Instrukcja obsługi Steren 550-010

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Steren 550-010 (4 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
R
Manufactured by:
Steren Electronics International, LLC
8675 Miralani Drive, San Diego, CA 92126
1-800-266-3333
www.steren.com
Fast Media
Home Network
Systems
Fast Media
Home Network
Systems
Installation
Guide
Installation
Guide
550-010
Fast Media
Telephone/TV Hub Module
61/2˝ (W) x 43/4˝ (H) x (D)
550-010Manual.qxd 7/6/04 3:28 PM Page 1
R
Fast Media Home Network Systems Revised 06/04
2
FastHome
550-010 Telephone/TV Hub Module Installation Guide
AC/D C A DAPT OR
MODEL: MX 12150-4113
IN PU T:
110V~50/60H z
OUTPUT: 1
5V----- -500mA
MADE IN CHI NA
-+
1 2 3 456
550-010Video Telcom M
aster Modul
e
OUT
RJ3IX
4
3
2
1
TM
INPUT
OUTPUT
1
4
2
5
3
6
POWER
LED
FROM
TELCOM
WAR
NING
!
Welcome to the FastHomeSeries
Thank you for purchasing this product, part of the FastHomeSeries of Fast Media Home
Network Systems by Steren. You have made an excellent choice for the homeowner. The
FastHomeSeries of enclosures and modules provide a quality control center for the wiring
of cable TV, phone/fax/modem, Ethernet, security, sound system and other voice, video, data
and audio devices. Installation is easy and requires only basic tools. By following the instruc-
tions in this guide, you will ensure the proper installation of the FastHomemodule.
Product Description
From a centralized location, the Fast Media Telephone/TV Hub Module distributes four
incoming phone/fax/modem lines and also combines and distributes two incoming cable
TV lines to six rooms. The module allows for the insertion of security camera feed using
the RF Modulator Module (550-080) and features an RJ-31X security system connection.
This module also includes a 9VDC, 300mA power supply. All FastHomemodules feature
18-gauge cold rolled steel construction for excellent RFI shielding.
Contents of Package
1. Fast Media Telephone/TV Hub Module
2. 9VDC power supply
3. Installation manual
Tools for Module Installation and Wiring
1. Wire stripper
2. Punchdown tool
3. Personal protective equipment
Introduction
Specifications:
TV Splitter:
Insertion Loss: 0.0dB 1dB±
Return Loss: 10dB min.
Isolation: 20dB min.
Telephone Hub:
Complies with TIA/EIA 568
CAT5 Standards
About Steren Electronics
Based in San Diego, Steren
has been a leading component
manufacturer for nearly 50 years.
With more than 2,000 items
in our catalog, we supply inter-
connect products and electronics
accessories for home and
commercial use.
The FastHomeSeries
of Fast Media Home Network
Systems are produced with
superior design and engineering,
high-quality materials and excep-
tional manufacturing processes,
attributes that are synonymous
with the Steren name.
Safety Instructions
Read these safety instructions before installing this module and follow them carefully.
Keep these instructions handy and refer to them when working on the module.
Always wear the necessary personal protective gear and follow all
basic precautions and safety procedures when working with wires
and electrical equipment, using power tools or working in unfinished
construction areas.
Use caution when handling this module. Be careful not to drop the
module because this could affect the performance and/or damage
the module.
Take extra precautions when working with cables, wires and tools.
Do not install cables and wires that appear to be damaged. Avoid
kinking cables and wires during installation.
Be careful when using tools that might touch exposed wires or live
electrical contacts.
To prevent electric shock: 1) do not touch uninsulated wires and terminals that
may still be connected to a live circuit; 2) do not install wires or electrical equipment
during a lightning storm; 3) do not install wires or electrical equipment or their
enclosures near water or locations where water is used (in the kitchen, bathroom,
laundry room, swimming pool, etc.); 4) do not install electrical components or equip-
ment in wet areas, unless specifically rated for moisture.
Make sure all wires in the modules are properly connected or terminated.
Standard 110
Punchdown Tool
550-010Manual.qxd 7/6/04 3:28 PM Page 2
Fast Media Home Network Systems Revised 06/04
3
FastHome
550-010 Telephone/TV Hub Module Installation Guide
R
Pre-Installation Instructions
