
5/20
3(1)(l): The idle state power at the higher boundary temperature of the operating conditions
class is 215.7W.
3(1)(m): The active state efficiency and performance 30.2. is
3(1)(n): There are two methods by which a user can securely delete data from this system. The
user performing secure data deletion should be an IT professional.
The first is with a Unified Extensible Firmware Interface (UEFI) shell utility. This utility
works on X10/X11/H11/H12/M11 motherboard series with onboard SATA/NVMe devices.
Any user may access and download this utility through following link:
https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Secure
_Data_Deletion_Utility/
Download the shell utility package and extract it to a USB flash drive, then plug the drive
into the server for which secure data deletion is necessary. Then turn the system on.
Navigate to the BIOS setup menu, then place the server system into the UEFI shell
environment. Follow the instructions in the README file to invoke the utility and
complete the deletion.
The second method is through the secure data deletion tool provided by the original
manufacturer of the hard drive. This should be used in a scenario where the shell utility
is not applicable. Each manufacturer should have the tool available on their website. If
needed, please look on the hard drive label for the name of the manufacturer and model
information.
3(1)(o): List of recommended combinations of blade servers with chassis: N/A.
3(1)(p): List of all current SKUs within this product family: N/A.
3(3)(a): There is no use of cobalt in batteries in this product.
The indicative weight range of neodymium in the HDD is 0.0 if manufactured by Western
Digital, and is between 5-25 grams if manufactured by Seagate.
3(3)(b): Please see the disassembly instructions on the next page.
Specyfikacje produktu
Marka: | Supermicro |
Kategoria: | serwer |
Model: | SuperStorage 6119P-ACR12N4L |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Supermicro SuperStorage 6119P-ACR12N4L, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer Supermicro
11 Stycznia 2025
11 Stycznia 2025
8 Stycznia 2025
28 Grudnia 2024
28 Grudnia 2024
24 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
7 Października 2024
Instrukcje serwer
- serwer Sony
- serwer Lenovo
- serwer Gigabyte
- serwer Acer
- serwer Technics
- serwer Hikvision
- serwer Fujitsu
- serwer Conceptronic
- serwer StarTech.com
- serwer Asus
- serwer TRENDnet
- serwer MSI
- serwer Toshiba
- serwer D-Link
- serwer ATen
- serwer APC
- serwer HP
- serwer Tripp Lite
- serwer Cisco
- serwer Moxa
- serwer Synology
- serwer Lindy
- serwer ZyXEL
- serwer Dell
- serwer Linksys
- serwer Digitus
- serwer Vimar
- serwer Netgear
- serwer Black Box
- serwer ELAC
- serwer Intellinet
- serwer HGST
- serwer Revox
- serwer Naim
- serwer SEH
- serwer Planet
- serwer NEC
- serwer LevelOne
- serwer Digi
- serwer Axis
- serwer Abus
- serwer Rocstor
- serwer Western Digital
- serwer Smart-AVI
- serwer Promise Technology
- serwer QNAP
- serwer Chenbro Micom
- serwer Allnet
- serwer Veritas
- serwer IStarUSA
- serwer Silverstone
- serwer Ernitec
- serwer AVerMedia
- serwer Atlona
- serwer Gefen
- serwer Hanwha
- serwer Quantum
- serwer Blackmagic Design
- serwer Kathrein
- serwer Eaton
- serwer Monacor
- serwer Sonnet
- serwer In Win
- serwer Teo
- serwer Megasat
- serwer Areca
- serwer Kramer
- serwer AMX
- serwer C2G
- serwer Acti
- serwer Sitecom
- serwer Maxdata
- serwer Matrox
- serwer Flir
- serwer Buffalo
- serwer GeoVision
- serwer LaCie
- serwer Valcom
- serwer Asustor
- serwer Intel
- serwer Fantec
- serwer Freecom
- serwer Seagate
- serwer Iomega
- serwer Luxman
- serwer Ibm
- serwer Provision ISR
- serwer TAIDEN
- serwer SIIG
- serwer Advantech
- serwer Extron
- serwer Avocent
- serwer Silex
- serwer Sun
- serwer MvixUSA
- serwer Dual Bay
- serwer Raidsonic
- serwer EMC
- serwer Infortrend
- serwer Opengear
- serwer G-Technology
- serwer EXSYS
- serwer Middle Atlantic
- serwer Mr. Signal
- serwer Atlantis Land
- serwer Lantronix
- serwer NETSCOUT
- serwer Mobotix
- serwer Origin Storage
Najnowsze instrukcje dla serwer
14 Stycznia 2025
14 Stycznia 2025
14 Stycznia 2025
12 Stycznia 2025
11 Stycznia 2025
1 Stycznia 2025
31 Grudnia 2025
31 Grudnia 2025
31 Grudnia 2025
31 Grudnia 2025