SUPERSERVER®
1028TR-T
1028TR-TF
USER’S MANUAL
Revision 1.0

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0
Release Date: March 03, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2015 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America

iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 1028TR-T/TF.
Installation and maintainance should be performed by experienced technicians only.
The SuperServer 1028TR-T/TF is a high-end server based on the SC809TS-1K03BP
1U rackmount chassis and the dual processor X10DRT-L/LIBF serverboard. All
models have an IPMI LAN port and two serverboard nodes with four hot-swap 2.5"
SATA3 Hard Disk Drives (HDD) each per node.
Each of the various models of the SuperServer 1028TR-T/TF servers and their
associated serverboards for each of their unique options are listed in the table below:
SUPERSERVER 1028TR-T/TF Model Variations
Server
Model
X10DRT
Serverboard
Infi niBand
FDR/QDR Connector
1028TR-T X10DRT-L NO
1028TR-TF X10DRT-LIBF YES
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X10DRT-L/LIBF serverboard
and the SC809TS-1K03BP chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 1028TR-T/TF
into a rack and check out the server confi guration prior to powering up the system.
If your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.

SUPERSERVER 1028TR-T/TF User's Manual
iv
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SUPERSERVER 1028TR-T/TF.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X10DRT-L/LIBF serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC809TS-1K03BP server chassis.
You should follow the procedures given in this chapter when installing, removing or
reconfi guring SATA or peripheral drives and when replacing system power supply
units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information
on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specifi cations

v
SUPERSERVER 1028TR-T/TF User's Manual
Notes

vi
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
Serial ATA ....................................................................................................... 1-2
PCI Expansion Slots ....................................................................................... 1-2
Onboard Controllers/Ports .............................................................................. 1-3
Graphics Controller ......................................................................................... 1-3
Infi niBand ........................................................................................................ 1-3
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
SATA Subsystem ............................................................................................. 1-4
Front Control Panel ......................................................................................... 1-4
I/O Ports .......................................................................................................... 1-4
Cooling System ............................................................................................... 1-4
Air Shrouds ..................................................................................................... 1-4
Mounting Rails ................................................................................................ 1-5
1-4 Advanced Power Management ....................................................................... 1-5
Intel® Intelligent Power Node Manager (NM) ................................................. 1-5
Manageability Engine (ME) ............................................................................. 1-5
1-5 Contacting Supermicro .................................................................................... 1-7
1-6 2U Twin2: System Notes ................................................................................. 1-8
Nodes .............................................................................................................. 1-8
System Power ................................................................................................. 1-8
SATA Backplane/Drives ................................................................................... 1-8
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Warnings and Cautions! .................................................................................. 2-2
Choosing a Setup Location ............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
SUPERSERVER 1028TR-T/TF User's Manual

vii
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-5 Rack Mounting Instructions ............................................................................. 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-5
Installing the Inner Rail Extensions ................................................................ 2-6
Installing the Outer Rails ................................................................................. 2-7
Installing the Chassis into a Rack................................................................... 2-8
2-6 Checking the Serverboard Setup .................................................................... 2-9
2-7 Checking the Drive Bay Setup ...................................................................... 2-10
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-2
3-3 Control Panel LEDs ........................................................................................ 3-2
Information LED .............................................................................................. 3-2
Overheating ..................................................................................................... 3-3
3-4 Drive Carrier LEDs .......................................................................................... 3-4
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Defi nition ........................................................................................... 4-1
Installation Instructions .................................................................................... 4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................ 4-10
Redundant Power Supplies .......................................................................... 4-12
Backplane Voltage ........................................................................................ 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Easy Swap Fan Warning .............................................................................. 4-16
Power Cable and AC Adapter ...................................................................... 4-18
Table of Contents

viii
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard .............................................................................. 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Connecting Cables .......................................................................................... 5-2
Connecting Data Cables ................................................................................. 5-2
5-3 Control Panel Connectors and I/O Ports ........................................................ 5-2
Connecting the Control Panel ......................................................................... 5-3
5-4 Processor and Heatsink Installation................................................................ 5-4
Installing a Passive CPU Heatsink ................................................................. 5-8
Removing the Heatsink ................................................................................... 5-9
5-5 Installing Memory .......................................................................................... 5-10
Removing Memory Modules ......................................................................... 5-10
Memory Support .............................................................................................5-11
Maximum Memory ..........................................................................................5-11
Processor & Memory Module Population Confi guration ................................5-11
5-6 Adding PCI Expansion Cards ....................................................................... 5-12
5-7 Motherboard Details ...................................................................................... 5-13
5-8 Connector Defi nitions .................................................................................... 5-16
5-9 Jumper Settings ............................................................................................ 5-23
Explanation of Jumpers ................................................................................ 5-23
5-10 Onboard Indicators ........................................................................................ 5-25
5-11 PCI-Express and Serial ATA Connections .................................................... 5-27
5-12 Installing Drivers ............................................................................................ 5-28
SuperDoctor 5 ............................................................................................... 5-29
5-13 Serverboard Battery ...................................................................................... 5-31
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
Unpacking ....................................................................................................... 6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 Removing Power from the System ................................................................. 6-2
6-4 Chassis Cover ................................................................................................. 6-3
6-5 Installing the Air Shrouds ................................................................................ 6-4
Air Shrouds ..................................................................................................... 6-4
6-6 System Fans ................................................................................................... 6-5
6-7 Installing Hard Drives ...................................................................................... 6-6
SUPERSERVER 1028TR-T/TF User's Manual