1. After the enclosure has been mounted, determine which modules will be inserted. On a
sheet of paper, diagram the location where each module will be placed. An expansion
module should be placed close to the module with which it interfaces.
2. On the diagram, identify the origin and destination of each cable. Make sure the module
serving each device is safely within a 100ft/30m distance.
Installation Instructions
Note: Do not connect the DC power supply to a power outlet until all wiring has been completed.
1. Identify the enclosure location on which the module will be mounted.
2. Mount the module by inserting the nylon pins into the holes in back of the enclosure and
pressing the pins in. Make sure that the pins are firmly seated and the module is secure.
Wiring Instructions
Note: Module wiring should only be performed by a experienced, licensed electrician. Make
sure all power has been shut off to the equipment and there is no live circuit. Route all cables
through the knock-out holes and bundle with tie wraps or cable straps to ensure safe and
long-lasting connections.
Telephone Hub:
1. Route Category 5 phone cables from the network interface device at the phone companys
demarcation point to the module.
2. Using a wire stripper, strip off about 2 of the cable to expose the wires. Separate the four˝
wire pairs.
3. Using a standard 110 punchdown tool, terminate the tip and ring wires at the “ ”from telcom
side of the telephone hub. Match each wire pair with the color codes on the IDC block
(white/blue: blue pair in line one; white/orange: orange pair in line two; white/green: green
pair in line three; white/brown: brown pair in line four).
4. Perform the stripping and punchdown function for wires at the “ ”output side of the telephone
hub, for 1-6 locations in the home.
5. Tag each cable in the module with its point of destination.
6. Route the cables from the hub to the phone/fax/modem locations in the home and termi-
nate accordingly.
7. Connect the 9VDC power supply cord to the power input jack.
Security System:
This FastHomemodule offers a connection to the security system that
can override any phone in use and alert the security service provider of an
emergency. To enable this function, connect the security system cable to
the modules RJ-31X jack located below the expansion port. (Refer to the
manual from the security system manufacturer for specific instructions and
safety information.)
TV Hub:
1. Connect F-terminated coaxial cable inputs from the cable TV incoming feed and, if insert-
ing security camera feed, the Fast Media RF Modulator Module (550-080) onto the ports
on the input side of the TV hub.
2. Connect an F-terminated coaxial cable onto each of 1-6 outputs on the output side of
the hub.
3. Route the cables from the hub to the TV set locations in the home and terminate with
75-Ohm F-connectors.
4. Place 75-Ohm termination caps over unused TV hub ports to improve video reception.
5. Connect the 9VDC power supply cord to the power input jack.
Installation
Sample configuration for telephone,
audio/video, security and Ethernet.
For More Information
about FastHomeand
Fast Media Home Network
Systems, contact:
Steren Electronics International, LLC
8675 Miralani Drive
San Diego, CA 92126
1-800-266-3333
www.steren.com
Copyright 2004 ©
Steren Electronics International, LLC
Printed in China
550-010Manual.qxd 7/6/04 3:28 PM Page 3

Specyfikacje produktu

Marka: Steren
Kategoria: przełącznik
Model: 550-010

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Steren 550-010, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje przełącznik Steren

Steren

Steren SEL-400 Instrukcja

22 Września 2024
Steren

Steren 550-010 Instrukcja

22 Września 2024

Instrukcje przełącznik

Najnowsze instrukcje dla przełącznik

Netgear

Netgear GS110TPP Instrukcja

15 Października 2024
ZyXEL

ZyXEL SFP-LHX1310-40-D Instrukcja

14 Października 2024
Tripp Lite

Tripp Lite B005-DPUA4 Instrukcja

11 Października 2024
Lancom

Lancom CS-8132F Instrukcja

9 Października 2024
Lancom

Lancom YS-7154CF Instrukcja

9 Października 2024
TP-Link

TP-Link Festa FS328G Instrukcja

9 Października 2024
Totolink

Totolink SW24DM Instrukcja

9 Października 2024
Totolink

Totolink SW1008P Instrukcja

9 Października 2024
Totolink

Totolink SW24G2 Instrukcja

9 Października 2024
Cudy

Cudy FS1006P Instrukcja

9 Października 2024