6-8 Motherboard Installation .................................................................................. 6-9
I/O Shield ........................................................................................................ 6-9
Permanent and Optional Standoffs ................................................................. 6-9
Installing the Motherboards ............................................................................. 6-9
6-9 Expansion Slot Setup .....................................................................................6-11
5-9 Power Supply ............................................................................................... 6-12
Power Supply Replacement .......................................................................... 6-12
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data ......................................................... 7-1
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Settings Menu ................................................................................ 7-4
4-4 Event Logs .................................................................................................... 7-30
4-5 IPMI ............................................................................................................... 7-32
4-6 Security Settings ........................................................................................... 7-34
4-7 Boot Settings ................................................................................................. 7-37
4-8 Save & Exit ................................................................................................... 7-39
Appendix A BIOS Error Beep Codes
Appendix B System Specifi cations
ix
Table of Contents

x
Notes
SUPERSERVER 1028TR-T/TF User's Manual

Chapter 1
Introduction
1-1 Overview
The SuperServer 1028TR-T/TF is a high-end server comprised of two main
subsystems: the SC809TS-1K03BP 1U server chassis and the X10DRT-L/LIBF
dual processor serverboard in two hot-swap nodes. Please refer to our web site for
information on operating systems that have been certifi ed for use with the system
(www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the SuperServer 1028TR-T/TF server, as listed below:
• Heat Sinks
Two (2) 1U passive CPU heat sinks for rear CPU (SNK-P0047PW)
Two (2) 1U passive CPU heat sinks w/narrow ILM (SNK-P0047PS)
• Two (2) Mylar air shrouds (MCP-310-80803-0B)
• Six (6) 40x56-mm 4-pin PWM cooling fans (FAN-0101L4)
• Two (2) 20" 28AWG 20-to-20-pin ribbon front control cables (CBL-0086)
• SATA Backplane
Two (2) Backplanes for four (4) 2.5" SATA HDD (BPN-SAS-809TQ)
Eight (8) hot-swap 2.5" HDD trays (MCP-220-00047-0B)
Two (2) 45-cm 30AWG S-RA SATA cables (CBL-SAST-0641)
Two (2) 61.5-cm 28AWG 8-pin to 8-pin SGPIO cables (CBL-CDAT-0662)
Four (4) 55-cm 30AWG SATA cables (CBL-0488L)
Two (2) 55-cm 30AWG SATA cables (CBL-0484L)
• Two (2) Riser cards (RSC-R1UTP-E16R-O-P)
• One (1) Rail set (MCP-290-00042-0V)
Note: For your system to work properly, please follow the links below to download
all necessary drivers/utilities and the user’s manual for your server.
• Supermicro product manuals: http://www.supermicro.com/support/manuals/
• Product drivers and utilities: ftp://ftp.supermicro.com
• Product safety information:
http://super-dev/about/policies/safety_information.cfm
• If you have any questions, please contact our support team at:
support@supermicro.com
Chapter 1: Introduction
1-1

1-2
SUPERSERVER 1028TR-T/TF User's Manual
1-2 Serverboard Features
A t t h e h e a r t o f t h e S u p e r S e r v e r 1 0 2 8 T R - T / T F l i e s t h e
X10DRT-L/LIBF, a dual processor serverboard based on the Intel®
C612 chipset and designed to provide maximum performance. Two of these
serverboards can be mounted in the SC809TS-1K03BP chassis.
The sections below cover the main features of the X10DRT-L/LIBF serverboard
(see Figure 1-1 for a block diagram of the chipset).
Processors
The X10DRT-L/LIBF supports single or dual Intel® Xeon® E5-2600 v3 Series
processors (Socket R3-LGA 2011). Please refer to the serverboard description
pages on our web site for a complete listing of supported processors (www.
supermicro.com).
Memory
The X10DRT-L/LIBF has eight (8) DIMM slots supporting up to 256 GB of RDIMM
registered ECC or 512 GB of LRDIMM DDR4 (288-pin) ECC 2133/1866/1600 MHz
speed SDRAM in 512 MB, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB, 32 GB or 64 GB sizes
at 1.2V voltages. See Chapter 5 for details.
Note: Check the Supermicro website (www.supermicro.com) for the latest memory
support information.
Serial ATA
A Serial ATA controller is integrated into the C612 to provide up to twelve SATA3
ports, (six SATA 3 (6 Gb/s) (I-SATA 0-5) and four S-SATA 3 (6 Gb/s) (S-SATA 0-3),
RAID 0, 1, 5 and 10 supported. The SATA drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the SATA drives.
Note: S-SATA2/S-SATA3: can be used as Supermicro SuperDOM (Disk-on-Module)
with built-in power connectors.
PCI Expansion Slots
The SuperServer 1028TR-T/TF has for each node One (1) PCI-Express 3.0 x16 slot
available for use with a riser card.

1-3
Chapter 1: Introduction
Onboard Controllers/Ports
One Fast UART 16550 port, a single Infi niBand connector with FDR/QDR support
1028TR-TF only), a VGA (monitor) port, an IPMI dedicated LAN port and two
Ethernet ports, and two USB 2.0 ports (additional one internal USB Type-A
connector is included on the serverboard) are all available on the IO back panel.
Note: For IPMI Confi guration Instructions, please refer to the Embedded BMC
Configuration User's Guide available @ http://www.supermicro.com/support/
manuals/.
Graphics Controller
The X10DRT-L/LIBF features an integrated ASpeed 2400 BMC Video Controller.
Infi niBand
The server include an FDR (fourteen data rate) speed Infi niBand QSFP connector.
InfiniBand is a scalable serial communications link intended for connecting
processors with high-speed peripherals.
Other Features
Other onboard features that promote system health include onboard voltage
monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and
CPU overheat sensors, virus protection, node manager software and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC809 server chassis.
System Power
Each SC809 chassis model includes a high-effi ciency Titanium level certifi ed
power supply, rated at 1000 Watts. In the unlikely event your power supply fails,
replacement is simple and can be accomplished without tools.
Note: The power supply is hot-plug.

1-4
SUPERSERVER 1028TR-T/TF User's Manual
SATA Subsystem
The SC809 supports two nodes with up to four (4) 2.5" hot-swap SATA drives in
trays for each node for a total of eight drives. These drives are hot-swappable units
and are connected to a backplane that provides power and control. Hard drives
must be purchased separately. For the latest shipping lists, visit our Web site at:
http://www.supermicro.com.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the drives.
Front Control Panel
SC809TS-1K03BP chassis includes two front panels on the chassis (one each node)
which control each of the systems. Each control panel on the SUPERSERVER
1028TR-T/TF provides you with system monitoring and control for one server
node. LEDs indicate system power, HDD activity, network activity, system overheat
and power supply failure. A main power button and a system reset button are also
included.
I/O Ports
The SC809 is an proprietary form factor chassis designed to be used in a 1U
rackmount confi guration. The SC809 chassis provides a low-profi le add-on card
slot, a COM port, a VGA port, two USB 2.0 ports, an Infi niBand port (1028TR-TF
only), one IPMI Ethernet port and two gigabit Ethernet ports per node.
Cooling System
The SC809 chassis accepts six (6) 4-cm system fans powered from either backpane
or the serverboards. If not powered from the backpane, the SC809TS-1K03BP
model chassis powers three fans from each of the two motherboards, so that when
one of the motherboard drawers is removed, the other motherboards will continue
running its fans.
Note: The fans in this system are NOT redundant, hot-plug.
Air Shrouds
The SC809 chassis includes two mylar air shrouds that funnel air directly to where
it is needed. Always use the air shroud included with your chassis.

1-5
Chapter 1: Introduction
Mounting Rails
The SC809 includes a set of rails, and can be placed in a rack for secure storage and
use. To setup your rack, follow the step-by-step instructions included in this manual.
1-4 Advanced Power Management
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with
real-time thermal control and power management for maximum energy effi ciency.
Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard
Management Controller), your system must also have IPNM-compatible
Manageability Engine (ME) fi rmware installed to use this feature.
Manageability Engine (ME)
The Manageability Engine, which is an ARC controller embedded in the IOH (I/O
Hub), provides Server Platform Services (SPS) to your system. The services
provided by SPS are different from those proveded by the ME on client platforms.

1-6
SUPERSERVER 1028TR-T/TF User's Manual
Figure 1-1. AMD C612 Chipset:
System Block Diagram
SPI
LAN3
RGMII
Debug Card
FRONT PANEL
CTRL
FAN SPEED
PCI-E X1 G2
USB 2.0
Rev. 1.00
#12 USB2.0
X10DRT-L/LIBQ/LIBF
#1/#2/#4/#5/6/7/8
PCH
6.0 Gb/S
USB 2.0
LPC
USB
#1
#0
RTL8211E-VB-CG
RJ45
BIOS
SPI
SPI
Temp Sensor
W83773G
TPM HEADER
USB 3.0
USB
BIOS
HEADER
SPI
AST2400
BMC
RMII/NCSI
COM1
ConnectorVGA CONN
BMC Boot Flash
DDR3
5 PHASE
145W
P2
P2
P1
VR12.5
P1
#1-3
#1-2
SLOT 1
PCI-E X16 G3
DMI2
PCI-E X16
PCI-E X8 G3
SNB CORE
DDR4
SNB CORE
DDR4
QPI
9.6G
4GB/s
5 PHASE
145W
VR12.5
#3B #1
#2
#2-4
<=1.758W (average)
2.3W (Peak)
TDP: 5W (SERVER)
Idle:0.45W
5V:1.2A
3.3V:0.1A
3.3 STBY:0.2A
1.05 PCH
1.05 ASW
1.5 PCH
PVCCIO 1.0/0.95
3.3STBY:0.5A
PCI-E X4 G3
i350
LAN1
#3
#3A
x2 rear port
Mellanox CX3
IB QDR/FDR
S-SATA
I-SATA
6.0 Gb/S
SPI Switch
SPI
#2
#3
#1
#0
#2
#3
#4
#5
#2 and #3 for SATA DOM SUPPORTED
USB 2.0
USB 3.0
TYPE A
#2-3
#2-2
#2-1
1866/2133
DDR4
#1-4
#1-1
1866/2133
DDR4
SATASATA
#2 #3B
#3A #1
CPU1 CPU2
DMI2 DMI2
Note 1: This is a general block diagram and may not exactly represent the
features on your motherboard. See the Motherboard Features pages for the actual
specifi cations of each motherboard.
Note 2: Both CPUs need to be installed for full access to the PCI-E slots, DIMM
slots, and onboard controllers. Refer to the block diagram above to determine which
slots or devices may be affected.

1-7
Chapter 1: Introduction
1-5 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website: www.supermicro.nl
Asia-Pacifi c
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Website: www.supermicro.com.tw

1-8
SUPERSERVER 1028TR-T/TF User's Manual
1-6 2U Twin2: System Notes
As a 1U Twin2 confi guration, the SuperServer 1028TR-T/TF is a unique server
system. With two system boards incorporated into a single chassis acting as two
separate nodes, there are several points you should keep in mind.
Nodes
Each of the two serverboards act as a separate node in the system. As independant
nodes, each may be powered off and on without affecting the others. In addition,
each node is a hot-swappable unit that may be removed from the rear of the chassis.
The nodes are connected to the server backplane by means of an adapter card.
Note: A guide pin is located between the upper and lower nodes on the inner chassis
wall. This guide pin also acts as a “stop” when a node is fully installed. If too much
force is used when inserting a node this pin may break off. Take care to slowly slide
a node in until you hear the “click” of the locking tab seating itself.
System Power
Dual 1000 Watt power supplies are used to provide the power for all serverboards.
Each serverboard however, can be shut down independently of the other with the
power button on its own control panel.
SATA Backplane/Drives
As a system, the SuperServer 1028TR-T/TF supports the use of eight 2.5" SATA
drives. A single SATA backplane works to apply system-based control for power and
fan speed functions, yet at the same time logically connects a set of four SATA drives
to each serverboard. Consequently, RAID setup is limited to a four-drive scheme
(RAID cannot be spread across all drives). See the Drive Bay Installation/Removal
section in Chapter 6 for the logical hard drive and node confi guration.

Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 1028TR-T/TF
up and running. Following these steps in the order given should enable you to have
the system operational within a minimum amount of time. This quick setup assumes
that your system has come to you with the processors and memory preinstalled. If
your system is not already fully integrated with a serverboard, processors, system
memory etc., please turn to the chapter or section noted in each step for details on
installing speci c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 1028TR-T/TF was shipped in and note
if it was damaged in any way. If the server itself shows damage you should le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer
1028TR-T/TF. It should be situated in a clean, dust-free area that is well ventilated.
Avoid areas where heat, electrical noise and electromagnetic elds are generated.
You will also need it placed near a grounded power outlet. Read the Rack and
Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 1028TR-T/TF was shipped in should include two sets of
rail assemblies, two rail mounting brackets and the mounting screws you will need
to install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimum amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.

2-2
SUPERSERVER 1028TR-T/TF User's Manual
2-4 Warnings and Cautions!
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suf cient air ow and ease in servicing.
• This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow any hot plug drives and power supply modules to cool before touching
them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.

Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating
temperature of the rack environment may be greater than the ambient temperature
of the room. Therefore, consideration should be given to installing the equipment
in an environment compatible with the manufacturer’s maximum rated ambient
temperature (Tmra).
Reduced Air ow
Equipment should be mounted into a rack so that the amount of air ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack
itself should be grounded. Particular attention should be given to power supply
connections other than the direct connections to the branch circuit (i.e. the use of
power strips, etc.).

2-4
SUPERSERVER 1028TR-T/TF User's Manual
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
2-5 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean that
the assembly procedure will differ slightly. You should also refer to the installation
instructions that came with the rack unit you are using.
NOTE: This rail will t a rack between 26" and 33.5" deep.
Warning: Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Stability Hazard: The rack stabilizing mechanism must be in place, or the
rack must be bolted to the oor before you slide the unit out for servicing. Failure to
stabilize the rack can cause the rack to tip over.
Warning: Slide rail mounted equipment is not to be used as a shelf or a work
space.

Chapter 2: Server Installation
2-5
Identifying the Sections of the Rack Rails
The chassis package includes two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner xed chassis rail that secures directly to
the server chassis and an outer xed rack rail that secures directly to the rack itself.
Figure 2-1: Identifying the Sections of the Rack Rails
(Right side rail shown)
Rail Extension
(Inner Rail is preinstalled
to the chassis)
Outer Rails

2-6
SUPERSERVER 1028TR-T/TF User's Manual
Installing the Inner Rail Extensions
The chassis includes a set of inner rack rails in two sections: inner rails (A) and
inner rail extensions (B). The inner rails are preattached and do not interfere with
normal use of the chassis if you decide not to use a server rack. Attach the inner
rail extensions to to the inner rails, to stabilize the chassis within the rack.
Installing the Inner Rail Extensions
1. Place the inner rail extensions (B) over the preattached inner rails (A) which
are attached to the side of the chassis. Align the hooks of the inner rail with
the rail extension holes. Make sure the extension faces outward just like the
inner rail.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis with screws as illustrated.
4. Repeat steps 1-3 for the other inner rail extension.
Figure 2-2. Installing the Inner Rail Extensions
1
2
1
1
Inner Rail
Extension
Inner Rail
Preattached to the
Chassis
1
A1
B
1
3

Chapter 2: Server Installation
2-7
Installing the Outer Rails
Installing the Outer Rails to the Rack
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the other outer rail.
Figure 2-3. Assembling the Outer Rails
Outer Rail
Secure to the
Front of the Rack
Secure to the
Rear of the Rack
Secure Outer Rails
Together

Chapter 2: Server Installation
2-9
2-6 Checking the Serverboard Setup
After you install the SuperServer 1028TR-T/TF in the rack, you will need to open
the unit to make sure the serverboard is properly installed and all the connections
have been made.
Accessing the inside of the System
Before operating the server for the rst time, it is important to remove the protective
lm covering the top of the chassis, in order to allow for proper ventilation and
cooling.
Removing the Chassis Cover
1. Disconnect the chassis from any power source and remove all four screws.
2. Gently push down on the chassis cover in the areas indicated in the
illustration.
3. Push the cover toward the rear of the chassis and lift the cover upwards and
off the chassis.
4. Peel off the protective lm covering the top cover and the top of the chassis
5. Check that all ventilation openings on the top cover and the top of the chassis
are clear and unobstructed.
Figure 2-5. Accessing the Inside of the System
1
3
1
4
Caution: Except for short periods of time, do NOT operate the server without
the cover in place. The chassis cover must be in place to allow proper air ow
and prevent overheating.

Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel and on the drive carriers to keep you
constantly informed of the overall status of the system. SC809 models include
four front panels on the handles of the chassis which control each of the systems.
This chapter explains the meanings of all LED indicators and the appropriate
response you may need to take.
Figure 3-1. Control Panel

Chapter 3: System Interface
3-3
Power: Indicates power is being supplied to the system power supply units. This
LED should normally be illuminated when the system is operating.
HDD: Indicates activity on the hard drives when ashing.
NIC1: Indicates network activity on GLAN1 when ashing.
Overheating
There are several possible responses if the system overheats.
Overheat Temperature Setting
Some backplanes allow the overheat temperature to be set at 45°, 50°, or 55° C by
changing a jumper setting. For more information, consult the backplane user manual
at www.supermicro.com. (Click Support, then the Manuals link.)
Responses
If the server overheats:
1. Use the LEDs to determine the nature of the overheating condition.
2. Con rm that the chassis covers are installed properly.
3. Check the routing of the cables and make sure all fans are present and
operating normally.
4. Verify that the heatsinks are installed properly.

SUPERSERVER 1028TR-T/TF User's Manual
3-4
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA drives. Each drive carrier
displays two status LEDs on the front of the carrier.
LED Color State Status
Activity LED Green Solid On SAS drive installed
Green Blinking I/O activity
Status LED Red Solid On Failed drive for SAS/SATA with RSTe
support
Red Blinking at 1 Hz Rebuild drive for SAS/SATA with RSTe
support
Red Blinking with two blinks
and one stop at 1 Hz
Hot spare for SAS/SATA with RSTe
support
Red On for ve seconds,
then off
Power on for SAS/SATA with RSTe
support
Red Blinking at 4 Hz Identify drive for SAS/SATA with RSTe
support

4-1
Chapter 4: Warning Statements for AC Systems
Chapter 4
Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certi ed technicians should attempt to install or con gure
components.
Read this appendix in its entirety before installing or con guring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning De nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
警告の定義
この警告サインは危険を意味します。
人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、
電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。
此警告符号代表危险。
您正处于可能受到严重伤害的工作环境中。在您使用设备开始工作之前,必须充分
意识到触电的危险,并熟练掌握防止事故发生的标准工作程序。请根据每项警告结
尾的声明号码找到此设备的安全性警告说明的翻译文本。
此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸
電的危險,並且要熟悉預防事故發生的標準工作程序。請依照每一注意事項後的號
碼找到相關的翻譯說明內容。

4-2
SUPERSERVER 1028TR-T/TF User's Manual
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie be nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la n de chaque avertissement.
CONSERVEZ CES INFORMATIONS.
ןונקת
ןונקת
ןונקת
ןונקתןונקת
תורהצה
תורהצה
תורהצה
תורהצהתורהצה
א
א
א
אא
הרהז
הרהז
הרהז
הרהזהרהז
ןה תואבה תורהצהא , ינפמ שמתשמה תא ריהזהל תנמ לע היישעתה ינקת יפ לע תורהז הלבח
ה וא תולאש שיו הדימב .תירשפא תיזיפי , יהשלכ היעבב תולקתרוציל שי הכימת תקלחמ םע רשק
רידגהל וא ןיקתהל םיאשר דבלב םיכמסומ םיאנכט .ורקימרפוס לש תינכ תאה .םיביכר
אורקל שי . ורקימרפוס יזראמב םיביכרה תרדגה וא תנקתה ינפל ואולמב חפסנה תא

4-3
Warning Statements for AC Systems
!
.
.
.
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken,
dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's
en dient u op de hoogte te zijn van de standaard procedures om ongelukken te
voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te
herleiden naar de desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES
. ﻲﻓ ﻚﻧﺍ ﻥﺃ ﻦﻜﻤﻳ ﺔﻟﺎﺣ ﻲﻓ ﺐﺒﺴﺘﺗ ﺔﺑﺎﺻﺍ ﺔﻳﺪﺴﺟ ﺰﻣﺮﻟﺍ ﺍﺬﻫ ﻲﻨﻌﻳ ﺮﻄﺧ !ﺮﻳﺬﺤ
ﻥﺃ ﻞﺒﻗ ﻱﺃ ﻰﻠﻋ ﻞﻤﻌﺗ ﺕﺍﺪﻌﻣ،ﻛﻢﻠﻋ ﻰﻠﻋ ﻦ ﻦﻋ ﺔﻤﺟﺎﻨﻟﺍ ﺮﻁﺎﺨﻤﻟﺎﺑ ﺮﺋﺍﻭﺪﻟﺍ ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ
ﻛﻭﺔﻳﺍﺭﺩ ﻰﻠﻋ ﻦ ﺭﺎﻤﻤﻟﺎﺑﺕﺎﺳ ﺔﻴﺋﺎﻗﻮﻟﺍ ﻟ ﻊﻨﻤﻉﻮﻗﻭ ﻱﺃﺙﺩﺍﻮﺣ
ﻢﻗﺭ ﻡﺪﺨﺘﺳﺍ ﻥﺎﻴﺒﻟﺍ ﺹﻮﺼﻨﻤﻟﺍ ﺔﻳﺎﻬﻧ ﻲﻓ ﺮﻳﺬﺤﺗ ﻞﻛ ﺭﻮﺜﻌﻠﻟ ﺎﻬﺘﻤﺟﺮﺗ

4-4
SUPERSERVER 1028TR-T/TF User's Manual
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power source.
設置手順書
システムを電源に接続する前に、設置手順書をお読み下さい。
警告
将此系统连接电源前,请先阅读安装说明。
警告
將系統與電源連接前,請先閱讀安裝說明。
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.
¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.
Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives
d'installation.
ﻟﺍ ﺕﺍﺩﺎﺷﺭﺇ ﺮﻗﺍﺐﻴﻛﺮﺘ ﻞﻴﺻﻮﺗ ﻞﺒﻗ ﻰﻟﺇ ﻡﺎﻈﻨﻟﺍ ﺔﻗﺎﻄﻠﻟ ﺭﺪﺼﻣ
אורקל שי רוקמל תכרעמה רוביח ינפל הנקתה תוארוה תאחתמ.
.
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.

4-6
SUPERSERVER 1028TR-T/TF User's Manual
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power cord
removed from the power supply module(s) before accessing the chassis interior to
install or remove system components.
電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス
するには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。
警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
!
()
. 250V(), 20A()
.
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische
installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan
220V, 20A.
ﺞﺘﻨﻤﻟﺍ ﺍﺬﻫ ﻰﻠﻋ ﺪﻤﺘﻌﻳ ﺕﺍﺪﻌﻣ ﺔﻳﺎﻤﺤﻟﺍ ﺓﺮﻴﺼﻘﻟﺍﺮﺋﺍﻭﺪﻟﺍ ﻦﻣ ﺎﻬﺘﻴﺒﺜﺗ ﻢﺗ ﻲﺘﻟﺍ ﻲﻓ ﻰﻨﺒﻤﻟﺍ
20A, 250V : ﻦﻣ ﺪﻛﺄﺗ ﻥﺃ ﻢﻴﻴﻘﺗ ﺯﺎﻬﺠﻟﺍ ﻟﺍﻲﺋﺎﻗﻮ ﺲﻴﻟ ﻦﻣ ﺮﺜﻛﺃ

4-7
Chapter 4: Warning Statements for AC Systems
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es
auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder
zu entfernen.
¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable
eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso
el interior del chasis para instalar o para quitar componentes de sistema.
Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de
son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour
installer ou enlever des composants de systéme.
ילמשח
ילמשח
ילמשח
ילמשחילמשח קותינ
קותינ
קותינ
קותינקותינ ינפמ
ינפמ
ינפמ
ינפמינפמ הר
הר
הר
הרהר
!
!
!
!!הרהזא
הרהזא
הרהזא
הרהזאהרהזא
למשחה תורוקמ לכמ תכרעמה תא קתנל ש ריסהל שיו קפסהמ ילמשחה לבכ תא
נקתה ךרוצל זראמה לש ימינפה קלחל השיג ינפת רסה ואת .םיביכר
ﻞﺼﻓ ﺐﺠﻳ ﻡﺎﻈﻨﻟﺍ ﻊﻴﻤﺟ ﻦﻣﺭﺩﺎﺼﻣ ﺔﻗﺎﻄﻟﺍ ﺔﻟﺍﺯﺇﻭ ءﺎﺑﺮﻬﻜﻟﺍ ﻚﻠﺳ ﻦﻣ ﺓﺪﺣﻭ ﺩﺍﺪﻣﺍ ﺔﻗﺎﻄﻟﺍ ﻞﺒﻗ
ﻰﻟﺇ ﻝﻮﺻﻮﻟﺍ ﺔﻴﻠﺧﺍﺪﻟﺍ ﻖﻁﺎﻨﻤﻟﺍ ﻟﻞﻜﻴﻬﻠ ﺔﻟﺍﺯﺇ ﻭﺃ ﺖﻴﺒﺜﺘﻟ ﺕﺎﻧﻮﻜﻣ ﺯﺎﻬﺠﻟﺍ
!
.
Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren
of verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle
stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen

4-10
SUPERSERVER 1028TR-T/TF User's Manual
Battery Handling
Warning!
There is the danger of explosion if the battery is replaced incorrectly. Replace the
battery only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions
電池の取り扱い
電池交換が正しく行われなかった場合、破裂の危険性があります。交換する電池はメー
カーが推奨する型、または同等のものを使用下さい。使用済電池は製造元の指示に従
って処分して下さい。
警告
电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更
换原有电池。请按制造商的说明处理废旧电池。
警告
電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有
電池。請按照製造商的說明指示處理廢棄舊電池。
תלבגומ
תלבגומ
תלבגומ
תלבגומתלבגומ השיג
השיג
השיג
השיגהשיג םע
םע
םע
םעםע רו
רו
רו
רורו
!
!
!
!!הרהזא
הרהזא
הרהזא
הרהזאהרהזא
. תרזעב תנתינ השיגה השיג תלבגה םהב שיש םירוזאב הדיחיה תא ןיקתה
.('דכו לוענמ ,חתפמ) דבלב החטבא ילכ
. ﺺﻴﺼﺨﺗ ﺓﺪﺣﻮﻟﺍ ﻩﺬﻫ ﻲﻓ ﺎﻬﺒﻴﻛﺮﺘﻟ ﻖﻁﺎﻨﻣ ﺓﺭﻮﻈﺤﻣ ﻢﺗ
ﺻﻮﻟﺍ ﻦﻜﻤﻳﻰﻟﺇ ﻝﻮ ﺔﻘﻄﻨﻣ ﺓﺭﻮﻈﺤﻣ ﻂﻘﻓ ﻡﺍﺪﺨﺘﺳﺍ ﻝﻼﺧ ﻦﻣ ،ﺔﺻﺎﺧ ﺓﺍﺩﺃ
ﻭﺃ ﻱﺃ ﻼﻟ ﻯﺮﺧﺃ ﺔﻠﻴﺳﻭﻥﺎﻣﻷ ﺡﺎﺘﻔﻣﻭ ﻞﻔﻗ
!
. ,
, .
Waarschuwing
Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang.
Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te
maken van speciaal gereedschap, slot en sleutel of andere veiligheidsmaatregelen.

4-14
SUPERSERVER 1028TR-T/TF User's Manual
Comply with Local and National Electrical Codes
Warning!
Installation of the equipment must comply with local and national electrical codes.
地方および国の電気規格に準拠
機器の取り付けはその地方および国の電気規格に準拠する必要があります。
警告
设备安装必须符合本地与本国电气法规。
警告
設備安裝必須符合本地與本國電氣法規。
Warnung
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.
ﻙﺎﻨﻫ ﺮﻄﺧ ﻦﻣ ﻲﺋﺎﺑﺮﻬﻜﻟﺍ ﺭﺎﻴﺘﻟﺍ ﻰﻠﻋ ﺓﺩﻮﺟﻮﻤﻟﺍ ﺔﻗﺎﻄﻟﺍﻭﺃ ﺔﺣﻮﻠﻟﺍ
ﻥﻮﻜﻳ ﺎﻣﺪﻨﻋﻡﺎﻈﻨﻟﺍ ﻞﻤﻌﻳ ﺪﻨﻋ ﺍﺭﺬﺣ ﻦﻛ ﺔﻣﺪﺧ ﺯﺎﻬﺠﻟﺍ ﺍﺬﻫ
경고!
시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생
합니다. 서비스 작업 시 주의하십시오.
Waarschuwing
Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het
systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.
ירוחאה
ירוחאה
ירוחאה
ירוחאהירוחאה לנפב
לנפב
לנפב
לנפבלנפב חתמ
חתמ
חתמ
חתמחתמ
זא!הרה
ךלהמב רהזיהל שי .תכרעמה לועפת ןמזב לנפב ירוחאה חתמ תנכס תמייק
.הדובעה
Attention
Lorsque le système est en fonctionnement, des tensions électriques circulent sur
le fond de panier. Prendre des précautions lors de la maintenance.

4-16
SUPERSERVER 1028TR-T/TF User's Manual
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen
des Landes erfolgen.
¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y
reglamentos nacionales.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des
lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de
l'organisme compétent.
Easy Swap Fan Warning
Warning!
The fans might still be turning when you remove the fan assembly from the chassis.
Keep fi ngers, screwdrivers, and other objects away from the openings in the fan
assembly's housing.
ファン・ホットスワップの警告
シャーシから冷却ファン装置を取り外した際、ファンがまだ回転している可能性があり
ます。ファンの開口部に、指、ドライバー、およびその他のものを近づけないで下さい。
警告
רצומה
רצומה
רצומה
רצומהרצומה קוליס
קוליס
קוליס
קוליסקוליס
!הרהזא
ו תויחנהל םאתהב תויהל בייח הז רצומ לש יפוס קוליס. הנידמה יקוח
ﻲﺋﺎﻬﻨﻟﺍ ﺺﻠﺨﺘﻟﺍ ﻦﻣ ﺞﺘﻨﻤﻟﺍ ﺍﺬﻫ ﻪﻌﻣ ﻞﻣﺎﻌﺘﻟﺍ ﻲﻐﺒﻨﻳ ﻟ ﺎﻘﻓﻭ ﻊﻴﻤﺠﺔﻴﻨﻁﻮﻟﺍ ﺢﺋﺍﻮﻠﻟﺍﻭ ﻦﻴﻧﺍﻮﻘﻟﺍ ﺪﻨﻋ
경고!
이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.

4-17
Chapter 4: Warning Statements for AC Systems
!הרהזא
יקלח תא רשאכ םיריסמ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה
קיחרהללררוואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה חוטב תא קחרמ
ﻦﻜﻤﻤﻻﺍ ﻦﻣ ﺡﻭﺍﺮﻤﻻﺍ ﻥﺃ ﻝﺍﺰﺗ ﻻ ﺔﻻﺍﺯﺇ ﺪﻨﻋﺭﻭﺪﺗ ﺔﻠﺘﻛ ﺔﺣﻭﺮﻤﻻﺍ ﻞﻜﻴﻬﻻﺍ ﻦﻣ ﺐﺠﻳ ءﺎﻘﺑﺇ
ﻊﺑﺎﺻﻷﺍ ﻭﻲﻏﺍﺮﺒﻻﺍ ﺕﺎﻜﻔﻣ
.ءﺎﻴﺷﻷﺍ ﻦﻣ ﺎﻫﺮﻴﻏﻭ ﺍﺪﻴﻌﺑ ﻦﻋ ﺕﺎﺤﺘﻔﻻﺍ ﻲﻓ ﺔﻠﺘﻛ ﺔﺣﻭﺮﻤﻻﺍ
경고!
섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬
조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이
가까이 하지 않도록 배치해 주십시오.
当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他
物品太靠近风扇
警告
當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他
物品太靠近風扇。
Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis
genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände
von den Öffnungen des Lüftergehäuses entfernt.
¡Advertencia!
Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador
del chasis. Mandtenga los dedos, los destornilladores y todos los objetos lejos de
las aberturas del ventilador
Attention
Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez
le bloc ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres
objets soient éloignés du logement du bloc ventilateur.

4-20
SUPERSERVER 1028TR-T/TF User's Manual
Waarschuwing
Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels,
stroomkabels en adapters. Het gebruik van andere kabels en adapters kan leiden
tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet
verbiedt het gebruik van UL of CSA gecertifi ceerde kabels die UL of CSA die op
de code voor andere elektrische apparaten dan de producten die door Supermicro
alleen.
Specyfikacje produktu
Marka: | Supermicro |
Kategoria: | serwer |
Model: | SuperServer 1028TR-T |
Kolor produktu: | Czarny, Srebrny |
Wbudowany wyłącznik: | Tak |
Częstotliwość wejściowa AC: | 50 - 60 Hz |
Napięcie wejściowe AC: | 100 - 240 V |
Wysokość produktu: | 43 mm |
Szerokość produktu: | 437 mm |
Głębokość produktu: | 705 mm |
Prędkość transferu danych przez Ethernet LAN: | 10,100,1000,10000 Mbit/s |
Ilość portów Ethernet LAN (RJ-45): | 2 |
Zakres temperatur (eksploatacja): | 10 - 35 °C |
Zakres wilgotności względnej: | 8 - 90 % |
Typ procesora: | Intel |
Liczba portów USB 2.0: | 2 |
Przewodowa sieć LAN: | Tak |
Zakres temperatur (przechowywanie): | -40 - 70 °C |
Dopuszczalna wilgotność względna: | 5 - 95 % |
Ilość obsługiwanych rozmiarów dysków pamięci: | 4 |
Obsługiwane rozmiary dysków pamięci: | 2.5 " |
Obudowa: | Rack (1U) |
Liczba wentylatorów: | 3 went. |
Obsługiwane rodzaje pamięci: | DDR4-SDRAM |
Maksymalna pojemność pamięci: | 512 GB |
Gniazdo procesora: | LGA 2011 (Socket R) |
Procesor: | Intel® Xeon® |
Układ płyty głównej: | Intel® C612 |
Poziomy raid: | 0, 1,5, 10 |
Typ BIOS: | EEPROM |
PCI Express x16 gniazda: | 1 |
Ilość złączy SATA III: | 10 |
Zasilanie: | 1000 W |
Wspierane interfejsy dysków twardych: | Serial ATA III |
Rodzaj interfejsu sieci Ethernet: | 10 Gigabit Ethernet, Fast Ethernet, Gigabit Ethernet |
Kontroler LAN: | Intel® I350 |
Liczba portów VGA (D-Sub): | 1 |
Korekcja ECC: | Tak |
Rozmiar pamięci BIOS: | 128 Mbit |
Wersja ACPI: | 4.0 |
Technologia okablowania Copper Ethernet: | 1000BASE-T, 100BASE-TX, 10BASE-T, 10GBASE-T |
Wskaźnik magistrali systemowej: | 9.6 GT/s |
Model karty graficznej on-board: | Aspeed AST2400 |
Szeregowe porty komunikacyjne: | 1 |
Wersja gniazd typu Slot (PCI Express): | 3.0 |
Rodzaj pamięci: | 288-pin DIMM |
Napięcie pamięci: | 1.2 V |
Intel® Xeon series: | E5-2600 |
Ilość slotów DIMM: | 8 |
Liczba obsługiwanych procesorów: | 2 |
Prędkość zegara pamięci RDIMM: | 1600,1866,2133 MHz |
Przemieszczanie twardej wnęki na napęd HDD: | Tak |
Magistrala pamięci: | 72 bit |
Maksymalna pojemność pamięci RDIMM: | 256 GB |
Maksymalna pojemność pamięci UDIMM: | 512 GB |
Obsługuje rozmiary DIMM: | 16GB, 32GB, 4GB, 8GB |
Prąd stały (+5 V): | 4 A |
Prąd stały (+12 V): | 75 A |
Port IPMI LAN (RJ-45): | Tak |
Maksymalna pamięć podręczna: | 45 MB |
Typ magistrali systemowej: | QuickPath Interconnect (QPI) |
Funkcje BIOS: | Plug & Play, UEFI |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Supermicro SuperServer 1028TR-T, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer Supermicro

30 Stycznia 2025

11 Stycznia 2025

11 Stycznia 2025

8 Stycznia 2025

28 Grudnia 2024

28 Grudnia 2024

24 Października 2024

8 Października 2024

8 Października 2024

8 Października 2024
Instrukcje serwer
- serwer Sony
- serwer Lenovo
- serwer Gigabyte
- serwer Acer
- serwer Technics
- serwer Hikvision
- serwer Fujitsu
- serwer Conceptronic
- serwer StarTech.com
- serwer Asus
- serwer Medion
- serwer TRENDnet
- serwer MSI
- serwer Toshiba
- serwer D-Link
- serwer ATen
- serwer APC
- serwer HP
- serwer Tripp Lite
- serwer Cisco
- serwer Moxa
- serwer Synology
- serwer Lindy
- serwer ZyXEL
- serwer Dell
- serwer Linksys
- serwer Digitus
- serwer Vimar
- serwer Netgear
- serwer Black Box
- serwer ELAC
- serwer Intellinet
- serwer HGST
- serwer Revox
- serwer Naim
- serwer SEH
- serwer Planet
- serwer NEC
- serwer LevelOne
- serwer Digi
- serwer Axis
- serwer Asrock
- serwer Abus
- serwer Rocstor
- serwer Western Digital
- serwer Smart-AVI
- serwer Promise Technology
- serwer QNAP
- serwer Chenbro Micom
- serwer Allnet
- serwer Veritas
- serwer IStarUSA
- serwer Silverstone
- serwer Ernitec
- serwer AVerMedia
- serwer Atlona
- serwer Gefen
- serwer Hanwha
- serwer Quantum
- serwer Blackmagic Design
- serwer Kathrein
- serwer Eaton
- serwer Monacor
- serwer Sonnet
- serwer In Win
- serwer Teo
- serwer Megasat
- serwer Areca
- serwer Kramer
- serwer KanexPro
- serwer Raritan
- serwer AMX
- serwer C2G
- serwer Acti
- serwer Sitecom
- serwer Maxdata
- serwer Matrox
- serwer Flir
- serwer Buffalo
- serwer GeoVision
- serwer LaCie
- serwer Valcom
- serwer Asustor
- serwer Intel
- serwer Fantec
- serwer Freecom
- serwer Seagate
- serwer Iomega
- serwer Luxman
- serwer Ibm
- serwer Provision ISR
- serwer TAIDEN
- serwer SIIG
- serwer Advantech
- serwer Extron
- serwer Avocent
- serwer Teradek
- serwer Silex
- serwer Sun
- serwer MvixUSA
- serwer Dual Bay
- serwer Raidsonic
- serwer EMC
- serwer Infortrend
- serwer Opengear
- serwer G-Technology
- serwer EXSYS
- serwer Middle Atlantic
- serwer Mr. Signal
- serwer Atlantis Land
- serwer Lantronix
- serwer NETSCOUT
- serwer Mobotix
- serwer Origin Storage
Najnowsze instrukcje dla serwer

9 Kwietnia 2025

2 Kwietnia 2025

2 Kwietnia 2025

2 Kwietnia 2025

28 Marca 2025

28 Marca 2025

28 Marca 2025

10 Marca 2025

10 Marca 2025

10 Marca 2025